EN 13749:2020
Railway Bogie Structural Requirements and Design
This standard specifies structural design and performance requirements for bogie frames and running gear assemblies used on railway vehicles. It covers load analysis, stress calculations, fatigue assessment, and structural integrity of the frame components that support and guide the wheelsets. Accreditation for bogie structural testing ensures that bogies meet load-carrying and dynamic performance standards essential for safe, reliable railway operation at design speeds and over extended service periods.
What it measures
- Bending stress and shear force distribution in frame members
- Fatigue strength under cyclic loading conditions
- Lateral and vertical load-carrying capacity
- Connection weld quality and structural soundness
- Deformation under operational and exceptional loads
🇩🇪
DIN EN 12663-1
🇬🇧
BS EN 12663-1
🇫🇷
NF EN 12663-1
🇮🇹
UNI EN 12663-1
🇪🇸
UNE EN 12663-1
🇳🇱
NEN EN 12663-1
🇩🇪
DIN EN 13104
🇬🇧
BS EN 13104
🇫🇷
NF EN 13104
🇮🇹
UNI EN 13104
🇪🇸
UNE EN 13104
🇳🇱
NEN EN 13104
1,399
Accredited labs
17
Countries
Showing 76–100 of 800 labs
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
Coesfeld
Active
Kraft (WPM)
Belastungseinrichtungen von
Werkstoffprüfmaschinen
Länge (WPM) 0,5 mm
messeinrichtungen von
+ 3 more
Messgeräte 0,001 V
> 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
auch Vor-Ort Kalibrierung
bahntypischer
–0,26 mm
+ 3 more
DIN EN ISO 9012
ISO 22967
ISO 22968
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP
DIN EN 30-1-1
+ 3 more
DECOM-UGK Werkzeugtechnik
Active
(ein- und mehrgängige
zylindrische Außen- und
metrischem Profil)
Außengewinde Nenndurchmesser
Flankendurchmesser 1 mm
+ 3 more
DEKRA Automobil
Active
DIN EN ISO 5667-3
DIN EN ISO 15587-2
DIN EN 12457-4
DIN EN 13346
DIN EN 13657
+ 3 more
IEC 60335-1: 2010
IEC 60335-2-2
IEC 60335-2-3
DIN EN 60335-2-3: 2002
IEC 60335-2-4
+ 3 more
DEPRAG SCHULZ GMBH u.
Active
Drehmoment 0,01 N·m
Railway — traction effort and braking fo
0,1 N·m
- Gleichspannung
Messgeräte > 330 mV
> 3,3 V
> 33 V
> 330 V
+ 3 more
DIANOVIS
Active
Kleines Blutbild (maschinell)
Differentialblutbild (maschinell)
Thrombozyten
Retikulozyten
Natriumchlorid
+ 3 more
Gleichspannung 10 mV
Quellen > 100 mV
> 1 V
> 10 V
> 100 V
+ 3 more
ASTM C 1166
IEC 60512-16-7
ID168
IEC 60512-16-9
AK gegen Sc1-70
+ 3 more
DKMS Life Science Lab g
Active
Antikörper FILA-Klasse I
Lymphozytäre Kreuzprobe
E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1,
KIR
MICA, MICB, CCR5832
+ 3 more
HLA-Typsierung (HLA-B*27)
Azoospermiefaktor
(AZFa/AZFb/AZFc)
Chorea Huntington (HTT)
OMIM# 143100
+ 3 more
DNV Energy Systems Germany
Active
− Stromstärkeverhältnis
- Gleichspannung
/ Messgeräte
- Wechselspannung
Gleichstromstärke > 100 µA
+ 3 more
Faktor-V-Mangel (F5 inklusive
Thrombozyten, PAC-1 Bindung
CASQ2, KCNJ2, CALM2, CALM3, TECRL )
dbSNP r6027 )
Kardiomyopathie (PKP2, DSG2, SCN5A )
+ 3 more
aller Untersuchungsverfahren im flexible
Webpräsenz des Medizinischen Laboratoriu
(VWF:CB)
vWF-Multimere
Erythrozyten
+ 3 more
CD34+ Stammzellen
Erythrozyten
Hämoglobin
Leukozyten
Bakterien- und Hefezellen
+ 3 more
Akkreditierungsbereich. Die Liste ist
Erythrozyten
Leukozyten
Hämatokrit
Thrombozyten
+ 3 more
AB0-System
Isoagglutinine
(Serumeigenschaften)
Rh-Merkmal D
Rh-Untergruppen
+ 3 more
(Serumeigenschaften)
Dithiothreithol-Behandlung
Absorption oder Elution
HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree
Liquorzelldifferenzierung
+ 3 more
DSA Daten- und Systemtechnik
Active
am Standort DSA Daten- und Systemtechnik
Schreibendes
Bremsmessgerät
(HU-Adapter)
Beschleunigung
+ 1 more
DSM Messtechnik
Active
- Gleichspannung
> 0,01 V
- Gleichstromstärke
0,1 mV/V
> 2 mV/V
+ 3 more
No matching labs found.