UIC 541-06

Magnetic Track Brake Systems Testing

This test specifies requirements for magnetic rail brakes (also called eddy current or magnetic track brakes) used as supplementary braking systems on trains, particularly for steep gradient sections and emergency deceleration scenarios. These electromagnetic devices generate braking force without contact friction, reducing mechanical wear and enabling higher service speeds. The standard covers magnetic field generation, electromagnetic compatibility, thermal performance, and safety interlocks to prevent unintended activation. Accreditation for this test is vital for ensuring safe operation in mountainous railway networks and validating performance under extended duty cycles where conventional brake systems would overheat.

What it measures

  • Magnetic braking force output and consistency
  • Electromagnetic field characteristics and shielding
  • Thermal dissipation and cooling performance
  • Activation reliability and control system safety
  • Electromagnetic compatibility with train electronics
🇩🇪 DIN EN 61000 🇬🇧 BS EN 61000 🇫🇷 NF EN 61000 🇮🇹 UNI EN 61000 🇪🇸 UNE EN 61000 🇳🇱 NEN EN 61000
1,560 Accredited labs
17 Countries

Showing 176–200 of 849 labs

DAkkS D-K-15088-01-00 Köln, DE
flexiblen Akkreditierungsbereich. Beschleunigung * 10 m/s Beschleunigungsaufnehmer Beschleunigungsaufnehmer 10 m/s digital (DTI) + 3 more
View Profile
DAkkS D-ML-21105-01-01 Penzberg, DE
(somatische genetische ACVR1B, AKT1, AKT2, AKT3, ALOX12B, AMER1 GATA3, GATA4, GATA6, GID4, GNA11,GNA13, CHEK2, CHIC2, CHN1, CIC, CIITA IRF8, IRS2, ITK, JAK1, JAK2, JAK3, JARID + 3 more
View Profile
DAkkS D-PL-21039-04-04 Erlangen, DE
DIN EN ISO 10304-1 DIN EN ISO 11885 DIN EN ISO 15350 DIN EN ISO 15351 DIN EN ISO 17294-2 + 3 more
View Profile
DAkkS D-K-21039-01-00 Erlangen, DE
- Gleichspannung Messgeräte 0,33 V bis < 3,3 V 330 V Quellen > 0,1 V + 3 more
View Profile
DAkkS D-K-17452-01-00 Schalkau, DE
Kraft (WPM) 30 N Vibration measuring instruments — test m maschinen nach DIN Kraft * 10 N Acoustics — tonality assessment (DIN 456 + 3 more
View Profile
DAkkS D-PL-11140-14-00 Braunschweig, DE
DIN ISO 16000-3 DIN EN ISO 12460-3 DIN EN ISO 12460-4 DIN EN ISO 12460-5 100 HV 120 + 3 more
View Profile
DAkkS D-K-11140-02-00 Freiburg, DE
Tensile testing of metallic materials (I Vickers hardness test (ISO 6507) Kurzschlussstrom Solarmodule 16 mA Gleichstrom- und Nieder- 10 mV + 3 more
View Profile
DAkkS D-K-15109-01-01 Titisee-Neustadt, DE
Druck * Absolutdruck Pabs 1 bar; 3 bar Negativer und positiver Überdruck + 3 more
View Profile
DAkkS D-PL-14170-01-03 Hamburg, DE
DIN EN 12579 DIN 19698-1 DIN 19698-2 DIN 51750-2 DIN ISO 11277 + 3 more
View Profile

GHMT

Active
DAkkS D-PL-17559-01-00 Bexbach, DE
DIN EN 50173-1 DIN EN 50173-2 DIN EN 50173-3 DIN EN 50173-4 DIN EN 50173-5 + 3 more
View Profile
DAkkS D-PL-17563-01-00 Stuhr, DE
DIN EN 12469 BS 5726-1 DIN 1946-4 DIN EN 12599 DIN 12980 + 1 more
View Profile
DAkkS D-PL-11085-01-00 Frankfurt am Main, DE
DIN 51757 DIN EN ISO 12185 DIN EN ISO 3405 DIN EN 13016-1 DIN EN 237 + 3 more
View Profile
DAkkS D-K-11243-01-00 Stade, DE
Koordinatenmesstechnik Lasertracker* 0,5 m 1) In den CMC sind die erweiterten Messu Bügelmessschrauben* 0 mm + 3 more
View Profile

GMC-I Service

Active
DAkkS D-K-20313-01-01 Nürnberg, DE
- Gleichspannung Messgeräte > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-PL-14479-01-00 Würzburg, DE
DIN EN ISO 5667-1 (A 4) DIN 38402-A 11 DIN 38402-A 12 DIN 38402-A 13 DIN EN ISO 5667-6 (A 15) + 3 more
View Profile
DAkkS D-ML-13406-01-00 Rüsselsheim, DE
Erythrozytenzahl Hämatokrit Leucozytendifferenzierung Leucozytenzahl MCV + 3 more
View Profile
DAkkS D-ML-18202-01-00 Rüsselsheim, DE
Erythrozytenzahl Hämatokrit Leucozytendifferenzierung Leucozytenzahl MCV + 3 more
View Profile
DAkkS D-K-18186-01-00 Bitterfeld-Wolfen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) Innen- und Tiefenmaße Wägewert/ + 3 more
View Profile

GRAVICAL

Active
DAkkS D-K-21136-01-00 Damme, DE
Innen- und Tiefenmaße Konventioneller Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) + 1 more
View Profile
DAkkS D-K-15106-01-02 Bickenbach, DE
Vickers hardness test (ISO 6507) Kraft Kraftaufnehmer und Sound power — survey method (ISO 3746) 0,2 MN + 3 more
View Profile
DAkkS D-K-20936-01-01 Stuttgart, DE
Abgasmessgeräte für motoren Transmissionsfilter Trübungsgrad N Transmission T + 3 more
View Profile
DAkkS D-PL-18598-01-02 Essen, DE
DIN 30655-1 DIN 30655-2 DIN 3590-1 DIN 3590-2 DIN 30652-2 + 3 more
View Profile
DAkkS D-ML-17457-01-00 Minden, DE
Anti-Müller-Hormon Androstendion CA 125 Cortisol DHEA-S + 3 more
View Profile
DAkkS D-ML-22602-01-01 Berlin, DE
Azoospermie (AZF-Mikrodeletionen) Fragiles X-Syndrom (FMR1) Chorea Huntington (HTT) Spinocerebelläre Ataxie Typ1 (ATXN1); Typ 2 (ATXN2); Typ 3 + 3 more
View Profile
DAkkS D-ML-13161-04-01 Göttingen, DE
HLA Klasse I Antikörper lymphozytäre Antikörper donorspezifische komplementabhängige
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Magnetic brake system suppliers Mountain railway operators High-speed rail services Railway safety and certification bodies

Related Standards

  • UIC 541-01 Railway brakes — Braking power
  • UIC 541-03 Railway brakes — Disc brake components
  • EN 61000 Electromagnetic compatibility (EMC)

Other Test Methods

0 labs selected
Compare