EN 13501-1
Reaction-to-Fire Testing
Reaction-to-fire tests classify the fire behaviour of construction products under the European Euroclass system (EN 13501-1). They measure ignitability, flame spread, heat release, smoke production, and flaming droplets. Euroclass classification is mandatory for construction products placed on the EU market under the Construction Products Regulation (CPR).
What it measures
- Ignitability (Class E -- single flame source)
- Flame spread and heat release rate (Classes B/C/D -- SBI test)
- Smoke production (s1/s2/s3 sub-classification)
- Flaming droplets (d0/d1/d2 sub-classification)
- Non-combustibility (Class A1/A2 -- furnace + calorimeter)
🇩🇪
DIN EN 13501-1
🇬🇧
BS EN 13501-1
🇫🇷
NF EN 13501-1
🇮🇹
UNI EN 13501-1
🇪🇸
UNE EN 13501-1
🇳🇱
NEN EN 13501-1
🇩🇪
DIN EN ISO 11925-2
🇬🇧
BS EN ISO 11925-2
🇫🇷
NF EN ISO 11925-2
🇮🇹
UNI EN ISO 11925-2
🇪🇸
UNE EN ISO 11925-2
🇳🇱
NEN EN ISO 11925-2
1,523
Accredited labs
17
Countries
Showing 51–75 of 818 labs
IEC 60945
IEC 61162-1
IEC 61162-2
IEC 61162-450
IEC 61162-460
+ 3 more
Radioaktivität 50 Bq/m³
Radon-222-
100 Bq/m³
tration in Luft
200 Bq/m³
+ 3 more
DIN EN 10200
DIN EN 24937
DIN EN ISO 9556
DIN EN 24935
DIN EN 24829-1
+ 3 more
DIN EN ISO 2808
DIN EN ISO 3219-2
DIN EN ISO 3838
DIN EN 933-1
DIN EN 933-4
+ 3 more
Conformity assessment — requirements for
Railway composite brake blocks — require
0,2 kN
0,4 kN
100 kN
+ 3 more
Bundesministerium der Verteidigung Bundeswehrkrankenhaus Berlin Abteilung XVI Laboratoriumsmedizin
Active
NRBC-Normoblasten
Anteil unreifer Retikulozyten
Erythrozyten
DELTA-He
Leukozyten
+ 3 more
Blutungszeit PFA ADP
Blutungszeit PFA EPI
PFA-P2Y
Erythrozyten
Hämatokrit
+ 3 more
DIN EN 1337-6
DIN EN ISO 1421
DIN EN ISO 3377-1
DIN EN ISO 3377-2
DIN EN ISO 13934-1
+ 3 more
/ Messgeräte
Radiometrie 100 µW/cm²
stärkemessgeräte
UV-A 365nm
Linearität der
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkürzungen:
CARTESY
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kraft
Railway vehicles — specific test require
Railway — traction effort and braking fo
+ 3 more
DIN EN ISO 6506-1
DIN EN ISO 6507-1
DIN EN ISO 6508-1
DIN EN ISO 3887
DIN EN ISO 9015-1
+ 3 more
CETA Testsysteme
Active
Druck *
> –0,12 bar bis
negativer und positiver
Überdruck p e > –0,01 bar bis
> 0,03 bar bis
+ 3 more
CEcert
Active
IEC 61000-4-2: 2008
EN IEC 61000-4
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
+ 3 more
CHEMAD
Active
DIN 38402-A 11
DIN 38402-A 12
DIN 38402-A 13
DIN EN ISO 5667-5 (A 15)
DIN 38402-A 30
+ 3 more
COAGUMED Gerinnungszentrum
Active
Thrombozytenaggregationstest
Blutbild mit Vordifferenzierung
Calcium
Natriumchlorid
Kalium
+ 3 more
- Gleichspannung
Quellen > 0,10 V
> 1 V
> 10 V
- Gleichstromstärke
+ 3 more
CSA Group Bayern
Active
DIN EN 55016-2
VDE 0877-16-2-1
VDE 0877-16-2-2
VDE 0877-16-2-3
EN IEC 61000-4
+ 3 more
CTK-Poliklinik
Active
Oligosaccharide
Chromatographie (Gaschromatograpie
Cannabinoide (THC-COOH)
Amphetamine
Opiate
+ 3 more
DIN EN ISO 13934-1
DIN EN ISO 13935-2
DIN EN ISO 13937-2
DIN EN ISO 13937-3
DIN EN 14682
+ 3 more
DIN EN 60695-2-11: 2014
DIN EN 60695-2-12: 2015
DIN EN 60695-2-13: 2015
VDA 270
DIN 75201
+ 3 more
Carl Zeiss
Active
DIN EN 60601-1
IEC 60601-1
DIN EN 60601-1-1
IEC 60601-1-1
IEC 80601-2-77
+ 3 more
Carl Zeiss IQS Deutschland
Active
Carl Zeiss Industrielle ≤ 3818 mm
Oberkochen, D
1) In den CMC sind die erweiterten Messu
Carl Zeiss Industrielle ≤ 20 m
Auswertesoftware Messvolumen mit
+ 3 more
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
No matching labs found.