ISO 376

Force Transducer Calibration

ISO 376 specifies the calibration procedure for force-proving instruments used to verify the performance of testing machines. Calibrated force transducers are essential for ensuring that tensile, compression, and fatigue testing machines deliver traceable, accurate force measurements. Labs accredited to ISO 376 support traceability chains in aerospace, automotive, and standards laboratories.

What it measures

  • Reproducibility and repeatability of force transducers
  • Resolution and zero output
  • Interpolation error across the calibration range
  • Temperature sensitivity
🇩🇪 DIN EN ISO 376 🇬🇧 BS EN ISO 376 🇫🇷 NF EN ISO 376 🇮🇹 UNI EN ISO 376 🇪🇸 UNE EN ISO 376 🇳🇱 NEN EN ISO 376 🇩🇪 DIN EN ISO 7500-1 🇬🇧 BS EN ISO 7500-1 🇫🇷 NF EN ISO 7500-1 🇮🇹 UNI EN ISO 7500-1 🇪🇸 UNE EN ISO 7500-1 🇳🇱 NEN EN ISO 7500-1
1,713 Accredited labs
19 Countries

Showing 351–375 of 1,713 labs

ENAC LC10.227 Santa Cruz de Tenerife, ES
EURAMET cg-17 EURAMET cg-11 CEM EL-010 CEM EL-001 CEM EL-025 + 2 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile

DJB Labcare

Active
UKAS 8807 Newport Pagnell, GB
TEMPERATURE ROTATIONAL SPEED TIME INTERVAL CARBON DIOXIDE
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
UKAS 0143 Letchworth Garden City, GB
LENGTH Blade type Straight edges Surface plates External micrometer + 3 more
View Profile
DAkkS D-PL-11035-01-02 Essen, DE
ID136 > 140 DIN EN 143 DIN EN ISO 21149 DIN EN 13274-1 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
COFRAC 1-10039 Marseille, FR
NF X 43-050 NF X43-050 (parties ISO 22262-2 NF ISO 22262-1 et/ou ISO 22262-1
View Profile
COFRAC 1-10029 Colomiers, FR
NF X 43-050 NF X43-050 (parties
View Profile
COFRAC 1-10041 Villebon-Sur-Yvette, FR
NF X 46-032 NF X 43-050 NF X43-050 (parties
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-00 Hagen, DE
AB0-Blutgruppen-Merkmale Isoagglutinine (Serumeigenschaften) Rhesusmerkmale K-Merkmale + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
UKAS 7783 Belfast, GB
DIN EN 12469 EN 14175-3-2004
View Profile
UKAS 4303 Ammanford, GB
1) MS08P based on BS EN ISO MS02P based on BS EN ISO MS03P based on BS EN ISO MS06P based on BS EN ISO MF07P based on BS EN ISO + 3 more
View Profile

No matching labs found.

Industries

Calibration Laboratories Aerospace Automotive Research Institutes

Related Standards

  • ISO 376 Metallic materials -- Calibration of force-proving instruments
  • EURAMET cg-4 Uncertainty of Force Measurements
  • ISO 7500-1 Static uniaxial testing machines -- Verification and calibration

Other Test Methods

0 labs selected
Compare