ISO 376
Force Transducer Calibration
ISO 376 specifies the calibration procedure for force-proving instruments used to verify the performance of testing machines. Calibrated force transducers are essential for ensuring that tensile, compression, and fatigue testing machines deliver traceable, accurate force measurements. Labs accredited to ISO 376 support traceability chains in aerospace, automotive, and standards laboratories.
What it measures
- Reproducibility and repeatability of force transducers
- Resolution and zero output
- Interpolation error across the calibration range
- Temperature sensitivity
🇩🇪
DIN EN ISO 376
🇬🇧
BS EN ISO 376
🇫🇷
NF EN ISO 376
🇮🇹
UNI EN ISO 376
🇪🇸
UNE EN ISO 376
🇳🇱
NEN EN ISO 376
🇩🇪
DIN EN ISO 7500-1
🇬🇧
BS EN ISO 7500-1
🇫🇷
NF EN ISO 7500-1
🇮🇹
UNI EN ISO 7500-1
🇪🇸
UNE EN ISO 7500-1
🇳🇱
NEN EN ISO 7500-1
1,713
Accredited labs
19
Countries
Showing 251–275 of 898 labs
Hygiene Nord
Active
DIN EN ISO 10993-5
DIN EN ISO 10993-1
DIN EN ISO 11737-2
DIN EN 1040
DIN EN IEC 60601-2-75
+ 3 more
Hygiene-Institut AYSID
Active
DIN 1946-4
DIN EN 13098
DIN EN ISO 17141
ISO 14644-3
DIN 12980
+ 1 more
Innen- und Tiefenmaße
Konventioneller
Wägewert/
Massenormale
Festkörpervolumen
+ 3 more
Höntzsch
Active
Strömungsgeschwindigkeit
von Gasen 0,1 m/s
Volumendurchfluss
≥ 0,4 m³/h bis
Railway pantographs — requirements for m
+ 3 more
IAMT Engineering
Active
Railway brake — magnetic track brakes (U
− Gleichspannung
− Spannungsverhältnis
− Frequenz und Drehzahl
nur Vor-Ort-Kalibrierung
+ 3 more
Messgeräte 0,01 V
Messgeräte 0,33 V
3,3 V
330 V
Quellen 0,01 V
+ 3 more
Kraft 10 kN
Sound power — survey method (ISO 3746)
Radaufstandskraft- 10 kN
Prüfkraftmesseinrichtung
Länge 10 mm
HbA1c
Vitamin A
Vitamin B1
Vitamin B2
Vitamin B6
+ 3 more
Thrombozytenaggregometrie
Drogen- und
Medikamentenscreening
Freie Fettsäuren
Linolensäure, Eicosapentaensäure
+ 3 more
DIN EN ISO 5667-1 (A 4)
DIN 38402-A 11
DIN 38402-A 12
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
+ 3 more
ASTM F1978
ASTM G195
DIN EN ISO 4287
DIN EN ISO 4288
DIN EN ISO 5470-1
+ 3 more
Temperaturanzeigegeräte –100 °C
- Thermopaare, Thermoelemente
Typ J, K und N
für Widerstands- –100 °C
- Direktanzeigende Thermometer
+ 3 more
Fettsäureprofil der
Erythrozytenmembran
Kurzkettige Fettsäuren
MMA (Methylmethacrylat)
Gesamtporphyrine
+ 3 more
Hämoglobin A1c (HbA1c)
Differenzialblutbild
Erythrozyten
Erythroblasten (NRBC)
Hämatokrit
+ 3 more
HbA1c
Eosinophile, Basophile, MCV, MCH)
Retikulozyten
Urinsediment
Elektrolyte (Kalium, Natrium, Chlorid)
+ 3 more
IEC 61000-3-2: 2014
VDE 0838-2
IEC 61000-3-3
VDE 0838-3
IEC 61000-4-2: 2008
+ 3 more
Plasma, Serum, Plasma 0,5 mmol/L
Plasma, Serum, Plasma 50 mmol/L
Plasma, Serum, Plasma
Material
Urin
+ 3 more
IEC 62271-1: 2017-07
DIN EN 62271-1
VDE 0671-1
IEC 62271-100: 2021
VDE 0671-100
+ 3 more
DIN EN 1230-1
EN 1230-2
DIN 10955
DIN ISO 8784-1
DIN 54378
+ 3 more
ISO 6508-1
Charpy impact test (ISO 148-1)
Tensile testing of metallic materials (I
BS EN ISO 9015-2
BS EN ISO 9016:2022
+ 3 more
- Gleichstromwiderstand
/ Messgeräte
Quellen
>100 Ω
> 10 kΩ
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
Ingenieurbüro g o e b e l
Active
DIN 56912
DIN EN 12198-1
DIN EN 12198-2
DIN EN 12198-3
DIN EN 60825-1
+ 3 more
Taupunkttemperatur
Railway braking — urban guided transport
Railway vehicle body structural requirem
Railway bogies — wheelsets and bogies st
Elektrische
+ 3 more
No matching labs found.