ISO 10816-3

Industrial Machine Vibration Assessment (>15 kW)

ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.

What it measures

  • Vibration velocity in mm/s (RMS) on bearing pedestals
  • Measurement at specified speed ranges and operating conditions
  • Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
  • Vertical and horizontal vibration components
  • Trend analysis and transient response
🇩🇪 DIN EN ISO 10816-1 🇬🇧 BS EN ISO 10816-1 🇫🇷 NF EN ISO 10816-1 🇮🇹 UNI EN ISO 10816-1 🇪🇸 UNE EN ISO 10816-1 🇳🇱 NEN EN ISO 10816-1 🇩🇪 DIN EN ISO 20816-3 🇬🇧 BS EN ISO 20816-3 🇫🇷 NF EN ISO 20816-3 🇮🇹 UNI EN ISO 20816-3 🇪🇸 UNE EN ISO 20816-3 🇳🇱 NEN EN ISO 20816-3
1,591 Accredited labs
17 Countries

Showing 326–350 of 1,591 labs

DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
ENAC LC10.204 Fuenlabrada, ES
0 mV  U < 330 mV 330 mV  U < 3,3 V 3,3 0 mV  U < 120 mV 120 mV  U < 1,2 V 1,2 0 A  I  330 A 330 A < I  3,3 mA 3, 20 A  I  1025 A 20 A  I  1025 A F = 50 Hz + 3 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile
COFRAC 1-7430 Marchaux-Chaudefontaine, FR
DIN EN 60068-2-64 DIN EN-60068-2-1 DIN EN 60068-2-78 DIN EN-60068-2-2 DIN EN 60068-2-14 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-PL-11035-06-00 Essen, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
ENAC LC10.254 Sevilla, ES
50 ∙ 10-9 mol/mol ≤ C ≤ 237 · 10-9 mol/m 30∙ 10-9 mol/mol ≤ C ≤ 500 ∙ 10-9 mol/mo 50 ∙ 10-9 mol/mol ≤ C ≤ 1000 · 10-9 mol/ 50 ∙ 10-9 mol/mol ≤ C ≤ 237∙ 10-9 mol/mo 0,5 ∙ 10-9 mol/mol ≤ C ≤ 15 ∙ 10-9 mol/m + 1 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
UKAS 4303 Ammanford, GB
1) MS08P based on BS EN ISO MS02P based on BS EN ISO MS03P based on BS EN ISO MS06P based on BS EN ISO MF07P based on BS EN ISO + 3 more
View Profile
DAkkS D-K-23327-01-01 Bad Camberg, DE
Metrologic Group GmbH, nalen von: Wernau, D Neuss, D ≤ 1515 mm Wetzlar, D S.p.A., Turin, I + 3 more
View Profile
ACCREDIA 02012 Roma, IT
ETSI EN 319 412 ETSI EN 319 401 ETSI EN 319 411-2 ETSI EN 319 411-1
View Profile
DAkkS D-PL-17009-06-00 Wiesbaden, DE
DIN EN 60950-1 EN IEC 62368-1 DIN EN 60204-1 DIN EN 60825-1 DIN EN 61010-1 + 3 more
View Profile
DAkkS D-PL-17009-05-01 Haan, DE
DIN 58214 DIN EN 15443 Vitamin 812 DIN EN ISO 3960 ASTM D 3343 + 3 more
View Profile

No matching labs found.

Industries

Thermal power stations Industrial compressors and pumps Paper and pulp manufacturing Turbomachinery and rotating equipment Process plant operations

Related Standards

  • ISO 10816-1 Mechanical vibration—Evaluation of machine vibration by measurements on non-rotating parts—Part 1: General guidelines
  • ISO 20816-3 Mechanical vibration—Measurement and evaluation of vibration of rotating machinery—Part 3: Industrial machines with nominal power above 15 kW and nominal speeds between 120 r/min and 15 000 r/min when measured on the rotating shaft
  • API 670 Machinery Protection Systems—Fourth Edition