EN 13501-1
Reaction-to-Fire Testing
Reaction-to-fire tests classify the fire behaviour of construction products under the European Euroclass system (EN 13501-1). They measure ignitability, flame spread, heat release, smoke production, and flaming droplets. Euroclass classification is mandatory for construction products placed on the EU market under the Construction Products Regulation (CPR).
What it measures
- Ignitability (Class E -- single flame source)
- Flame spread and heat release rate (Classes B/C/D -- SBI test)
- Smoke production (s1/s2/s3 sub-classification)
- Flaming droplets (d0/d1/d2 sub-classification)
- Non-combustibility (Class A1/A2 -- furnace + calorimeter)
🇩🇪
DIN EN 13501-1
🇬🇧
BS EN 13501-1
🇫🇷
NF EN 13501-1
🇮🇹
UNI EN 13501-1
🇪🇸
UNE EN 13501-1
🇳🇱
NEN EN 13501-1
🇩🇪
DIN EN ISO 11925-2
🇬🇧
BS EN ISO 11925-2
🇫🇷
NF EN ISO 11925-2
🇮🇹
UNI EN ISO 11925-2
🇪🇸
UNE EN ISO 11925-2
🇳🇱
NEN EN ISO 11925-2
1,523
Accredited labs
17
Countries
Showing 976–1,000 of 1,523 labs
DIN EN 1371-1
DIN 10955
DIN EN 61646
DIN EN 1230-1
EN 1230-2
+ 3 more
DIN EN ISO 15061 (D 34)
DIN EN 27888 (C 8)
DIN EN 1484 (H 3)
ISO 5667-21
DIN 38404-C 10
+ 3 more
Normec DETS
Active
BS 1377: Part 2: 1990
DIN EN 12457
No DETSC 5012 based on BS EN
staining based on HSG 248.
(HSG 248) – 2021
+ 1 more
Normec Hybeta
Active
DIN EN ISO 11737-2
DIN EN ISO 11607-2
DIN EN 868-5
DIN 58341
DIN EN ISO 15883-3
+ 3 more
Normec VRO
Active
#EN ISO 5164:14
# EN 116-97
NEN 4400-1
# ISO 13736
#ISO 6618
+ 3 more
Normec Valitech
Active
Tensile testing of metallic materials (I
positiver Überdruck -0,01 bar
Absolutdruck p
abs
Taupunkttemperatur
+ 3 more
Norsonic-Tippkemper
Active
Akustik
Übertragungsmaß von
Messmikrofonen
Messmikrofonen mit
Dämpfung eines
+ 3 more
North Star Environmental
Active
(HSG 248) – 2021
NSDOC 47 based on HSG 248
staining based on HSG 248.
(PCM) based on HSG 248
Not One Iota
Active
(HSG 248) – 2021
SOP-12, based on HSG 248
staining based on HSG 248
(PCM) based on HSG 248
Nuclear Restoration Services
Active
AIR KERMA RATE
AMBIENT DOSE
HBs-Antigen (Hepatitis B-Surface
RESPONSE:
PERSONEL DOSE
ISO 11423-1
DIN EN 17394-2
ISO 6703-1
EPA 160.1 1971
ISO 14189
+ 3 more
O.C. Consulting (UK)
Active
(HSG 264, 2012)
Appendix 5 of HSG 227 (2004)
(HSG 248) – 2021
(PCM) based on HSG 248
OCA GLOBAL
Active
UNE-EN 14385
UNE-EN 15259
UNE-EN 13211
BS ISO 9096:2017
UNE 77216
+ 3 more
BS 5867:Part 2:2008
BS EN ISO 6941:2003
BS 5438
DIN EN ISO 6940
BS ISO 15025:2000 (withdrawn)
+ 3 more
ONNEKEN Meß- und Prüftechnik
Active
Druck 0,03 bar
Absolutdruck Pabs
> -0,3 bar
> 3,0 bar
> −0,02 bar
+ 3 more
OPTOLUTION Messtechnik
Active
− Wärmezähler
Durchflusssensoren
als Teilgeräte von
Wärme- und
Kältezählern:
+ 3 more
Ober Berg & Lukowiak
Active
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
IEC 61400-23
ASTM G73 (2012)
IEC 60885-3, 2.4.1
IEC 60502-2
IEC 60840
+ 3 more
DIN EN 1568-2
ASTM D891-2018
DIN EN 1568-3
DIN EN 15684
DIN EN 1568-1
ISO 11819-1
(N 2 O) 0,000008
DIN EN ISO 16911-1
AG2 and IS EN 15259:2007
DIN EN 14790
+ 3 more
One Scientific
Active
ISO 6888-1
ISO 21528-2
BS ISO 4832:2006
ISO 4833-1
ISO 6579-1
+ 3 more
Optical Test & Calibration
Active
DC Resistance
DC CURRENT
DC VOLTAGE
DC RESISTANCE (cont’d)
No matching labs found.