ISO 10816-3
Industrial Machine Vibration Assessment (>15 kW)
ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.
What it measures
- Vibration velocity in mm/s (RMS) on bearing pedestals
- Measurement at specified speed ranges and operating conditions
- Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
- Vertical and horizontal vibration components
- Trend analysis and transient response
🇩🇪
DIN EN ISO 10816-1
🇬🇧
BS EN ISO 10816-1
🇫🇷
NF EN ISO 10816-1
🇮🇹
UNI EN ISO 10816-1
🇪🇸
UNE EN ISO 10816-1
🇳🇱
NEN EN ISO 10816-1
🇩🇪
DIN EN ISO 20816-3
🇬🇧
BS EN ISO 20816-3
🇫🇷
NF EN ISO 20816-3
🇮🇹
UNI EN ISO 20816-3
🇪🇸
UNE EN ISO 20816-3
🇳🇱
NEN EN ISO 20816-3
1,817
Accredited labs
19
Countries
Showing 351–375 of 961 labs
Liste aller Untersuchungsverfahren
Webpräsenz des Medizinischen Laboratoriu
CDT
Ampicilin
Cefepim
+ 3 more
AMA M2-3E IgG
Anti-CCP (Cyclische Citrullin
Antikörper) IgG
Anti-dsDNS-NCX IgG
Anti- Transglutaminase
+ 3 more
Kneissl Messtechnik
Active
Koordinatenmessgeräte geräte mit einem
Messprojektoren einer Raumdiagonalen
Messmikroskope ≤ 600 mm
verwendete Abkürzungen:
UIC-Mb 541-03
UIC-541-08
UIC-541-6
DIN 27205-9
DIN EN 15355
+ 3 more
Kolb & Baumann
Active
Parallelendmaße 0,5 mm bis
DIN EN ISO 3650:1999
Parallelendmaße aus 0,5 mm bis
Keramik oder
Wolframkarbid nach
+ 3 more
Kordt Messtechnik
Active
(ein- und mehrgängige
zylindrische Außen- und
geradlinigen Flanken und
symmetrischem Profil sowie
positiven Flankenwinkeln)
+ 3 more
Kostal Kontakt Systeme
Active
DIN 40050-9
IEC 60068-2-2
IEC 60068-2-6
DIN EN IEC 60068-2-13
DIN EN 60068-2-14
+ 3 more
Thrombozytenfunktion
Amiodaron/Desethylamiodaron
Cotinin
Cyclosporin A
Everolimus
+ 3 more
Albumin
Alkohol
ALP
Anti-Faktor Xa (Fragmin)
AT3
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN EN 13487
DIN 45635-46
+ 2 more
Eindringkörper für 75°
Sound system equipment — speech transmis
Länge der
Schnittlinien *
Vergrößerungsnormale Abflachung bis 300
+ 3 more
Durchfluss von Gasen 17 mL/s
transferstandards
Strömungswiderstand 5 mL/min
15,0 mL/min
Laminar Flow Elemente 17 mL/min
+ 3 more
Kötter Consulting Engineers
Active
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN EN 61400-11
ISO 9613-2
Messschieber für Außen-, 0 mm
Innen- und Tiefenmaße
> 300 mm
Tiefenmessschieber 0 mm
Höhenmessschieber 0 mm
+ 3 more
LABCO
Active
ASTM D 638
ASTM D 1004
DIN EN 50178: 1998
ISO 21527-2
DIN EN ISO 527-3
+ 3 more
LABUS Testlab
Active
DIN EN IEC 60068-2-11
DIN EN 60068-2-14
DIN EN 60068-2-18
IEC 60068-2-29
DIN EN 60068-2-30
+ 3 more
LADR GmbH MVZ Nord-West
Active
10-Hydroxycarbazepin (MHD)
Amiodaron, Desmethylamiodaron
Clozapin, Norclozapin
Cyclosporin A
Amiodaron, Desethylamiodaron
+ 3 more
HbA1c
Basophile
Eosinophile
Erythrozyten
Hämatokrit
+ 3 more
HbA1c
HCG qualitativ
Erythrozyten
Granulozyten basophil
Granulozyten eosinophil
+ 3 more
HbA1c
Retikulozyten
Leukozyten
Kleines Blutbild
Großes Blutbild =
+ 3 more
HbA1c
Zellzahl
Blutbild groß
Blutbild klein
Retikulozyten
+ 3 more
Thrombozytenfunktionstest
2-Desoxypipradol (2-DPMP)
2-oxo-3-hydroxy-LSD
3.4-DMMC
3-Fluormethcathinon
+ 3 more
HbA1c
Basophile Granulozyten
Eosinophile Granulozyten
Erythrozyten
Hämatokrit
+ 3 more
Liste aller Untersuchungsverfahren
Webpräsenz des Medizinischen Laboratoriu
HbA1c
Basophile
Eosinophile
+ 3 more
No matching labs found.