UIC 644

Railway Coach Bogie Behavior Assessment

This standard specifies the behavior and performance requirements for Y25 bogie type coaching stock bogies, focusing on derailment resistance, curving performance, and stability characteristics. It provides test methods and acceptance criteria for evaluating bogie performance through simulation, calculation, and track testing to ensure safe operation across varying track geometries and speeds. Compliance verification is mandatory for coach manufacturers, bogie suppliers, and infrastructure operators to maintain interoperability and prevent accidents. Accredited testing ensures comprehensive evaluation against standardized criteria, reducing operational risks and supporting evidence-based vehicle certification.

What it measures

  • Derailment coefficient and safety margin against derailment
  • Lateral and vertical wheel loads on curves
  • Curve-climbing behavior and stability
  • Dynamic response to track irregularities and switches
  • Forces on bogie frame and guidance components
🇩🇪 DIN EN 14363 🇬🇧 BS EN 14363 🇫🇷 NF EN 14363 🇮🇹 UNI EN 14363 🇪🇸 UNE EN 14363 🇳🇱 NEN EN 14363
1,399 Accredited labs
17 Countries

Showing 76–100 of 800 labs

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-K-11081-02-01 Chemnitz, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 auch Vor-Ort Kalibrierung bahntypischer –0,26 mm + 3 more
View Profile
DAkkS D-PL-11072-01-01 Freiberg, DE
DIN EN ISO 9012 ISO 22967 ISO 22968 (SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 + 3 more
View Profile
DAkkS D-K-17567-01-01 Lauf a. d. Pegnitz, DE
(ein- und mehrgängige zylindrische Außen- und metrischem Profil) Außengewinde Nenndurchmesser Flankendurchmesser 1 mm + 3 more
View Profile
DAkkS D-PL-11060-03-05 Stuttgart, DE
DIN EN ISO 5667-3 DIN EN ISO 15587-2 DIN EN 12457-4 DIN EN 13346 DIN EN 13657 + 3 more
View Profile
DAkkS D-PL-17438-01-04 Stuttgart, DE
IEC 60335-1: 2010 IEC 60335-2-2 IEC 60335-2-3 DIN EN 60335-2-3: 2002 IEC 60335-2-4 + 3 more
View Profile
DAkkS D-K-18255-01-00 Amberg, DE
Drehmoment 0,01 N·m Railway — traction effort and braking fo 0,1 N·m
View Profile
DAkkS D-K-21738-01-01 Köln, DE
- Gleichspannung Messgeräte > 330 mV > 3,3 V > 33 V > 330 V + 3 more
View Profile

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile

No matching labs found.

Industries

Coach and passenger vehicle manufacturers Bogie and suspension system suppliers Railway operators and depot maintenance Track infrastructure and maintenance organizations Vehicle type approval and certification bodies

Related Standards

  • UIC 518 Railway applications — Tests for the acceptance of running characteristics of railway vehicles
  • EN 14363 Railway applications — Running gear — Testing and validation of running behaviour and safety
  • UIC 505-1 Railway vehicles — gauge limits — Part 1: Rolling stock

Other Test Methods

0 labs selected
Compare