UIC 541-5
Railway Disc Brake Pad Homologation
UIC 541-5 specifies the technical requirements and homologation conditions for disc brake pads used in railway rolling stock. This standard establishes performance criteria including friction coefficient stability, wear resistance, thermal durability, and mechanical properties under dynamic braking loads. Testing ensures brake pads function safely across diverse operational temperatures and moisture conditions encountered in European railway networks. Accreditation for this test is critical for brake pad manufacturers and railway operators to guarantee compatibility and safety across standardized European rail systems.
What it measures
- Friction coefficient stability across temperature ranges
- Brake pad wear rate and material loss
- Thermal durability and fade resistance
- Mechanical strength and adhesion to backing plates
- Moisture absorption and water resistance
🇩🇪
DIN EN 14869-1
🇬🇧
BS EN 14869-1
🇫🇷
NF EN 14869-1
🇮🇹
UNI EN 14869-1
🇪🇸
UNE EN 14869-1
🇳🇱
NEN EN 14869-1
1,323
Accredited labs
15
Countries
Showing 176–200 of 773 labs
HCG, ß-HCG
Ampicillin
Cefipim
Hämoglobin A1c (HbA1c)
Linecolid
+ 3 more
ADP-Antagonisten
TRAP-6-Aktivierung
ASS-Inhibition
Thrombozyten-Funktionsanalyse
β-HCG
+ 3 more
HENSOLDT Sensors
Active
- Gleichspannung
Spannungsmessgeräte
> 20 V
> 200 V
Spannungsquellen
+ 3 more
Natriumchlorid
Glucose
Kalium
Natrium
Albumin
+ 3 more
HFB Engineering
Active
DIN EN ISO 10666
DIN 53438-3
rs738409
DIN EN 1382
DIN EN 1383
+ 3 more
Gleichspannung a)
/ Messgeräte
> 600 kV
Messsysteme, Teiler
> 5 kV
+ 3 more
IEC 61000-6-1
IEC 61000-6-2: 2005
VDE 0839-6-1
VDE 0839-6-2
power port EN 61000-4-29
+ 3 more
HLK Stuttgart
Active
DIN EN 442-2
DIN EN 16430-1
DIN EN 16430-2
DIN EN 16430-3
DIN 4703-3
+ 3 more
HYDAC Systems & Services
Active
Gleichspannung 0 µV
Messgeräte > 20 mV
Messgeräte > 200 mV
> 2 V
> 20 V
+ 3 more
HaBu Hauck Prüftechnik
Active
Härte *) 20 HRA
Härtevergleichsplatten 20 HRB
nach Rockwell Verfahren 20 HRC
40 HRD
60 HRF
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Absolutdruck p
abs
> 41 bar
Negativer und
positiver Überdruck
+ 3 more
Hessische Eichdirektion
Active
Masse * 1 mg
konventioneller 2 mg
Wägewert/ Masse
> 5 mg
10 mg
+ 3 more
Hohenstein Laboratories
Active
DIN 53160
DIN 54034
DIN 54056
DIN EN 20105-A02
DIN EN 20105-N01
+ 3 more
Taupunkttemperatur
thermometer, -80 °C bis
Railway braking — urban guided transport
> -35 °C bis
Temperatur- −35 °C bis
+ 3 more
Horiba Europe
Active
0,6 bar
ver Überdruck p e *
Absolutdruck p abs 100 mbar
> 70 mbar
Gaskonzentration
+ 3 more
Hottinger Brüel & Kjaer
Active
Übertragungsmaß von
Messmikrofonen oder
Freifeld-Leerlauf- 20 Hz
Freifeld -Übertragungsmaß
Vorverstärker, nach IEC
+ 3 more
Humanetics Europe
Active
Kraft 500 N
Absolutdruck p *
Kraftaufnehmer * 0,5 kN
Mehrkomponenten Kraft 0,1 kN
Kraftmessgeräte 0,5 kN
+ 3 more
Hydrotechnik
Active
Negativer und
Positiver Überdruck p e
> 0,015 bar
Überdruck p
(ein- oder mehrgängige
+ 3 more
HygCen Germany
Active
DIN EN ISO 10993-1
DIN EN ISO 10993-5
DIN EN ISO 17405
ISO 10993-23
DIN EN ISO 10993-18
+ 3 more
Hygiene Nord
Active
DIN EN ISO 10993-5
DIN EN ISO 10993-1
DIN EN ISO 11737-2
DIN EN 1040
DIN EN IEC 60601-2-75
+ 3 more
Innen- und Tiefenmaße
Konventioneller
Wägewert/
Massenormale
Festkörpervolumen
+ 3 more
Höntzsch
Active
Strömungsgeschwindigkeit
von Gasen 0,1 m/s
Volumendurchfluss
≥ 0,4 m³/h bis
Railway pantographs — requirements for m
+ 3 more
IAMT Engineering
Active
Railway brake — magnetic track brakes (U
− Gleichspannung
− Spannungsverhältnis
− Frequenz und Drehzahl
nur Vor-Ort-Kalibrierung
+ 3 more
HbA1c
Vitamin A
Vitamin B1
Vitamin B2
Vitamin B6
+ 3 more
No matching labs found.