UIC 540-1, 540-2
Pneumatic Brake Systems for Railway Rolling Stock
UIC 540 establishes technical requirements and test procedures for pneumatic (air) brake systems on freight and passenger trains throughout the European railway network. This standard covers design, performance, safety, and interoperability of brake components including cylinders, valves, pipes, and control systems. Railway manufacturers, brake suppliers, and infrastructure operators require testing to ensure compliance, validate equipment compatibility across different networks, and demonstrate safety performance. Accredited testing provides independent verification that brake systems meet stringent safety and reliability standards essential for railway operations.
What it measures
- Brake force and braking deceleration (m/s²)
- Pressure response and valve actuation times
- Pipe and connection integrity and leakage rates
- Brake cylinder performance and seal integrity
- System compatibility and inter-car coupling performance
🇩🇪
DIN EN 14512
🇬🇧
BS EN 14512
🇫🇷
NF EN 14512
🇮🇹
UNI EN 14512
🇪🇸
UNE EN 14512
🇳🇱
NEN EN 14512
🇩🇪
DIN EN ISO 4413
🇬🇧
BS EN ISO 4413
🇫🇷
NF EN ISO 4413
🇮🇹
UNI EN ISO 4413
🇪🇸
UNE EN ISO 4413
🇳🇱
NEN EN ISO 4413
1,560
Accredited labs
17
Countries
Showing 76–100 of 849 labs
Carl Zeiss
Active
DIN EN 60601-1
IEC 60601-1
DIN EN 60601-1-1
IEC 60601-1-1
IEC 80601-2-77
+ 3 more
Carl Zeiss IQS Deutschland
Active
Carl Zeiss Industrielle ≤ 3818 mm
Oberkochen, D
1) In den CMC sind die erweiterten Messu
Carl Zeiss Industrielle ≤ 20 m
Auswertesoftware Messvolumen mit
+ 3 more
Parallelendmaße 50 mm
DIN EN ISO 3650:1999
Thermischer Ausdeh- Maximale Dimension
Bandbreite
Höhe: 80 mm
+ 3 more
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
CeGaT
Active
angeborener Chromosomensatz
(Imbalancen im Genom, (Duplikationen/Del
SNRPN-Region 15q11-13 UPD15
(UBE3A)
SMN1; Spinale Muskelatrophie
+ 3 more
Cenata
Active
Pränatales Screening auf
Chromosomenstörungen
(Trisomie 21, Trisomie 18, Trisomie
13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
Whole genome sequencing (WGS:
SNV, CNV/SV)
Thyreoidea stimulierendes
(TSH)
17-α-OH-Progesteron
(17-OH-P)
Immunreaktives Trypsin
+ 3 more
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN 38402-A 30
DIN 19643-1
ISO 5667-11
+ 3 more
Coesfeld
Active
Kraft (WPM)
Belastungseinrichtungen von
Werkstoffprüfmaschinen
Länge (WPM) 0,5 mm
messeinrichtungen von
+ 3 more
Messgeräte 0,001 V
> 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
Conatex Ludwig Colbus
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Taupunkttemperatur
Temperatur −40 °C
Railway braking — urban guided transport
+ 3 more
Coretec - Service
Active
Absolutdruck
Positiver und negativer -3,92 kPa
4,02 kPa
Railway brakes — brake performance (UIC
Lungensimulator
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
auch Vor-Ort Kalibrierung
bahntypischer
–0,26 mm
+ 3 more
DIN EN ISO 9012
ISO 22967
ISO 22968
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP
DIN EN 30-1-1
+ 3 more
DECOM-UGK Werkzeugtechnik
Active
(ein- und mehrgängige
zylindrische Außen- und
metrischem Profil)
Außengewinde Nenndurchmesser
Flankendurchmesser 1 mm
+ 3 more
DEKRA Automobil
Active
DIN EN ISO 5667-3
DIN EN ISO 15587-2
DIN EN 12457-4
DIN EN 13346
DIN EN 13657
+ 3 more
IEC 60335-1: 2010
IEC 60335-2-2
IEC 60335-2-3
DIN EN 60335-2-3: 2002
IEC 60335-2-4
+ 3 more
- Gleichspannung
Messgeräte > 330 mV
> 3,3 V
> 33 V
> 330 V
+ 3 more
DIANOVIS
Active
Kleines Blutbild (maschinell)
Differentialblutbild (maschinell)
Thrombozyten
Retikulozyten
Natriumchlorid
+ 3 more
Gleichspannung 10 mV
Quellen > 100 mV
> 1 V
> 10 V
> 100 V
+ 3 more
ASTM C 1166
IEC 60512-16-7
ID168
IEC 60512-16-9
AK gegen Sc1-70
+ 3 more
No matching labs found.