EN 50206-2

Metro and Tram Pantograph Testing

This test evaluates the performance characteristics of pantographs designed for metro and tram systems operating at lower speeds with different catenary configurations than main line railways. It assesses mechanical robustness, contact stability, wear rates, and electrical properties specific to urban rail environments with frequent acceleration and braking cycles. Public transport operators and rolling stock manufacturers depend on this accreditation to ensure pantograph reliability in urban transit networks. Accredited testing validates product safety and performance in metropolitan electrified rail systems across Europe.

What it measures

  • Contact force stability in urban operating conditions
  • Mechanical endurance under frequent acceleration/deceleration
  • Carbon strip or contact material wear rate
  • Electrical contact quality and resistance stability
  • Response to variable catenary tension
🇩🇪 DIN EN 50206-1 🇬🇧 BS EN 50206-1 🇫🇷 NF EN 50206-1 🇮🇹 UNI EN 50206-1 🇪🇸 UNE EN 50206-1 🇳🇱 NEN EN 50206-1 🇩🇪 DIN EN 50317 🇬🇧 BS EN 50317 🇫🇷 NF EN 50317 🇮🇹 UNI EN 50317 🇪🇸 UNE EN 50317 🇳🇱 NEN EN 50317
1,632 Accredited labs
19 Countries

Showing 101–125 of 875 labs

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-PL-11035-01-02 Essen, DE
ID136 > 140 DIN EN 143 DIN EN ISO 21149 DIN EN 13274-1 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-00 Hagen, DE
AB0-Blutgruppen-Merkmale Isoagglutinine (Serumeigenschaften) Rhesusmerkmale K-Merkmale + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile
DAkkS D-PL-18858-01-02 Krefeld, DE
DIN EN ISO 11357-2 DIN EN ISO 11357-3 DIN EN ISO 3071 DIN 54278-1 ISO 11890-2 + 3 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
DAkkS D-K-23327-01-01 Bad Camberg, DE
Metrologic Group GmbH, nalen von: Wernau, D Neuss, D ≤ 1515 mm Wetzlar, D S.p.A., Turin, I + 3 more
View Profile
DAkkS D-PL-17009-06-00 Wiesbaden, DE
DIN EN 60950-1 EN IEC 62368-1 DIN EN 60204-1 DIN EN 60825-1 DIN EN 61010-1 + 3 more
View Profile
DAkkS D-PL-17009-02-00 Mainz, DE
DIN 31051 DIN EN 1005-1 DIN EN 1993-1-1 DIN EN 1993-1 DIN EN 1993-6 + 3 more
View Profile
DAkkS D-PL-17009-07-02 Köln, DE
IEC 60335-1: 2010 IEC 60335-2-29 DIN EN 60335-2-29 IEC 60335-2-65 DIN EN 60335-2-65 + 3 more
View Profile
DAkkS D-PL-17009-09-01 München, DE
DIN 4420-1 DIN 4420-3 DIN EN 61347-1 ISO 12117-2 DIN 53449 + 3 more
View Profile
DAkkS D-PL-17009-02-01 Mainz, DE
VDE 0113-201 VDE 0113-202 DIN EN 60204-1 EN 61508-1: VDE 0803-1 + 3 more
View Profile

No matching labs found.

Industries

Metro and tram rolling stock manufacturers Urban public transport operators Pantograph component suppliers Vehicle type approval organizations

Related Standards

  • EN 50206-1 Railway pantographs — requirements for main line pantographs
  • EN 50317 Railway catenary — current collection quality measurement