UIC 546

Railway Electropneumatic Brake Systems

UIC 546 specifies technical requirements, testing procedures, and homologation conditions for electropneumatic braking systems and related devices used in passenger train rolling stock. Electropneumatic brakes provide rapid, coordinated braking across train consists by using electrical signals to control pneumatic brake application, improving safety and precision compared to traditional pneumatic systems. This standard ensures interoperability and safety of electropneumatic brake equipment across European rail networks. Accreditation for UIC 546 testing is essential for equipment manufacturers and railway operators deploying modern passenger train fleets with integrated brake control systems.

What it measures

  • Electrical signal transmission and response time
  • Pneumatic brake modulation and control precision
  • Brake force consistency across train consist
  • System reliability and fail-safe operation
  • Electromagnetic compatibility and durability
🇩🇪 DIN EN 61375-1 🇬🇧 BS EN 61375-1 🇫🇷 NF EN 61375-1 🇮🇹 UNI EN 61375-1 🇪🇸 UNE EN 61375-1 🇳🇱 NEN EN 61375-1 🇩🇪 DIN EN 14531-1 🇬🇧 BS EN 14531-1 🇫🇷 NF EN 14531-1 🇮🇹 UNI EN 14531-1 🇪🇸 UNE EN 14531-1 🇳🇱 NEN EN 14531-1
1,560 Accredited labs
17 Countries

Showing 1,501–1,525 of 1,560 labs

DAkkS D-K-15040-01-00 Wuppertal, DE
Charpy impact test (ISO 148-1) nichtselbsttätigen elektronischen Ersatzlastverfahren (Staffelverfahren) + 1 more
View Profile
DAkkS D-K-21902-01-00 Wilsdruff ST Kesselsdorf, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-K-20615-01-00 Weilheim, DE
Tensile testing of metallic materials (I Vickers hardness test (ISO 6507) Taupunkttemperatur Widerstandssensor * –90 °C Datenlogger mit + 3 more
View Profile
UKAS 2437 Udaipur 313 003, IN
DIN EN 55022: 2011 CISPR 22 (1997/2006/2008) IEC/CISPR 16-2-1 CISPR 32 (2015) + A1 (2019) AS/NZS CISPR 11:2004 + 3 more
View Profile

Z LAB Srl

Active
ACCREDIA 01046 Cerea, IT
DIN EN ISO 11546-1 UNI EN ISO 9295 DIN EN ISO 11957 ISO 354 ISO 3741 + 3 more
View Profile
DAkkS D-ML-18420-01-00 Lübeck, DE
HbA1c Basophile Eosinophile Thrombozyten Lymphozyten + 3 more
View Profile
DAkkS D-K-15103-01-01 Königswinter, DE
0,05 V - Gleichstromstärke dreiphasig 60 V; 120 V; 240 V > 240 V einphasig 0,002 V + 3 more
View Profile
DAkkS D-K-22359-01-00 Oberursel, DE
Wechselstromstärke 5 mA 5 mA, 10 mA, 20 mA 40 mA, 80 mA, 150 mA 240 mA, 300 mA, 480 mA 600 mA, 720 mA, 960 mA + 3 more
View Profile
DAkkS D-K-23094-01-01 Eisingen, DE
Außengewinde Nenndurchmesser zylindrische Innengewinde − Längenmessgeräte Längenmessmittel Länge + 3 more
View Profile
DAkkS D-PL-22057-01-01 Ludwigsburg, DE
DIN EN ISO 4210-1 DIN EN ISO 11243 ISO 5775-1 DIN EN 16054 DIN EN 1371-1 + 3 more
View Profile
DAkkS D-ML-13013-01-00 Chemnitz, DE
Thrombozytenfunktion Ristocetin) Thrombozytenaggregation Arachidonsäure, Epinephrin, Kollagen, Ri 17-alpha-Hydroxy-Progesteron + 3 more
View Profile
DAkkS D-ML-13117-01-00 Regensburg, DE
angeborener Chromosomensatz 22q11.2-Mikrodeletionssyndrom (22q11.2) Kopienzahlveränderungen (Regionen laut MLPA-Kit) + 3 more
View Profile
DAkkS D-K-15186-01-01 Bitterfeld-Wolfen, DE
- Gleichspannung Railway vehicles — specific test require Quellen - Gleichstromstärke / Messgeräte + 3 more
View Profile
DAkkS D-K-15186-01-02 Bitterfeld-Wolfen, DE
Masse oder Konventioneller Wägewert/ Massenormale* Massenormale* > 100 g + 3 more
View Profile
DAkkS D-ML-13153-01-00 Jena, DE
Angelmann-Syndrom (15q11-q13 Region) Prader-Willi-Syndrom (15q11-q13 Ausschluss/ Nachweis mütterlicher Zellen im pränatalen + 3 more
View Profile
DAkkS D-K-18080-01-00 Friedrichshafen, DE
Parallelendmaße 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 0,5 mm Parallelendmaße Parallelendmaße > 100 mm + 3 more
View Profile
DAkkS D-K-19937-01-02 Losheim am See, DE
Railway brake — anti-slide device (UIC 5 Messgeräte im Kraftfahrwesen − Rollenbremsprüfstände − Plattenbremsprüfstände − Scheinwerfer-Einstell-Prüfsystem + 3 more
View Profile

ZwickRoell

Active
DAkkS D-K-18351-01-00 Ulm, DE
Absolutdruck p * Kraftmesseinrichtungen von Werkstoffprüfmaschinen Acoustics — tonality assessment (DIN 456 Auflagekraft von Fallmassen + 3 more
View Profile
DAkkS D-ML-13280-01-00 Hamburg, DE
Thombozyten-Funktionstest 10-OH-Carbazepin 11-Deoxycorticosteron 11-Deoxycortisol 21-Deoxycortisol + 3 more
View Profile
DAkkS D-ML-13432-01-00 Würzburg, DE
Automatisches Blutbild Erythrozytenzahl Hämatokrit Hämoglobin Hb im einzelnen Erythrozyten + 3 more
View Profile
DAkkS D-ML-13131-02-01 Hannover, DE
HbA1c Basophile Eosinophile Basophile Granulozyten Lymphozyten + 3 more
View Profile
DAkkS D-ML-13131-01-01 Göttingen, DE
Homovanillinsäure Vanillin-Mandelsäure 5-Hydroxyindolessigsäure VLCFA Phytansäure + 3 more
View Profile
DAkkS D-ML-20928-01-01 Jena, DE
Albumin Alkalische Phosphatase Alpha-Amylase AT3 Bilirubin, direkt + 3 more
View Profile
DAkkS D-ML-13318-01-00 Halle (Saale), DE
HbA1c CDT Vitamin B1 Vitamin B6 Vitamin A + 3 more
View Profile
DAkkS D-ML-18746-01-01 Fürstenfeldbruck, DE
HbA1c Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Hämoglobin + 3 more
View Profile

No matching labs found.

Industries

Passenger rolling stock manufacturers Electropneumatic brake system suppliers Railway operators and fleet managers Railway vehicle certification and testing Rail infrastructure and safety authorities

Related Standards

  • UIC 544-1 Railway brakes — Braking performance
  • EN 61375-1 Railway applications — Train communication network (TCN) — Part 1: Fundamental principles
  • EN 14531-1 Railway applications — Safety requirements for the design of rolling stock