ISO 3095:2013 / EN ISO 3095
Railway Pass-By Noise Measurement
ISO 3095 defines the standardized method for measuring and reporting noise emitted by railbound vehicles during pass-by at a fixed observer position. This is the primary standard used to assess compliance with European TSI Noise limits and national environmental regulations for passenger and freight trains. Manufacturers, railway operators, and regulatory authorities depend on this test to demonstrate noise performance, support fleet certification, and document compliance with noise reduction requirements. Accredited laboratories provide the independent, traceable measurements required for regulatory approval and public confidence in noise impact assessments.
What it measures
- Sound pressure level during pass-by (LAmax, dB(A))
- Noise emission per axle or per vehicle
- Frequency spectrum of pass-by noise
- Time-weighted sound exposure level
- Noise contribution by vehicle type and condition
🇩🇪
DIN EN ISO 3381
🇬🇧
BS EN ISO 3381
🇫🇷
NF EN ISO 3381
🇮🇹
UNI EN ISO 3381
🇪🇸
UNE EN ISO 3381
🇳🇱
NEN EN ISO 3381
🇩🇪
DIN EN ISO 14837-1
🇬🇧
BS EN ISO 14837-1
🇫🇷
NF EN ISO 14837-1
🇮🇹
UNI EN ISO 14837-1
🇪🇸
UNE EN ISO 14837-1
🇳🇱
NEN EN ISO 14837-1
1,516
Accredited labs
17
Countries
Showing 726–750 of 799 labs
5-Hydroxyindolessigsäure
Amitriptylin/Nortriptylin
Cyclosporin A
Gesamt-Itraconazol
Metanephrine, Normetanephrine
+ 3 more
IEC 60061-1
IEC 60061-2
IEC 60238
IEC 61184
IEC 60400
+ 3 more
Myopathie, Nemaline (TyP1, 3-10:
ASTM E 23-18
ASTM D 1322
Toxizität UGT1A1-Gen rs3064744, rs414832
DIN EN 1789
+ 3 more
Vectoflow
Active
am Standort Vectoflow Windtunnel A, Frie
Strömungsgeschwindigkeit
von Gasen 15 m/s bis
> 38 m/s
DIN EN ISO 1463
DIN EN ISO 3497
DIN EN 14518
DIN EN ISO 18452
IEC 62642-3
+ 3 more
Blutbild, kleines (Erythrozyten, Leukozy
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Vistec Electron Beam
Active
− Permanentes Laboratorium
Positionen und Abstände
gleichgerichteter Kanten
positionen von Strukturen
(Hartschichtmasken)
+ 3 more
WENZEL Metrology
Active
Koordinatenmessgeräte
von <7000 mm
under-Edge, UK
INCA3D, Software von
Inspect 3D, Cholet, F
+ 3 more
WIKA Alexander Wiegand SE &
Active
Positiver und −1 bar bis −0,03 bar
Positiver und negativer
(ein- oder mehrgängige
> −0,03 bar bis
> 0,15 bar bis
+ 3 more
WIN Messmittel und Service
Active
− Parallelendmaße
− Längenmessmittel
− Durchmesser
− Formabweichung
− Gewinde
+ 3 more
Waagen-Dienst Kirste
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
verwendete Abkürzungen:
1) In den CMC sind die erweiterten Messu
+ 2 more
Waagen-Jöhnk
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkürzungen:
Waagen-Kissling
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkürzungen:
Waagenfachhandel Hilke
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
verwendete Abkürzungen:
Wagner Umweltgeologie
Active
DIN EN ISO 5667-1 (A 4) *
DIN 38402-A 12 *
DIN 38402-A 13 *
DIN EN ISO 5667-3 (A 21) *
DIN 38402-A 30 *
+ 3 more
DIN EN 2561
DIN EN ISO 14126
DIN EN ISO 14125
DIN EN 2563
DIN 53504
+ 3 more
Steuerungssoftware Messvolumen mit einer
Werth Messtechnik ≤ 2330 mm
GmbH, Gießen, D
Werth Messtechnik ≤ 600 mm
Werth Messtechnik ≤ 150 mm
DIN IEC 60060-1
VDE 0432- 1
IEC 60270
VDE 0434
DIN EN 61243-1
+ 3 more
Kohlenstoffmonoxid *)
Kohlenstoffdioxid
Propan *)
Stickstoffmonoxid
Distickstoffmonoxid
+ 3 more
Wocken Industriepartner
Active
Parallelendmaße aus 0,5 mm
DIN EN ISO 3650:1999
Einstelldorne
Durchmesser 3 mm
Durchmesser 5 mm
+ 3 more
Charpy impact test (ISO 148-1)
nichtselbsttätigen
elektronischen
Ersatzlastverfahren
(Staffelverfahren)
+ 1 more
WÄGETECHNIK WEHLE
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
1) In den CMC sind die erweiterten Messu
ZENTRAL-LABOR Lübecker Ärzte
Active
HbA1c
Basophile
Eosinophile
Thrombozyten
Lymphozyten
+ 3 more
ZERA GmbH Kalibrierlabor
Active
0,05 V
- Gleichstromstärke
dreiphasig 60 V; 120 V; 240 V
> 240 V
einphasig 0,002 V
+ 3 more
No matching labs found.