DIN 45642
Traffic Noise Immission Measurement
DIN 45642 specifies standardized methods for measuring noise immissions from road and rail traffic at receiver locations. This test quantifies sound pressure levels and frequency characteristics of traffic noise in the environment, typically at building facades or sensitive areas. Municipalities, environmental authorities, and transportation agencies require this test to assess compliance with noise limit values and evaluate environmental impact. Accreditation ensures measurements are reproducible, comparable, and defensible in regulatory and legal proceedings. Proper measurement following this standard is critical for noise action planning and protection of public health.
What it measures
- Sound pressure level (Leq, LA) from traffic sources
- Maximum sound pressure levels (Lmax, LAmax)
- Frequency spectrum analysis
- Temporal noise characteristics
- Compliance with national noise limit values
🇩🇪
DIN EN ISO 3744
🇬🇧
BS EN ISO 3744
🇫🇷
NF EN ISO 3744
🇮🇹
UNI EN ISO 3744
🇪🇸
UNE EN ISO 3744
🇳🇱
NEN EN ISO 3744
🇩🇪
DIN EN ISO 1996-1
🇬🇧
BS EN ISO 1996-1
🇫🇷
NF EN ISO 1996-1
🇮🇹
UNI EN ISO 1996-1
🇪🇸
UNE EN ISO 1996-1
🇳🇱
NEN EN ISO 1996-1
1,868
Accredited labs
20
Countries
Showing 201–225 of 906 labs
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAVICAL
Active
Innen- und Tiefenmaße
Konventioneller
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
+ 1 more
GTM Testing and Metrology
Active
Vickers hardness test (ISO 6507)
Kraft
Kraftaufnehmer und
Sound power — survey method (ISO 3746)
0,2 MN
+ 3 more
GTÜ Prüfmittelservice
Active
Abgasmessgeräte für
motoren
Transmissionsfilter
Trübungsgrad N
Transmission T
+ 3 more
DIN 30655-1
DIN 30655-2
DIN 3590-1
DIN 3590-2
DIN 30652-2
+ 3 more
Anti-Müller-Hormon
Androstendion
CA 125
Cortisol
DHEA-S
+ 3 more
Azoospermie (AZF-Mikrodeletionen)
Fragiles X-Syndrom (FMR1)
Chorea Huntington (HTT)
Spinocerebelläre Ataxie Typ1
(ATXN1); Typ 2 (ATXN2); Typ 3
+ 3 more
HLA Klasse I Antikörper
lymphozytäre Antikörper
donorspezifische komplementabhängige
Gerinnungszentrum Rhein-Ruhr
Active
Thrombozytenaggregation
Epinephrin-Ristocetin) nach
Verschlusszeitbestimmung
Kollagen / ADP, PFA-Kollagen
Epinephrin, PFA-P2Y)
+ 3 more
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Active
ISO 1920-4
DIN EN 480-11
DIN EN 12350-1
DIN EN 12350-3
DIN EN 12350-6
+ 3 more
Aktivator ADP / Epinephrin
Thrombozytenfunktionstest
Basophile Leukozyten, absolut
Basophile Leukozyten
Eosinophile Leukozyten
+ 3 more
ISO 354
BS EN ISO 717-2:2020
ISO 7171
UNE-EN ISO 3382-2
BS EN ISO 10140-3:2021
+ 3 more
Gigahertz Optik
Active
spektrale
Mikrofonempfindlichkeit
Photodioden
1 µA/W
Bestrahlungsstärke
+ 3 more
Grohe
Active
DIN EN 22248
DIN ISO 1817
IEC 60512-11-11
IEC 60512-11-12
DIN EN ISO 3822-1
+ 3 more
ASTM D3835-16
ASTM D6204-19a
ASTM D6601-19
ISO 11443
ASTM D1238-13
+ 3 more
ISO 3105
ASTM D 7042
ISO 2909
ASTM D 5293
ISO 3104
+ 3 more
HAZET-WERK Hermann Zerver
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Drehmoment 2 N·m
Handbetätigte
20 N·m
+ 3 more
Verschlusszeit (ADP, Epinephrin, P2Y12)
HCG, ß-HCG
PF4/Heparin-Komplexe
induzierte Thrombozytopenie, Test)
Differenzialblutbild (maschinell)
+ 3 more
HCG, ß-HCG
Ampicillin
Cefipim
Hämoglobin A1c (HbA1c)
Linecolid
+ 3 more
ADP-Antagonisten
TRAP-6-Aktivierung
ASS-Inhibition
Thrombozyten-Funktionsanalyse
β-HCG
+ 3 more
HENSOLDT Sensors
Active
- Gleichspannung
Spannungsmessgeräte
> 20 V
> 200 V
Spannungsquellen
+ 3 more
Natriumchlorid
Glucose
Kalium
Natrium
Albumin
+ 3 more
No matching labs found.