EN 13749:2020
Railway Bogie Structural Requirements and Design
This standard specifies structural design and performance requirements for bogie frames and running gear assemblies used on railway vehicles. It covers load analysis, stress calculations, fatigue assessment, and structural integrity of the frame components that support and guide the wheelsets. Accreditation for bogie structural testing ensures that bogies meet load-carrying and dynamic performance standards essential for safe, reliable railway operation at design speeds and over extended service periods.
What it measures
- Bending stress and shear force distribution in frame members
- Fatigue strength under cyclic loading conditions
- Lateral and vertical load-carrying capacity
- Connection weld quality and structural soundness
- Deformation under operational and exceptional loads
🇩🇪
DIN EN 12663-1
🇬🇧
BS EN 12663-1
🇫🇷
NF EN 12663-1
🇮🇹
UNI EN 12663-1
🇪🇸
UNE EN 12663-1
🇳🇱
NEN EN 12663-1
🇩🇪
DIN EN 13104
🇬🇧
BS EN 13104
🇫🇷
NF EN 13104
🇮🇹
UNI EN 13104
🇪🇸
UNE EN 13104
🇳🇱
NEN EN 13104
1,399
Accredited labs
17
Countries
Showing 576–600 of 1,399 labs
eingängige zylindrische
Einstellnormale
Lehrdorne
Durchmesser 1 mm
Prüfstifte
+ 3 more
KEMA
Active
IEC 60034
IEC 60034-2-1
IEC 60034-18-1
IEC 60034-4-1
IEC 60034-27-1
+ 3 more
basophile, eosinophile, Granulozyten
Differenzialblutbild
Erythrozyten
Erythrozytenverteilungsbreite
(RDW)
+ 3 more
KRIWAN Testzentrum
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
KROMSCHROEDER
Active
Caudal m3/h 0,010 m3/h Q 250 m3/h 0,
Caudal m3/h 0,16 m3/h Q 2500 m3/h 0,
Kalibrierservice Brandl
Active
Gleichspannung 0 mV
Messgeräte > 200 mV
> 2 V bis 20 V
> 20 V bis 200 V
> 200 V bis 1000 V
+ 3 more
Kapraun Prüfdienst
Active
Railway brake — magnetic track brakes (U
− Ebenheit
− Geradheit
− Winkelnormale
auch als Vor-Ort-Kalibrierung
+ 3 more
IEH
Active
DIN EN 60034-15
VDE 0530-15
IEC 60034-15
DIN EN 60044-7
VDE 0414-44-7
+ 3 more
DIN EN 62196-1: 2015
DIN EN 196-2
DIN EN 196-3
DIN EN 196-5
DIN EN 196-6
+ 3 more
Luftkerma/-leistung
Dosis
Dosisleistung
Kern & Sohn
Active
nichtselbsttätige
− Waagen
Festkörpervolumen
Wägewert/
Masse oder
+ 3 more
Kessler QMP
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße *
Einstelldorne * 1 mm
Railway maintenance — track geometry (EN
+ 3 more
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
EN IEC 61010-2
VDE 0411-2-010
+ 3 more
- Gleichspannung
/ Messgeräte
Spannungsquellen
- Gleichstromstärke
- Gleichstromwiderstand
+ 3 more
Kistler Instrumente
Active
Beschleunigung*
Beschleunigungsmessketten
(Bezugsfrequenzen)
(Mittelfrequenzbereich)
Beschleunigungsaufnehmer, 0,1 m/s
+ 3 more
Kistler Remscheid
Active
Vickers hardness test (ISO 6507)
Kalibrier- und Messmöglichkeiten
Drehmoment 0,01 N•m
Railway — traction effort and braking fo
0,1 N-m
+ 3 more
Kiwa Assurance
Active
EN ISO 11925-2
DIN EN ISO 13162
DIN EN 14509
DIN EN ISO 13163
DIN EN 1604
+ 3 more
Kiwa
Active
DIN EN 13079
BS 1212-4:1991 Clause 4, 13, 14
DIN EN 14622
BS 1212-3:1990 Clause 4
DIN EN 14623
+ 3 more
Kiwa
Active
DIN EN 55011: 2018
IEC/CISPR 22
DIN EN 55016-2-1
IEC 61326-2-2: 2012
IEC 61000-6-1
+ 3 more
Kiwa
Active
DIN EN 16510-2-3
DIN EN 16510-2-1
DIN EN 13229
DIN EN 16510-1
DIN EN 13240
+ 3 more
Kiwa Nederland
Active
ISO 2781
ISO 1133-1
ISO 6259-1:2015
ISO 6259-3
ISO 6259-2:1997
+ 3 more
Kiwa Primara
Active
BS 1363
DIN VDE 0620-2
DIN VDE 0620-2-1
ISO 12100: 2010
DIN EN 50124-1
+ 3 more
Taupunkttemperatur
fixpunktzellen
Normal- −196 °C bis −189,3442 °C
thermometer (SPRT)
Widerstandsnormal
+ 3 more
No matching labs found.