UIC 541-04

Automatic Variable Load Brake Testing

This test defines specifications for automatic variable load braking systems that adjust braking force proportionally to the vehicle's loading condition, optimizing stopping distance and wheel adhesion. The standard covers the design, functionality, and performance requirements of automatic load-sensing brake control equipment fitted to freight and passenger trains. Testing verifies that braking force automatically adjusts across the range from empty to fully loaded conditions, enhancing safety and reducing wheel slide risk. Accreditation for this test is critical for manufacturers of brake control systems and railway operators ensuring consistent, safe braking performance regardless of train loading.

What it measures

  • Load-proportional braking force adjustment mechanisms
  • Response characteristics across loading range
  • Wheel adhesion optimization and anti-lock performance
  • System reliability and fail-safe functionality
  • Pressure modulation and control accuracy
🇩🇪 DIN EN 14198 🇬🇧 BS EN 14198 🇫🇷 NF EN 14198 🇮🇹 UNI EN 14198 🇪🇸 UNE EN 14198 🇳🇱 NEN EN 14198
1,560 Accredited labs
17 Countries

Showing 776–800 of 849 labs

Vectoflow

Active
DAkkS D-K-21643-02-00 Gilching, DE
am Standort Vectoflow Windtunnel A, Frie Strömungsgeschwindigkeit von Gasen 15 m/s bis > 38 m/s
View Profile
DAkkS D-K-22858-01-01 Neustadt b. Coburg, DE
- Gleichspannung - Wechselspannung − Frequenz und Drehzahl Railway brake — magnetic track brakes (U auch Vor-Ort Kalibrierung
View Profile
DAkkS D-ML-13393-01-00 Karlsruhe, DE
Blutbild, kleines (Erythrozyten, Leukozy Erythrozyten Leukozyten Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-K-18737-01-01 Jena, DE
− Permanentes Laboratorium Positionen und Abstände gleichgerichteter Kanten positionen von Strukturen (Hartschichtmasken) + 3 more
View Profile
DAkkS D-K-17723-01-00 Wiesthal, DE
Koordinatenmessgeräte von <7000 mm under-Edge, UK INCA3D, Software von Inspect 3D, Cholet, F + 3 more
View Profile
DAkkS D-K-15105-01-00 Klingenberg, DE
Positiver und −1 bar bis −0,03 bar Positiver und negativer (ein- oder mehrgängige > −0,03 bar bis > 0,15 bar bis + 3 more
View Profile
DAkkS D-K-17410-01-01 Korbußen, DE
− Parallelendmaße − Längenmessmittel − Durchmesser − Formabweichung − Gewinde + 3 more
View Profile
DAkkS D-K-20130-01-00 Meissen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen verwendete Abkürzungen: 1) In den CMC sind die erweiterten Messu + 2 more
View Profile

Waagen-Jöhnk

Active
DAkkS D-K-19520-01-00 Dätgen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) verwendete Abkürzungen:
View Profile
DAkkS D-K-19038-01-00 Rimbach, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) verwendete Abkürzungen:
View Profile
DAkkS D-K-17685-01-00 Hardegsen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen verwendete Abkürzungen:
View Profile
DAkkS D-PL-21231-01-00 Marienheide, DE
DIN EN ISO 5667-1 (A 4) * DIN 38402-A 12 * DIN 38402-A 13 * DIN EN ISO 5667-3 (A 21) * DIN 38402-A 30 * + 3 more
View Profile
DAkkS D-PL-14015-01-02 Erding, DE
DIN EN 2561 DIN EN ISO 14126 DIN EN ISO 14125 DIN EN 2563 DIN 53504 + 3 more
View Profile

Weiss Technik

Active
DAkkS D-K-20681-02-00 Balingen, DE
Vickers hardness test (ISO 6507) Temperatur −80 °C Widerstands- > −40 °C thermometer; > 0 °C direktanzeigende > 100 °C + 3 more
View Profile
DAkkS D-K-15006-01-00 Gießen, DE
Steuerungssoftware Messvolumen mit einer Werth Messtechnik ≤ 2330 mm GmbH, Gießen, D Werth Messtechnik ≤ 600 mm Werth Messtechnik ≤ 150 mm
View Profile
DAkkS D-PL-21876-01-01 Dortmund, DE
DIN IEC 60060-1 VDE 0432- 1 IEC 60270 VDE 0434 DIN EN 61243-1 + 3 more
View Profile
DAkkS D-K-14054-01-00 Hörstel, DE
Kohlenstoffmonoxid *) Kohlenstoffdioxid Propan *) Stickstoffmonoxid Distickstoffmonoxid + 3 more
View Profile
DAkkS D-K-20386-01-00 Meppen, DE
Parallelendmaße aus 0,5 mm DIN EN ISO 3650:1999 Einstelldorne Durchmesser 3 mm Durchmesser 5 mm + 3 more
View Profile
DAkkS D-K-15040-01-00 Wuppertal, DE
Charpy impact test (ISO 148-1) nichtselbsttätigen elektronischen Ersatzlastverfahren (Staffelverfahren) + 1 more
View Profile
DAkkS D-K-21902-01-00 Wilsdruff ST Kesselsdorf, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-K-20615-01-00 Weilheim, DE
Tensile testing of metallic materials (I Vickers hardness test (ISO 6507) Taupunkttemperatur Widerstandssensor * –90 °C Datenlogger mit + 3 more
View Profile
DAkkS D-ML-18420-01-00 Lübeck, DE
HbA1c Basophile Eosinophile Thrombozyten Lymphozyten + 3 more
View Profile
DAkkS D-K-15103-01-01 Königswinter, DE
0,05 V - Gleichstromstärke dreiphasig 60 V; 120 V; 240 V > 240 V einphasig 0,002 V + 3 more
View Profile
DAkkS D-K-22359-01-00 Oberursel, DE
Wechselstromstärke 5 mA 5 mA, 10 mA, 20 mA 40 mA, 80 mA, 150 mA 240 mA, 300 mA, 480 mA 600 mA, 720 mA, 960 mA + 3 more
View Profile
DAkkS D-K-23094-01-01 Eisingen, DE
Außengewinde Nenndurchmesser zylindrische Innengewinde − Längenmessgeräte Längenmessmittel Länge + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Brake control system suppliers Freight train operators Passenger rail services Railway certification and safety authorities

Related Standards

  • UIC 541-01 Railway brakes — Braking power
  • UIC 541-05 Railway brakes — Anti-slide device
  • EN 14198 Railway applications — Wheelsets and bogies — Safety requirements for thermal management

Other Test Methods

0 labs selected
Compare