ISO 2631-1
Whole-Body Vibration Exposure Assessment
ISO 2631-1 establishes methods for measuring and evaluating human exposure to whole-body vibration in vehicles, buildings, and occupational environments. This test quantifies vibration acceleration over frequency ranges relevant to human physiology, assessing potential health effects and comfort levels. Industries including transportation, construction, and industrial manufacturing rely on this assessment to ensure worker safety and product quality. Accreditation ensures reliable measurement data for compliance with occupational health directives and product design standards across Europe.
What it measures
- Vibration acceleration in three orthogonal axes (X, Y, Z)
- Frequency-weighted vibration magnitude (1–80 Hz)
- Daily vibration exposure index (A(8))
- Peak acceleration and crest factor
- Comfort and health effect zones
🇩🇪
DIN EN ISO 2631-2
🇬🇧
BS EN ISO 2631-2
🇫🇷
NF EN ISO 2631-2
🇮🇹
UNI EN ISO 2631-2
🇪🇸
UNE EN ISO 2631-2
🇳🇱
NEN EN ISO 2631-2
🇩🇪
DIN EN ISO 5349-1
🇬🇧
BS EN ISO 5349-1
🇫🇷
NF EN ISO 5349-1
🇮🇹
UNI EN ISO 5349-1
🇪🇸
UNE EN ISO 5349-1
🇳🇱
NEN EN ISO 5349-1
1,591
Accredited labs
17
Countries
Showing 176–200 of 885 labs
EN 1317-1
EN 1317-2
EN 1317-3
DIN CEN/TS 1317-7
DIN CEN/TS 1317-9
+ 2 more
ISO 16750-3
DIN EN 60068-2-53
DIN EN 60068-2-64
ISO 20653
ISO 16750-4
+ 3 more
Frequenz
- Gleichspannung
Spannungsquellen 5 µV
1 mV
Messgeräte > 10 mV
+ 3 more
Abetalipoproteinämie (MTTP)
Achondroplasie (FGFR3)
Acoeruloplasminämie/Hypocoerulo
plasminämie (CP)
ACTH-unabhängige makronoduläre
+ 3 more
flexiblen Akkreditierungsbereich.
Beschleunigung * 10 m/s
Beschleunigungsaufnehmer
Beschleunigungsaufnehmer 10 m/s
digital (DTI)
+ 3 more
DIN EN ISO 8497
ISO 8301
ISO 8302
DIN EN 12664
DIN EN 12667
+ 3 more
Foundation Medicine
Active
(somatische genetische
ACVR1B, AKT1, AKT2, AKT3, ALOX12B, AMER1
GATA3, GATA4, GATA6, GID4, GNA11,GNA13,
CHEK2, CHIC2, CHN1, CIC, CIITA
IRF8, IRS2, ITK, JAK1, JAK2, JAK3, JARID
+ 3 more
- Gleichspannung
Messgeräte 0,33 V bis < 3,3 V
330 V
Quellen
> 0,1 V
+ 3 more
Kraft (WPM) 30 N
Vibration measuring instruments — test m
maschinen nach DIN
Kraft * 10 N
Acoustics — tonality assessment (DIN 456
+ 3 more
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-13
DIN EN 60068-2-14
DIN EN 60068-2-18
DIN EN 60068-2-30
+ 3 more
DIN EN IEC 60068-2-13
DIN EN 1159-3
DIN EN ISO 11357-2
DIN EN ISO 11357-3
DIN EN ISO 11357-4
+ 3 more
IEC 60891
IEC 60904-1
IEC TS 60904-1-2
IEC 60904-8
IEC 61215
+ 3 more
DIN EN ISO 717-1
DIN EN ISO 717-2
DIN EN ISO 10140-1
DIN EN ISO 10140-2
DIN EN ISO 10140-3
+ 3 more
Fraunhofer-Institut für Holzforschung, Wilhelm-Klauditz-Institut WKI Qualitätsprüfung und -bewertung
Active
DIN ISO 16000-3
DIN EN ISO 12460-3
DIN EN ISO 12460-4
DIN EN ISO 12460-5
100 HV 120
+ 3 more
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kurzschlussstrom
Solarmodule 16 mA
Gleichstrom- und Nieder- 10 mV
+ 3 more
G + B Kalibriertechnik
Active
Druck *
Absolutdruck Pabs
1 bar; 3 bar
Negativer und
positiver Überdruck
+ 3 more
GHMT
Active
DIN EN 50173-1
DIN EN 50173-2
DIN EN 50173-3
DIN EN 50173-4
DIN EN 50173-5
+ 3 more
DIN 51757
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN 237
+ 3 more
GMA-Werkstoffprüfung
Active
Koordinatenmesstechnik
Lasertracker*
0,5 m
1) In den CMC sind die erweiterten Messu
Bügelmessschrauben* 0 mm
+ 3 more
GMC-I Service
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
GPR Gesundheits- und Pflegezentrum Rüsselsheim gemeinnützige GmbH Institut für Laboratoriumsmedizin
Active
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAMMER
Active
DIN EN ISO 6683
ISO 3776-2
ISO 24135-1
DIN 45678
DIN EN ISO 7096
+ 3 more
No matching labs found.