ISO 7626-5
Experimental Modal Analysis Using Impact Excitation
This test method characterises the dynamic properties of structures through experimental modal analysis using impact hammer excitation. The method measures natural frequencies, damping ratios, and mode shapes by striking the structure and recording the resulting vibration response. It is widely used in aerospace, automotive, civil engineering, and mechanical equipment development to validate structural designs and identify potential vibration issues. Accreditation ensures proper instrumentation calibration, correct measurement methodology, and reliable data interpretation for safety-critical applications.
What it measures
- Natural frequencies (modal frequencies)
- Damping ratios (modal damping)
- Mode shapes (displacement patterns)
- Frequency response functions (FRF)
- Coherence and data quality metrics
🇩🇪
DIN EN ISO 7626-1
🇬🇧
BS EN ISO 7626-1
🇫🇷
NF EN ISO 7626-1
🇮🇹
UNI EN ISO 7626-1
🇪🇸
UNE EN ISO 7626-1
🇳🇱
NEN EN ISO 7626-1
🇩🇪
DIN EN ISO 7626-2
🇬🇧
BS EN ISO 7626-2
🇫🇷
NF EN ISO 7626-2
🇮🇹
UNI EN ISO 7626-2
🇪🇸
UNE EN ISO 7626-2
🇳🇱
NEN EN ISO 7626-2
1,591
Accredited labs
17
Countries
Showing 76–100 of 885 labs
Bundesministerium der Verteidigung Bundeswehrkrankenhaus Berlin Abteilung XVI Laboratoriumsmedizin
Active
NRBC-Normoblasten
Anteil unreifer Retikulozyten
Erythrozyten
DELTA-He
Leukozyten
+ 3 more
Blutungszeit PFA ADP
Blutungszeit PFA EPI
PFA-P2Y
Erythrozyten
Hämatokrit
+ 3 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
EN IEC 61000-4
DIN EN IEC 61000
VDE 0847-4
DIN EN 55016-2
DIN EN IEC 61000-6
+ 3 more
DIN EN ISO 898-1
DIN EN ISO 898-2
ISO 898-1
ISO 898-2
DIN EN ISO 6892-2
+ 3 more
/ Messgeräte
Radiometrie 100 µW/cm²
stärkemessgeräte
UV-A 365nm
Linearität der
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkürzungen:
CARTESY
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kraft
Railway vehicles — specific test require
Railway — traction effort and braking fo
+ 3 more
CETA Testsysteme
Active
Druck *
> –0,12 bar bis
negativer und positiver
Überdruck p e > –0,01 bar bis
> 0,03 bar bis
+ 3 more
CEcert
Active
IEC 61000-4-2: 2008
EN IEC 61000-4
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
+ 3 more
COAGUMED Gerinnungszentrum
Active
Thrombozytenaggregationstest
Blutbild mit Vordifferenzierung
Calcium
Natriumchlorid
Kalium
+ 3 more
- Gleichspannung
Quellen > 0,10 V
> 1 V
> 10 V
- Gleichstromstärke
+ 3 more
CSA Group Bayern
Active
DIN EN 55016-2
VDE 0877-16-2-1
VDE 0877-16-2-2
VDE 0877-16-2-3
EN IEC 61000-4
+ 3 more
CTK-Poliklinik
Active
Oligosaccharide
Chromatographie (Gaschromatograpie
Cannabinoide (THC-COOH)
Amphetamine
Opiate
+ 3 more
Carl Zeiss
Active
DIN EN 60601-1
IEC 60601-1
DIN EN 60601-1-1
IEC 60601-1-1
IEC 80601-2-77
+ 3 more
Carl Zeiss IQS Deutschland
Active
Carl Zeiss Industrielle ≤ 3818 mm
Oberkochen, D
1) In den CMC sind die erweiterten Messu
Carl Zeiss Industrielle ≤ 20 m
Auswertesoftware Messvolumen mit
+ 3 more
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
CeGaT
Active
angeborener Chromosomensatz
(Imbalancen im Genom, (Duplikationen/Del
SNRPN-Region 15q11-13 UPD15
(UBE3A)
SMN1; Spinale Muskelatrophie
+ 3 more
Cenata
Active
Pränatales Screening auf
Chromosomenstörungen
(Trisomie 21, Trisomie 18, Trisomie
13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
Whole genome sequencing (WGS:
SNV, CNV/SV)
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
Coesfeld
Active
Kraft (WPM)
Belastungseinrichtungen von
Werkstoffprüfmaschinen
Länge (WPM) 0,5 mm
messeinrichtungen von
+ 3 more
Messgeräte 0,001 V
> 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
No matching labs found.