EN 16185-2
Railway Brake Disc Acoustic Emissions Testing
This test method evaluates the acoustic emissions generated by railway brake disc and pad/block interactions under controlled conditions. It measures noise characteristics produced during braking events to assess the potential for noise disturbance in railway operations. The test is critical for railway operators and brake component manufacturers seeking to comply with noise regulations and ensure passenger comfort. Accreditation is essential to provide independent, standardized verification that brake systems meet acoustic performance requirements across European rail networks.
What it measures
- Sound pressure levels during brake pad-disc contact
- Frequency spectrum of brake-induced noise
- Peak noise emissions under defined braking scenarios
- Acoustic performance consistency across brake cycles
- Compliance with European noise limits
🇩🇪
DIN EN 16185-1
🇬🇧
BS EN 16185-1
🇫🇷
NF EN 16185-1
🇮🇹
UNI EN 16185-1
🇪🇸
UNE EN 16185-1
🇳🇱
NEN EN 16185-1
🇩🇪
DIN EN 16834
🇬🇧
BS EN 16834
🇫🇷
NF EN 16834
🇮🇹
UNI EN 16834
🇪🇸
UNE EN 16834
🇳🇱
NEN EN 16834
1,516
Accredited labs
17
Countries
Showing 476–500 of 799 labs
Hämoglobin
Selen
Lithium
Zink
Eisen, Kupfer
+ 3 more
Perschmann Calibration
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
> 100 mm
Sonderquerschnitt (rund
Parallelendmaße * > 100 mm
+ 3 more
Temperaturmessgrößen
Widerstandsnormal
thermometer (IPRT)
Zeiss Industrielle
Temperaturmessgrößen −35 °C
+ 3 more
Polytest Ingenieure
Active
DIN EN ISO 9934-1
DIN ISO 815-1
DIN ISO 815-2
DIN ISO 4593
DIN EN 50178: 1998
+ 3 more
Power Diagnostix Systems
Active
Impulsladung
Anstiegszeit
Impulsdauer
Wechselspannung 1 V
> 1,1 kV
+ 3 more
Differentialblutbild
Erythrozyten
Hämatokrit
Leukozyten
Retikulozyten
+ 3 more
HbA1c
Automatisches Blutbild
Leukozyten
Normoblasten
Retikulozyten
+ 3 more
Calcium
Bilirubin gesamt
Creatinkinase-Muscle-Brain
TPZ nach Quick
Immunglobulin A
+ 3 more
ProfEC Ventus
Active
IEC 61400-12 Ed.1 *
IEC 61400-12-1 Ed.3 *
IEC 61400-12-3 Ed.1 *
IEC 61400-12-4 Ed.1 *
IEC 61400-12-5 Ed.1 *
+ 3 more
Prüf-, Überwachungs- und Zertifizierungsgemeinschaft der Straßenausstatter e.V. - StrAus-Zert
Active
DIN 68877-2
DIN EN ISO 2178
DIN EN 16272-1
DIN EN 12899-1
DIN EN 12899-5
+ 1 more
ISO 15835-2
UNE-EN 10002-1
BS EN ISO 15630-1:2019
UNE-EN 10080
BS EN ISO 15630-3:2019
+ 3 more
QS-Grimm
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Zylindrische Normale 1 mm
Innenzylinder *
> 100 mm
+ 3 more
Qopas
Active
Koordinatenmessgeräte geräte mit einem
Chorus, Help-PJM von
DEA Hexagon Metrology
S.p.A., Turin, I
Associates EMS Products, ≤ 1500 mm
+ 3 more
RIO
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
> 100 mm
> 500 mm
> 550 mm
+ 3 more
RMA Mess- und Regeltechnik
Active
Durchfluss von Gasen
Volumendurchfluss 50 m³/h
Railway brakes — brake performance (UIC
(Hochdruck Erdgas
5 bis 51 bar)
+ 1 more
ROTA YOKOGAWA
Active
Masse m strömender
− Durchfluss von Flüssigkeiten
Durchfluss von
1) In den CMC sind die erweiterten Messu
Massedurchfluss dm / dt
+ 3 more
Robert Koch-Institut
Active
Salmonellen
Salmonella enterica, Shigellen, Yersinie
Shigellen
Salmonella sv. Paratyphi
Neisseria meningitidis, Listeria
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
1) In den CMC sind die erweiterten Messu
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN ISO 20884
DIN EN ISO 20846
+ 3 more
Spinocerebelläre Ataxien
Bindegewebserkrankungen: ACTA2, COL1A1,
HD; Chorea Huntington
(Huntingtin-Gen)
Dentatorubrale-Pallidoluysiane
+ 3 more
Durchfluss von 2 m3/h bis 800 rn3/h
− Durchfluss von Flüssigkeiten
Volumendurchfluss
dV/dt von
strörnenden
+ 3 more
SGS Germany
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
No matching labs found.