ISO 7626-2

Experimental Modal Analysis – Single-Point Excitation

ISO 7626-2 describes procedures for experimental modal analysis using single-point, single-axis excitation to characterise the dynamic properties and natural frequencies of structures and machines. This test method captures frequency response functions and mode shapes essential for structural design validation, vibration control, and fault diagnosis. Aerospace, automotive, civil engineering, and machinery manufacturers use modal analysis to refine designs and understand dynamic behaviour under operational loads. Accreditation ensures rigorous application of measurement protocols and data quality standards supporting engineering confidence in structural performance predictions.

What it measures

  • Frequency response functions (FRF) over specified frequency range
  • Natural frequencies (resonances) and modal damping ratios
  • Mode shapes and structural deflection patterns
  • Coherence and measurement quality indicators
  • Dynamic stiffness and impedance characteristics
🇩🇪 DIN EN ISO 7626-1 🇬🇧 BS EN ISO 7626-1 🇫🇷 NF EN ISO 7626-1 🇮🇹 UNI EN ISO 7626-1 🇪🇸 UNE EN ISO 7626-1 🇳🇱 NEN EN ISO 7626-1 🇩🇪 DIN EN ISO 7626-5 🇬🇧 BS EN ISO 7626-5 🇫🇷 NF EN ISO 7626-5 🇮🇹 UNI EN ISO 7626-5 🇪🇸 UNE EN ISO 7626-5 🇳🇱 NEN EN ISO 7626-5
1,591 Accredited labs
17 Countries

Showing 476–500 of 885 labs

DAkkS D-ML-13245-01-01 Dresden, DE
angeborener Chromosomensatz Nummerische Veränderungen Chromosomen 13, 18, 21, X und ldentifizierung kleinster chromosomaler/numerischer + 3 more
View Profile
DAkkS D-ML-13245-02-00 Dresden, DE
Multiplate-Analyse (TRAP, ADP) Thrombozytenaggregation Born) Organische Säuren (Profil) Metanephrin, Normetanephrin + 3 more
View Profile
DAkkS D-ML-22497-01-00 Greifswald, DE
Familiäre Adenomatöse Polyposis Syndrome (APC, MUTYH) STK11, SMAD4 ), TruRisk® -Panel [SNV, CN Familiäre Polyposis-Syndrome [FAP] (APC, MUTYH) + 3 more
View Profile
DAkkS D-ML-17445-01-00 Dessau-Roßlau, DE
WBC (Leukozyten) RBC (Erythrocyten) HGB (Hb) HCT (Hk) PLT (Thrombozyten) + 3 more
View Profile
DAkkS D-ML-18902-01-00 Rostock, DE
Chromosomensatz (angeboren) Chromosomensatz (erworben) Adrenogenitales Syndrom Angelman-Syndrom (15q11-Region, UBE3A) Mikrodeletionen; AZFa-c) + 3 more
View Profile
DAkkS D-ML-13237-01-00 Raubling, DE
HbA1c Basophile, automatisch Eosinophile, automatisch Erythrozyten, automatisch Leukozyten, automatisch + 3 more
View Profile
DAkkS D-ML-19175-01-00 Erfurt, DE
HbA1c Hämatokrit Hämoglobin Leukozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-18008-01-00 Raunheim, DE
HbA1c Blutbild, groß (Blutbild klein Hämoglobin, Hämatokrit, MCH, MCHC) Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-13182-01-00 Essen, DE
Leukozyten Erythrozyten Thrombozyten Hämatokrit MCV + 3 more
View Profile
DAkkS D-ML-13238-01-01 Göttingen, DE
Obligat anaerobe Bakterien Grampositive aerobe und anaerobe Kokken Enterokokken Mikrokokken + 3 more
View Profile
DAkkS D-ML-13445-01-01 Wernigerode, DE
automatische Zelldifferenzierung Erythrozyten Leukozyten Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-K-15048-01-01 Allmersbach im Tal, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße > 100 mm Messschieber für Außen-, 0 mm + 3 more
View Profile
DAkkS D-K-21664-01-01 Radebeul, DE
− Beschleunigung Beschleunigung 0,1 m/s² zu 25 mV bis 1 V (Sekundär) sinusförmig Schwingungsaufnehmer + 3 more
View Profile

Metrolution

Active
DAkkS D-K-21403-01-01 Aichhalden, DE
Metrosoft CM, Software einer Raumdiagona AG, Chur, CH ≤ 3333 mm Oberkochen, D GmbH, Wetzlar, D AG, Chur, CH ≤ 7500 mm
View Profile
DAkkS D-K-19120-01-01 Gießen, DE
Flüssigkeitsvolumen * Kolbenhubpipetten Manuell betätigte spritzen Mehrfachdispenser + 3 more
View Profile
DAkkS D-K-15086-01-01 Wedel, DE
- Gleichspannung Messverstärker > 120 mV > 1 V > 12 V > 1000 V + 3 more
View Profile
DAkkS D-K-19573-01-00 Gefell, DE
Akustische Messgrößen Messmikrofone nach (DIN EN 61094-4:1996) Schalldruckpegel (Druck) Empfangsübertragungsmaß + 3 more
View Profile
DAkkS D-K-20451-01-00 Bovenden, DE
Konventioneller Wägewert/ Massenormale Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO + 3 more
View Profile
DAkkS D-ML-19288-01-00 Stuttgart, DE
Bacillus cereus Toxin Clostridium perfringens Salmonella spp. Shigella spp. Staphylococcus aureus Toxin + 3 more
View Profile
DAkkS D-K-15096-01-00 Neuss, DE
Parallelendmaße 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße > 10 mm Parallelendmaße > 100 mm + 3 more
View Profile
DAkkS D-K-21161-01-01 Esslingen, DE
Gleichspannung 3 mV Messgeräte 10 mV > 100 mV > 220 mV > 11 V + 3 more
View Profile
DAkkS D-K-11292-01-00 Buchen Odenwald, DE
Temperatur 50 °C Railway brake handbooks (UIC 547) 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-PL-19306-01-00 Oppenweiler, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-3: 2006 VDE 0847-4-3 IEC 61000-4-4: 2012 + 3 more
View Profile
DAkkS D-PL-19432-01-01 München, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-ML-20225-01-00 Minden, DE
Differentialblutbild Kleines Blutbild (maschinell) Thrombozyten Unreife Thrombozyten (IPF) Urinsediment (maschinell) + 3 more
View Profile

No matching labs found.

Industries

Aerospace and defence engineering Automotive design and validation Civil engineering and bridge design Heavy machinery and equipment development Vibration and noise control consulting

Related Standards

  • ISO 7626-1 Vibration and shock—Experimental determination of mechanical mobility—Part 1: Basic definitions and transducers
  • ISO 7626-5 Vibration and shock—Experimental determination of mechanical mobility—Part 5: Coupling of mechanical mobility measurement instrumentation
  • ISO 6954 Mechanical vibration and shock—Acceleration transducers—Specifications for laboratory standard instruments

Other Test Methods

0 labs selected