EN 13452-2:2018
Urban Transit Brake Systems Testing Methods
This standard specifies the test procedures and methodologies for validating brake system performance on urban guided transport vehicles in accordance with EN 13452-1 requirements. It defines laboratory and field test protocols for measuring braking distance, thermal performance, mechanical wear, and system reliability under controlled and operational conditions. Accredited laboratories ensure consistent, repeatable testing results that guarantee brake safety across different manufacturers and operating environments in European transit networks.
What it measures
- Braking distance under various load and speed conditions
- Thermal dissipation and fade characteristics
- Wear rates and friction material durability
- Response time of electrical and mechanical components
- System reliability and failure mode testing
🇩🇪
DIN EN 13452-1
🇬🇧
BS EN 13452-1
🇫🇷
NF EN 13452-1
🇮🇹
UNI EN 13452-1
🇪🇸
UNE EN 13452-1
🇳🇱
NEN EN 13452-1
🇩🇪
DIN EN ISO 6310
🇬🇧
BS EN ISO 6310
🇫🇷
NF EN ISO 6310
🇮🇹
UNI EN ISO 6310
🇪🇸
UNE EN ISO 6310
🇳🇱
NEN EN ISO 6310
1,323
Accredited labs
15
Countries
Showing 101–125 of 773 labs
DIN 31051
DIN EN 1005-1
DIN EN 1993-1-1
DIN EN 1993-1
DIN EN 1993-6
+ 3 more
DIN EN ISO 15106-3
DIN EN ISO 1522
DIN 30720-1: 2016-02
DIN 30720-2: 2009-10
DIN 30722-1: 2021-12
+ 3 more
DIN EN ISO 11357-4
IEC 61037
DIN EN ISO 13850
DIN EN ISO 13855
ISO 14119
+ 3 more
IFA Kalibrierlaboratorium
Active
Eigenrauschen
−60 dB
Frequenzbewertung mit
akustischen Signalen
elektrischen Signalen
+ 3 more
DIN 58620: 2007-02
DIN 58621: 2011-10
DIN 58647-7: 1997-12
ID136
> 140
+ 3 more
IEC 61400-12
IEC 61400-12-1
IEC 61400-12-2
IEC 61400-12-3
IEC 61400-12-5
+ 3 more
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
− Strömungsgeschwindigkeit von Gasen
− Widerstandsthermometer
− Temperatur-Transmitter, Datenlogger
+ 3 more
ADP
ASPI
TRAP
Amiodaron, Desethylamiodaron
Mycophenolsäure
+ 3 more
Diagenom
Active
Chromosomensatz (angeboren)
Chromosomensatz (erworben)
Adrenogenitales Syndrom
Angelman-Syndrom (15q11-Region, UBE3A)
Mikrodeletionen; AZFa-c)
+ 3 more
Diagnos MVZ
Active
HbA1c
Differentialblutbild, maschinell
Retikulozyten, maschinell
Kleines Blutbild
Thrombozyten
+ 3 more
Diehl Metering
Active
Volumen strömender 0,0005 m
− Durchfluss von Flüssigkeiten
0,025 m
Wasserzähler und 0,001 m
Durchflusssensoren
+ 3 more
Absolutdruck p *
Vickers hardness test (ISO 6507)
Flüssigkeitsvolumen *
variablem Volumen
aufnehmern sowie
+ 3 more
Staber & Kollegen
Active
Blutbild groß
Thrombozyten
Urinsediment
Natrium
Kalium
+ 3 more
Aminosäureprofil
Guanidinoacetat
Kreatin
Hämoglobinprofil
Nitisinon (NTBC), Succinylaceton
+ 3 more
Druck *
Negativer und
positiver Überdruck -0,01 bar
Positiver Überdruck p e
> 0,015 bar
+ 3 more
Duravit
Active
*6095991, BAG3 [OMIM *6038831
(-13910T>C) rs4988235
- PiM rs6647, PiZ rs28929474, rs17580
DIN EN 997
DIN EN 13407
+ 3 more
VDE 0468-2-1
VDE 0468-2-2
VDE 0468-2-6
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-13
+ 3 more
optische 0 mm
Werkzeugeinstell- und
/ Messgeräte
verwendete Abkürzungen:
DIN 40633-2
DIN 40633-3
DIN 53482
DIN 72551-100
DIN 72551-6
+ 3 more
ELLAB
Active
Taupunkttemperatur
Widerstandssensor
–100 °C bis
> 140 °C bis
> 240 °C bis
+ 3 more
ELMTEC Ingenieurgesellschaft
Active
- Gleichspannung
Messgeräte > 0,004 V
> 0,33 V
> 33 V
> 330 V
+ 3 more
EMCCons RASEK
Active
- Gleichspannung
> 0,12 V
Vorverstärker > 1,2 V
> 12 V
> 120 V
+ 3 more
Railway brake — anti-slide device (UIC 5
Railway brake — magnetic track brakes (U
Railway brakes — conditions for homologa
Railway brakes — disc brake pads (UIC 54
− Durchfluss von Gasen
+ 3 more
ETAS
Active
- Gleichspannung
Quellen und Messgeräte > 1 mV bis
> 10 mV bis
> 100 mV bis
> 10 V bis
+ 3 more
Eckert & Ziegler Nuclitec
Active
Aktivität
20 Bq
> 20 Bq
Spezifische Aktivität
radioaktiver Lösungen 20 Bq·g
+ 3 more
No matching labs found.