ISO 376

Force Transducer Calibration

ISO 376 specifies the calibration procedure for force-proving instruments used to verify the performance of testing machines. Calibrated force transducers are essential for ensuring that tensile, compression, and fatigue testing machines deliver traceable, accurate force measurements. Labs accredited to ISO 376 support traceability chains in aerospace, automotive, and standards laboratories.

What it measures

  • Reproducibility and repeatability of force transducers
  • Resolution and zero output
  • Interpolation error across the calibration range
  • Temperature sensitivity
🇩🇪 DIN EN ISO 376 🇬🇧 BS EN ISO 376 🇫🇷 NF EN ISO 376 🇮🇹 UNI EN ISO 376 🇪🇸 UNE EN ISO 376 🇳🇱 NEN EN ISO 376 🇩🇪 DIN EN ISO 7500-1 🇬🇧 BS EN ISO 7500-1 🇫🇷 NF EN ISO 7500-1 🇮🇹 UNI EN ISO 7500-1 🇪🇸 UNE EN ISO 7500-1 🇳🇱 NEN EN ISO 7500-1
1,495 Accredited labs
18 Countries

Showing 1–25 of 827 labs

1A CAL

Active
DAkkS D-K-15115-01-00 Kassel, DE
- Gleichspannung Josephson-Josephson Multimeter Quellen > 0,2 V Spannungsnormale + 3 more
View Profile
DAkkS D-K-15158-01-00 Haiger, DE
Sound intensity — scanning method (ISO 9 Härteprüfmaschinen Knoop- und 70 HR15N 42 HR30N + 3 more
View Profile

3D Service

Active
DAkkS D-K-18164-01-01 Partenstein, DE
Münchingen, D CAM 2, Software von Holos, Software von Carl Metrologic, Software von Metrologic Group ≤ 9090 mm + 3 more
View Profile
DAkkS D-K-21981-01-00 Konstanz, DE
8tree Scanner / 0 mm bis 100 mm Laterale Größe von Tiefenmaß/ -unterstand (Härteskalen HV0,01
View Profile
DAkkS D-K-17303-01-01 Dresden, DE
Kraft 0,5 N Zug- und Druckkraft Vibration measuring instruments — requir Sound power — in-situ using reference so 20 kN + 3 more
View Profile
DAkkS D-K-12115-01-00 Minden, DE
Absolutdruck p abs positiver Überdruck Positiver Überdruck p e Überdruck p + 3 more
View Profile

AIP

Active
DAkkS D-K-21076-01-01 Haldenwang, DE
Railway brake — anti-slide device (UIC 5 Railway brake — magnetic track brakes (U Railway brakes — conditions for homologa Messgeräte im Kraftfahrwesen − Abgasmessgeräte für Fremdzündungsmotor + 3 more
View Profile
DAkkS D-K-18095-01-00 Karlsfeld, DE
/ Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V + 3 more
View Profile

AL-PRO

Active
DAkkS D-PL-11316-01-00 Großheide, DE
IEC 61400-12-1 * IEC 61400-12-5 * IEC 61400-50 * IEC 61400-50-1 * IEC 61400-50-2 * + 1 more
View Profile

AQRAT

Active
DAkkS D-K-15060-01-00 Dettingen unter Teck, DE
Messschieber für 0 mm Außen-, Innen- und > 500 mm > 1000 mm Tiefenmessschieber * 0 mm Sondermessschieber 0 mm + 3 more
View Profile

ASC

Active
DAkkS D-K-18110-01-00 Pfaffenhofen a.d. Ilm, DE
Beschleunigung 0,5 m/s² bis Beschleunigungsaufnehmer 10 m/s² stoßförmig Schwingungsaufnehmer 300 m/s²
View Profile
DAkkS D-K-19792-01-01 Alsdorf, DE
Gleichstromleistung / Messgeräte Wirkleistung Leistungsfaktor - Gleichspannung + 3 more
View Profile
DAkkS D-K-21152-02-01 Neuss, DE
Druck * –1000 hPa Absolutdruck p abs 150 hPa > 700 hPa > 1300 hPa bis Durchfluss von Gasen 1 L/min + 3 more
View Profile
DAkkS D-K-19342-01-02 Holzkirchen, DE
Taupunkttemperatur Railway braking — urban guided transport Temperaturtransmitter Widerstandssensor *) –30 °C + 3 more
View Profile
DAkkS D-K-18731-01-01 Manching, DE
- Gleichspannung / Messgeräte 1 µV Quellen > 1 V + 3 more
View Profile
DAkkS D-K-19562-01-01 Kaufbeuren, DE
Durchmesser 1 mm 510 mm Rundheitsabweichung 1 mm Parallelitätsabweichung Rundheitsabweichung + 3 more
View Profile
DAkkS D-ML-19804-01-00 Hamburg, DE
Cyclosporin A Everolimus FK 506 (Tacrolimus) Sirolimus 6-Methylmercaptopurin + 3 more
View Profile
DAkkS D-ML-13314-03-00 Lübeck, DE
Fra(X)-Syndrom, FXTAS (FMR1) Friedreich Ataxie (FXN) DRPLA (ATN1) Huntington Krankheit (HTT) Huntington-like (TBP, JPH3) + 3 more
View Profile
DAkkS D-ML-13314-04-00 Kiel, DE
Aldosteron 11-Desoxycorticosteron 11-Desoxycortisol 17-Hydroxypregnenolon 17-Hydroxyprogesteron + 3 more
View Profile
DAkkS D-PL-20258-01-01 Heilbronn, DE
IEC 60512-1-1 IEC 60512-1-2 IEC 60512-2-1 IEC 60512-2-2 IEC 60512-2-5 + 3 more
View Profile
DAkkS D-PL-11092-04-01 Wuppertal, DE
IEC 62752 IEC 61851-1: 2010 IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-6 + 3 more
View Profile
DAkkS D-PL-11092-01-00 Nürnberg, DE
IEC 60352-2 IEC 60352-5 IEC 60512-6-3 DIN EN 60512-7-1 IEC 60512-15-1 + 3 more
View Profile
DAkkS D-K-17702-01-00 Garching, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu nichtselbsttätige + 2 more
View Profile
DAkkS D-K-15079-01-00 Alsdorf, DE
Absolutdruck p abs 0,015 bar > 2 bar > 42 bar Absolutdruck Pabs 1 bar; 2 bar + 3 more
View Profile
DAkkS D-PL-22860-01-01 Reutlingen, DE
DIN 55635 VDE 0468-2-14 VDE 0468-2-1 VDE 0468-2-5 DIN EN 60068-2-30 + 3 more
View Profile

No matching labs found.

Industries

Calibration Laboratories Aerospace Automotive Research Institutes

Related Standards

  • ISO 376 Metallic materials -- Calibration of force-proving instruments
  • EURAMET cg-4 Uncertainty of Force Measurements
  • ISO 7500-1 Static uniaxial testing machines -- Verification and calibration

Other Test Methods

0 labs selected
Compare