ISO 7626-5
Experimental Modal Analysis Using Impact Excitation
This test method characterises the dynamic properties of structures through experimental modal analysis using impact hammer excitation. The method measures natural frequencies, damping ratios, and mode shapes by striking the structure and recording the resulting vibration response. It is widely used in aerospace, automotive, civil engineering, and mechanical equipment development to validate structural designs and identify potential vibration issues. Accreditation ensures proper instrumentation calibration, correct measurement methodology, and reliable data interpretation for safety-critical applications.
What it measures
- Natural frequencies (modal frequencies)
- Damping ratios (modal damping)
- Mode shapes (displacement patterns)
- Frequency response functions (FRF)
- Coherence and data quality metrics
🇩🇪
DIN EN ISO 7626-1
🇬🇧
BS EN ISO 7626-1
🇫🇷
NF EN ISO 7626-1
🇮🇹
UNI EN ISO 7626-1
🇪🇸
UNE EN ISO 7626-1
🇳🇱
NEN EN ISO 7626-1
🇩🇪
DIN EN ISO 7626-2
🇬🇧
BS EN ISO 7626-2
🇫🇷
NF EN ISO 7626-2
🇮🇹
UNI EN ISO 7626-2
🇪🇸
UNE EN ISO 7626-2
🇳🇱
NEN EN ISO 7626-2
1,591
Accredited labs
17
Countries
Showing 476–500 of 885 labs
angeborener Chromosomensatz
Nummerische Veränderungen
Chromosomen 13, 18, 21, X und
ldentifizierung kleinster
chromosomaler/numerischer
+ 3 more
Multiplate-Analyse (TRAP, ADP)
Thrombozytenaggregation
Born)
Organische Säuren (Profil)
Metanephrin, Normetanephrin
+ 3 more
Familiäre Adenomatöse Polyposis
Syndrome (APC, MUTYH)
STK11, SMAD4 ), TruRisk® -Panel [SNV, CN
Familiäre Polyposis-Syndrome [FAP]
(APC, MUTYH)
+ 3 more
WBC (Leukozyten)
RBC (Erythrocyten)
HGB (Hb)
HCT (Hk)
PLT (Thrombozyten)
+ 3 more
Chromosomensatz (angeboren)
Chromosomensatz (erworben)
Adrenogenitales Syndrom
Angelman-Syndrom (15q11-Region, UBE3A)
Mikrodeletionen; AZFa-c)
+ 3 more
HbA1c
Basophile, automatisch
Eosinophile, automatisch
Erythrozyten, automatisch
Leukozyten, automatisch
+ 3 more
HbA1c
Hämatokrit
Hämoglobin
Leukozyten
Thrombozyten
+ 3 more
HbA1c
Blutbild, groß (Blutbild klein
Hämoglobin, Hämatokrit, MCH, MCHC)
Retikulozyten
Thrombozyten
+ 3 more
Leukozyten
Erythrozyten
Thrombozyten
Hämatokrit
MCV
+ 3 more
Obligat anaerobe Bakterien
Grampositive aerobe und
anaerobe Kokken
Enterokokken
Mikrokokken
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Melutec Metrology
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 100 mm
Messschieber für Außen-, 0 mm
+ 3 more
− Beschleunigung
Beschleunigung 0,1 m/s²
zu 25 mV bis 1 V (Sekundär)
sinusförmig
Schwingungsaufnehmer
+ 3 more
Metrolution
Active
Metrosoft CM, Software einer Raumdiagona
AG, Chur, CH ≤ 3333 mm
Oberkochen, D
GmbH, Wetzlar, D
AG, Chur, CH ≤ 7500 mm
Mettler-Toledo
Active
Flüssigkeitsvolumen *
Kolbenhubpipetten
Manuell betätigte
spritzen
Mehrfachdispenser
+ 3 more
MeßTechnikNord
Active
- Gleichspannung
Messverstärker > 120 mV
> 1 V
> 12 V
> 1000 V
+ 3 more
Microtech Gefell
Active
Akustische Messgrößen
Messmikrofone nach
(DIN EN 61094-4:1996)
Schalldruckpegel (Druck)
Empfangsübertragungsmaß
+ 3 more
Minebea Intec Bovenden
Active
Konventioneller
Wägewert/
Massenormale
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
+ 3 more
Bacillus cereus Toxin
Clostridium perfringens
Salmonella spp.
Shigella spp.
Staphylococcus aureus Toxin
+ 3 more
Mitutoyo Deutschland
Active
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 10 mm
Parallelendmaße > 100 mm
+ 3 more
Mobiler Kalibrierdienst Fini
Active
Gleichspannung 3 mV
Messgeräte 10 mV
> 100 mV
> 220 mV
> 11 V
+ 3 more
Temperatur 50 °C
Railway brake handbooks (UIC 547)
1) In den CMC sind die erweiterten Messu
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
Mühlenkreiskliniken AöR Institut für Laboratoriumsmedizin, Transfusionsmedizin und Mikrobiologie
Suspended
Differentialblutbild
Kleines Blutbild (maschinell)
Thrombozyten
Unreife Thrombozyten (IPF)
Urinsediment (maschinell)
+ 3 more
No matching labs found.