UIC 541-06

Magnetic Track Brake Systems Testing

This test specifies requirements for magnetic rail brakes (also called eddy current or magnetic track brakes) used as supplementary braking systems on trains, particularly for steep gradient sections and emergency deceleration scenarios. These electromagnetic devices generate braking force without contact friction, reducing mechanical wear and enabling higher service speeds. The standard covers magnetic field generation, electromagnetic compatibility, thermal performance, and safety interlocks to prevent unintended activation. Accreditation for this test is vital for ensuring safe operation in mountainous railway networks and validating performance under extended duty cycles where conventional brake systems would overheat.

What it measures

  • Magnetic braking force output and consistency
  • Electromagnetic field characteristics and shielding
  • Thermal dissipation and cooling performance
  • Activation reliability and control system safety
  • Electromagnetic compatibility with train electronics
🇩🇪 DIN EN 61000 🇬🇧 BS EN 61000 🇫🇷 NF EN 61000 🇮🇹 UNI EN 61000 🇪🇸 UNE EN 61000 🇳🇱 NEN EN 61000
1,323 Accredited labs
15 Countries

Showing 251–275 of 1,323 labs

DAkkS D-PL-17438-01-04 Stuttgart, DE
IEC 60335-1: 2010 IEC 60335-2-2 IEC 60335-2-3 DIN EN 60335-2-3: 2002 IEC 60335-2-4 + 3 more
View Profile
ENAC LE147 Campanillas, ES
IEC 61730-2 IEC 61215-1-2 IEC 61215-2 IEC 61215-1-3 IEC 61215-1-4 + 3 more
View Profile
DAkkS D-K-21738-01-01 Köln, DE
- Gleichspannung Messgeräte > 330 mV > 3,3 V > 33 V > 330 V + 3 more
View Profile
UKAS 0138 Irlam, GB
Gas pressure (absolute) Gas pressure (gauge) Hydraulic pressure (gauge) Hydraulic Pressure (absolute) PRESSURE (cont’d) + 1 more
View Profile

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
ENAC LC10.204 Fuenlabrada, ES
0 mV  U < 330 mV 330 mV  U < 3,3 V 3,3 0 mV  U < 120 mV 120 mV  U < 1,2 V 1,2 0 A  I  330 A 330 A < I  3,3 mA 3, 20 A  I  1025 A 20 A  I  1025 A F = 50 Hz + 3 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
ENAC LC10.254 Sevilla, ES
50 ∙ 10-9 mol/mol ≤ C ≤ 237 · 10-9 mol/m 30∙ 10-9 mol/mol ≤ C ≤ 500 ∙ 10-9 mol/mo 50 ∙ 10-9 mol/mol ≤ C ≤ 1000 · 10-9 mol/ 50 ∙ 10-9 mol/mol ≤ C ≤ 237∙ 10-9 mol/mo 0,5 ∙ 10-9 mol/mol ≤ C ≤ 15 ∙ 10-9 mol/m + 1 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Magnetic brake system suppliers Mountain railway operators High-speed rail services Railway safety and certification bodies

Related Standards

  • UIC 541-01 Railway brakes — Braking power
  • UIC 541-03 Railway brakes — Disc brake components
  • EN 61000 Electromagnetic compatibility (EMC)

Other Test Methods

0 labs selected
Compare