EN 13749:2020
Railway Bogie Structural Requirements and Design
This standard specifies structural design and performance requirements for bogie frames and running gear assemblies used on railway vehicles. It covers load analysis, stress calculations, fatigue assessment, and structural integrity of the frame components that support and guide the wheelsets. Accreditation for bogie structural testing ensures that bogies meet load-carrying and dynamic performance standards essential for safe, reliable railway operation at design speeds and over extended service periods.
What it measures
- Bending stress and shear force distribution in frame members
- Fatigue strength under cyclic loading conditions
- Lateral and vertical load-carrying capacity
- Connection weld quality and structural soundness
- Deformation under operational and exceptional loads
🇩🇪
DIN EN 12663-1
🇬🇧
BS EN 12663-1
🇫🇷
NF EN 12663-1
🇮🇹
UNI EN 12663-1
🇪🇸
UNE EN 12663-1
🇳🇱
NEN EN 12663-1
🇩🇪
DIN EN 13104
🇬🇧
BS EN 13104
🇫🇷
NF EN 13104
🇮🇹
UNI EN 13104
🇪🇸
UNE EN 13104
🇳🇱
NEN EN 13104
1,399
Accredited labs
17
Countries
Showing 276–300 of 1,399 labs
DIPE ELECTRÓNICA
Active
0 mV U < 330 mV 330 mV U < 3,3 V 3,3
0 mV U < 120 mV 120 mV U < 1,2 V 1,2
0 A I 330 A 330 A < I 3,3 mA 3,
20 A I 1025 A
20 A I 1025 A F = 50 Hz
+ 3 more
SM 5210 D
UNE-EN ISO 27888
SM 5220 D
SM 2130 B
UNE-EN ISO 11885
+ 3 more
DKMS Life Science Lab g
Active
Antikörper FILA-Klasse I
Lymphozytäre Kreuzprobe
E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1,
KIR
MICA, MICB, CCR5832
+ 3 more
HLA-Typsierung (HLA-B*27)
Azoospermiefaktor
(AZFa/AZFb/AZFc)
Chorea Huntington (HTT)
OMIM# 143100
+ 3 more
DNKA
Active
staining based on HSG 248.
(PCM) based on HSG 248
(HSG 248) – 2021
QSOP 03 based on HSG 248
QSOP 01 based on HSG 248
DNV Energy Systems Germany
Active
− Stromstärkeverhältnis
- Gleichspannung
/ Messgeräte
- Wechselspannung
Gleichstromstärke > 100 µA
+ 3 more
Faktor-V-Mangel (F5 inklusive
Thrombozyten, PAC-1 Bindung
CASQ2, KCNJ2, CALM2, CALM3, TECRL )
dbSNP r6027 )
Kardiomyopathie (PKP2, DSG2, SCN5A )
+ 3 more
aller Untersuchungsverfahren im flexible
Webpräsenz des Medizinischen Laboratoriu
(VWF:CB)
vWF-Multimere
Erythrozyten
+ 3 more
CD34+ Stammzellen
Erythrozyten
Hämoglobin
Leukozyten
Bakterien- und Hefezellen
+ 3 more
Akkreditierungsbereich. Die Liste ist
Erythrozyten
Leukozyten
Hämatokrit
Thrombozyten
+ 3 more
AB0-System
Isoagglutinine
(Serumeigenschaften)
Rh-Merkmal D
Rh-Untergruppen
+ 3 more
(Serumeigenschaften)
Dithiothreithol-Behandlung
Absorption oder Elution
HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree
Liquorzelldifferenzierung
+ 3 more
DSA Daten- und Systemtechnik
Active
am Standort DSA Daten- und Systemtechnik
Schreibendes
Bremsmessgerät
(HU-Adapter)
Beschleunigung
+ 1 more
DSM Messtechnik
Active
- Gleichspannung
> 0,01 V
- Gleichstromstärke
0,1 mV/V
> 2 mV/V
+ 3 more
50 ∙ 10-9 mol/mol ≤ C ≤ 237 · 10-9 mol/m
30∙ 10-9 mol/mol ≤ C ≤ 500 ∙ 10-9 mol/mo
50 ∙ 10-9 mol/mol ≤ C ≤ 1000 · 10-9 mol/
50 ∙ 10-9 mol/mol ≤ C ≤ 237∙ 10-9 mol/mo
0,5 ∙ 10-9 mol/mol ≤ C ≤ 15 ∙ 10-9 mol/m
+ 1 more
DTNW Öffentliche Prüfstelle
Active
DIN EN ISO 11357-2
DIN EN ISO 11357-3
DIN EN ISO 3071
DIN 54278-1
ISO 11890-2
+ 3 more
ASTM D 3227
DIN 3500
EN 14350-2
DIN EN 12350-9
DIN 53512
+ 3 more
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP
DIN EN 30-1-1
DIN EN 30-1-2
DIN 13013
DIN 13014
+ 3 more
Decus Research
Active
1) MS08P based on BS EN ISO
MS02P based on BS EN ISO
MS03P based on BS EN ISO
MS06P based on BS EN ISO
MF07P based on BS EN ISO
+ 3 more
Metrologic Group GmbH, nalen von:
Wernau, D
Neuss, D ≤ 1515 mm
Wetzlar, D
S.p.A., Turin, I
+ 3 more
ETSI EN 319 412
ETSI EN 319 401
ETSI EN 319 411-2
ETSI EN 319 411-1
DIN EN 60950-1
EN IEC 62368-1
DIN EN 60204-1
DIN EN 60825-1
DIN EN 61010-1
+ 3 more
IEC 60335-1: 2010
IEC 60335-2-29
DIN EN 60335-2-29
IEC 60335-2-65
DIN EN 60335-2-65
+ 3 more
No matching labs found.