EN 16834
Railway Brake Adhesion Performance Testing
This test method evaluates the adhesion performance of railway braking systems under controlled wet and contaminated rail conditions. It assesses the ability of brake systems to generate sufficient friction force while maintaining stable deceleration and preventing wheel lock-up. The test is fundamental for railway operators, brake manufacturers, and rolling stock producers to ensure safe braking performance across varying environmental conditions. Accredited testing ensures independent verification that brake systems meet critical safety requirements for European rail networks and comply with technical specifications for rolling stock.
What it measures
- Adhesion coefficient under wet conditions
- Adhesion coefficient with contaminated rail surfaces
- Brake force generation and stability
- Wheel slip and lock-up prevention
- Performance reproducibility across test cycles
🇩🇪
DIN EN 13979-1
🇬🇧
BS EN 13979-1
🇫🇷
NF EN 13979-1
🇮🇹
UNI EN 13979-1
🇪🇸
UNE EN 13979-1
🇳🇱
NEN EN 13979-1
🇩🇪
DIN EN 15595
🇬🇧
BS EN 15595
🇫🇷
NF EN 15595
🇮🇹
UNI EN 15595
🇪🇸
UNE EN 15595
🇳🇱
NEN EN 15595
1,323
Accredited labs
15
Countries
Showing 151–175 of 773 labs
Fraunhofer-Institut für Holzforschung, Wilhelm-Klauditz-Institut WKI Qualitätsprüfung und -bewertung
Active
DIN ISO 16000-3
DIN EN ISO 12460-3
DIN EN ISO 12460-4
DIN EN ISO 12460-5
100 HV 120
+ 3 more
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kurzschlussstrom
Solarmodule 16 mA
Gleichstrom- und Nieder- 10 mV
+ 3 more
G + B Kalibriertechnik
Active
Druck *
Absolutdruck Pabs
1 bar; 3 bar
Negativer und
positiver Überdruck
+ 3 more
GHMT
Active
DIN EN 50173-1
DIN EN 50173-2
DIN EN 50173-3
DIN EN 50173-4
DIN EN 50173-5
+ 3 more
DIN 51757
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN 237
+ 3 more
GMA-Werkstoffprüfung
Active
Koordinatenmesstechnik
Lasertracker*
0,5 m
1) In den CMC sind die erweiterten Messu
Bügelmessschrauben* 0 mm
+ 3 more
GMC-I Service
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
GPR Gesundheits- und Pflegezentrum Rüsselsheim gemeinnützige GmbH Institut für Laboratoriumsmedizin
Active
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAVICAL
Active
Innen- und Tiefenmaße
Konventioneller
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
+ 1 more
GTM Testing and Metrology
Active
Vickers hardness test (ISO 6507)
Kraft
Kraftaufnehmer und
Sound power — survey method (ISO 3746)
0,2 MN
+ 3 more
GTÜ Prüfmittelservice
Active
Abgasmessgeräte für
motoren
Transmissionsfilter
Trübungsgrad N
Transmission T
+ 3 more
DIN 30655-1
DIN 30655-2
DIN 3590-1
DIN 3590-2
DIN 30652-2
+ 3 more
Anti-Müller-Hormon
Androstendion
CA 125
Cortisol
DHEA-S
+ 3 more
Azoospermie (AZF-Mikrodeletionen)
Fragiles X-Syndrom (FMR1)
Chorea Huntington (HTT)
Spinocerebelläre Ataxie Typ1
(ATXN1); Typ 2 (ATXN2); Typ 3
+ 3 more
Gerinnungszentrum Rhein-Ruhr
Active
Thrombozytenaggregation
Epinephrin-Ristocetin) nach
Verschlusszeitbestimmung
Kollagen / ADP, PFA-Kollagen
Epinephrin, PFA-P2Y)
+ 3 more
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Active
ISO 1920-4
DIN EN 480-11
DIN EN 12350-1
DIN EN 12350-3
DIN EN 12350-6
+ 3 more
Aktivator ADP / Epinephrin
Thrombozytenfunktionstest
Basophile Leukozyten, absolut
Basophile Leukozyten
Eosinophile Leukozyten
+ 3 more
Gigahertz Optik
Active
spektrale
Mikrofonempfindlichkeit
Photodioden
1 µA/W
Bestrahlungsstärke
+ 3 more
Gossen Metrawatt
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
ASTM D3835-16
ASTM D6204-19a
ASTM D6601-19
ISO 11443
ASTM D1238-13
+ 3 more
HAZET-WERK Hermann Zerver
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Drehmoment 2 N·m
Handbetätigte
20 N·m
+ 3 more
Verschlusszeit (ADP, Epinephrin, P2Y12)
HCG, ß-HCG
PF4/Heparin-Komplexe
induzierte Thrombozytopenie, Test)
Differenzialblutbild (maschinell)
+ 3 more
No matching labs found.