ISO 7626-5
Experimental Modal Analysis Using Impact Excitation
This test method characterises the dynamic properties of structures through experimental modal analysis using impact hammer excitation. The method measures natural frequencies, damping ratios, and mode shapes by striking the structure and recording the resulting vibration response. It is widely used in aerospace, automotive, civil engineering, and mechanical equipment development to validate structural designs and identify potential vibration issues. Accreditation ensures proper instrumentation calibration, correct measurement methodology, and reliable data interpretation for safety-critical applications.
What it measures
- Natural frequencies (modal frequencies)
- Damping ratios (modal damping)
- Mode shapes (displacement patterns)
- Frequency response functions (FRF)
- Coherence and data quality metrics
🇩🇪
DIN EN ISO 7626-1
🇬🇧
BS EN ISO 7626-1
🇫🇷
NF EN ISO 7626-1
🇮🇹
UNI EN ISO 7626-1
🇪🇸
UNE EN ISO 7626-1
🇳🇱
NEN EN ISO 7626-1
🇩🇪
DIN EN ISO 7626-2
🇬🇧
BS EN ISO 7626-2
🇫🇷
NF EN ISO 7626-2
🇮🇹
UNI EN ISO 7626-2
🇪🇸
UNE EN ISO 7626-2
🇳🇱
NEN EN ISO 7626-2
1,591
Accredited labs
17
Countries
Showing 176–200 of 885 labs
EN 1317-1
EN 1317-2
EN 1317-3
DIN CEN/TS 1317-7
DIN CEN/TS 1317-9
+ 2 more
ISO 16750-3
DIN EN 60068-2-53
DIN EN 60068-2-64
ISO 20653
ISO 16750-4
+ 3 more
Frequenz
- Gleichspannung
Spannungsquellen 5 µV
1 mV
Messgeräte > 10 mV
+ 3 more
Abetalipoproteinämie (MTTP)
Achondroplasie (FGFR3)
Acoeruloplasminämie/Hypocoerulo
plasminämie (CP)
ACTH-unabhängige makronoduläre
+ 3 more
flexiblen Akkreditierungsbereich.
Beschleunigung * 10 m/s
Beschleunigungsaufnehmer
Beschleunigungsaufnehmer 10 m/s
digital (DTI)
+ 3 more
DIN EN ISO 8497
ISO 8301
ISO 8302
DIN EN 12664
DIN EN 12667
+ 3 more
Foundation Medicine
Active
(somatische genetische
ACVR1B, AKT1, AKT2, AKT3, ALOX12B, AMER1
GATA3, GATA4, GATA6, GID4, GNA11,GNA13,
CHEK2, CHIC2, CHN1, CIC, CIITA
IRF8, IRS2, ITK, JAK1, JAK2, JAK3, JARID
+ 3 more
- Gleichspannung
Messgeräte 0,33 V bis < 3,3 V
330 V
Quellen
> 0,1 V
+ 3 more
Kraft (WPM) 30 N
Vibration measuring instruments — test m
maschinen nach DIN
Kraft * 10 N
Acoustics — tonality assessment (DIN 456
+ 3 more
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-13
DIN EN 60068-2-14
DIN EN 60068-2-18
DIN EN 60068-2-30
+ 3 more
DIN EN IEC 60068-2-13
DIN EN 1159-3
DIN EN ISO 11357-2
DIN EN ISO 11357-3
DIN EN ISO 11357-4
+ 3 more
IEC 60891
IEC 60904-1
IEC TS 60904-1-2
IEC 60904-8
IEC 61215
+ 3 more
DIN EN ISO 717-1
DIN EN ISO 717-2
DIN EN ISO 10140-1
DIN EN ISO 10140-2
DIN EN ISO 10140-3
+ 3 more
Fraunhofer-Institut für Holzforschung, Wilhelm-Klauditz-Institut WKI Qualitätsprüfung und -bewertung
Active
DIN ISO 16000-3
DIN EN ISO 12460-3
DIN EN ISO 12460-4
DIN EN ISO 12460-5
100 HV 120
+ 3 more
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kurzschlussstrom
Solarmodule 16 mA
Gleichstrom- und Nieder- 10 mV
+ 3 more
G + B Kalibriertechnik
Active
Druck *
Absolutdruck Pabs
1 bar; 3 bar
Negativer und
positiver Überdruck
+ 3 more
GHMT
Active
DIN EN 50173-1
DIN EN 50173-2
DIN EN 50173-3
DIN EN 50173-4
DIN EN 50173-5
+ 3 more
DIN 51757
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN 237
+ 3 more
GMA-Werkstoffprüfung
Active
Koordinatenmesstechnik
Lasertracker*
0,5 m
1) In den CMC sind die erweiterten Messu
Bügelmessschrauben* 0 mm
+ 3 more
GMC-I Service
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
GPR Gesundheits- und Pflegezentrum Rüsselsheim gemeinnützige GmbH Institut für Laboratoriumsmedizin
Active
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAMMER
Active
DIN EN ISO 6683
ISO 3776-2
ISO 24135-1
DIN 45678
DIN EN ISO 7096
+ 3 more
No matching labs found.