ISO 10816-1
Machine Vibration Evaluation on Non-Rotating Parts
ISO 10816-1 provides general principles and procedures for measuring vibration on non-rotating parts of machines to assess mechanical condition and reliability. This foundational standard establishes measurement methodology, instrumentation requirements, and evaluation zones applicable across diverse machine types. Manufacturers, service providers, and plant operators use this test to monitor equipment health and prevent unexpected failures. Accreditation ensures consistent, comparable vibration measurements that support predictive maintenance strategies and machine acceptance criteria.
What it measures
- Vibration velocity in mm/s (RMS and peak)
- Frequency range (typically 10–1000 Hz)
- Vibration magnitude in vertical, horizontal directions
- Machine operating condition classification
- Alarm and alert threshold zones
🇩🇪
DIN EN ISO 10816-3
🇬🇧
BS EN ISO 10816-3
🇫🇷
NF EN ISO 10816-3
🇮🇹
UNI EN ISO 10816-3
🇪🇸
UNE EN ISO 10816-3
🇳🇱
NEN EN ISO 10816-3
🇩🇪
DIN EN ISO 13373-1
🇬🇧
BS EN ISO 13373-1
🇫🇷
NF EN ISO 13373-1
🇮🇹
UNI EN ISO 13373-1
🇪🇸
UNE EN ISO 13373-1
🇳🇱
NEN EN ISO 13373-1
1,817
Accredited labs
19
Countries
Showing 676–700 of 1,817 labs
(HSG 264, 2012)
and Appx. 3 of HSG 227 (2004))
Executive guides HSG 264 (2012)
Absolutdruck p
abs
> 41 bar
Negativer und
positiver Überdruck
+ 3 more
Heywood Williams Components
Active
DIN EN 1026
DIN EN 12046-2
BS 6375-1:2015 + A1:2016 and the
DIN EN 1027
DIN EN 1629
+ 3 more
Hi Gain
Active
MIL-STD-883G METHOD 3015.7
MIL-STD-883H METHOD 3015.8
MIL-STD-883J METHOD 3015.9
Hohenstein Laboratories
Active
DIN 53160
DIN 54034
DIN 54056
DIN EN 20105-A02
DIN EN 20105-N01
+ 3 more
Taupunkttemperatur
thermometer, -80 °C bis
Railway braking — urban guided transport
> -35 °C bis
Temperatur- −35 °C bis
+ 3 more
Horiba Europe
Active
0,6 bar
ver Überdruck p e *
Absolutdruck p abs 100 mbar
> 70 mbar
Gaskonzentration
+ 3 more
Horiba MIRA
Active
IEC 60068-2-14
IEC 60068-2-1
DIN EN 60068-2-14
IEC 60068-2-2
DIN EN IEC 60068-2-38
+ 3 more
Hottinger Brüel & Kjaer
Active
Übertragungsmaß von
Messmikrofonen oder
Freifeld-Leerlauf- 20 Hz
Freifeld -Übertragungsmaß
Vorverstärker, nach IEC
+ 3 more
DIN ISO 5667-5 (A 14)
DIN EN ISO 19458 (K 19)
DIN 19643-1
DIN EN ISO 7887 (C 1)
DIN 38404-C 4
+ 3 more
Hydrodata
Active
DIN EN ISO 5667-1 (A 4)
DIN 38402-A 12
DIN 38402-A 13
DIN 38402-A 15
DIN EN ISO 5667-3 (A 21)
+ 3 more
Hydrotechnik
Active
Negativer und
Positiver Überdruck p e
> 0,015 bar
Überdruck p
(ein- oder mehrgängige
+ 3 more
HygCen Germany
Active
DIN EN ISO 10993-1
DIN EN ISO 10993-5
DIN EN ISO 17405
ISO 10993-23
DIN EN ISO 10993-18
+ 3 more
Hygiene Nord
Active
DIN EN ISO 10993-5
DIN EN ISO 10993-1
DIN EN ISO 11737-2
DIN EN 1040
DIN EN IEC 60601-2-75
+ 3 more
Hygiene-Institut AYSID
Active
DIN 1946-4
DIN EN 13098
DIN EN ISO 17141
ISO 14644-3
DIN 12980
+ 1 more
Innen- und Tiefenmaße
Konventioneller
Wägewert/
Massenormale
Festkörpervolumen
+ 3 more
I2 Analytical
Active
staining based on HSG 248.
(HSG 248) – 2021
(PCM) based on HSG 248
A007B based on BS EN15051-2:2013 +1:2016
DIN EN 12457-3
+ 3 more
IANESCO
Active
DIN EN ISO 17294-2
ISO 7086-2:2000
DIN EN ISO 14403-2
DIN EN ISO 13395
NF T 90-412
+ 3 more
IEC 60068-2-1
IEC 60068-2-2
DIN EN 60068-2-30
IEC 60068-2-30
DIN EN IEC 60068-2-38
+ 3 more
Messgeräte 0,01 V
Messgeräte 0,33 V
3,3 V
330 V
Quellen 0,01 V
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN EN 61800-5-1: 2017
IDIADA AUTOMOTIVE TECHNOLOGY
Active
DIN EN 1385
EN 17092-1:2020
DIN EN ISO 5077
EN 1317-1
DIN EN ISO 13688
+ 3 more
IFB Eigenschenk
Active
DIN EN ISO 17892-2
DIN EN ISO 17892-3
DIN EN ISO 17892-4
DIN 18121-2
DIN 18125-2
+ 3 more
HbA1c
Vitamin A
Vitamin B1
Vitamin B2
Vitamin B6
+ 3 more
No matching labs found.