IEC 60494-1

Railway Pantograph Head Type 1 Dimensions

This standard specifies the dimensional and geometric requirements for pantograph head contacts (Type 1) used on main line railway overhead contact lines. It ensures standardized contact strip profiles for compatibility with European catenary systems and interoperability of rolling stock across different railway networks. Manufacturers of pantograph heads and railway components require this accreditation to certify dimensional compliance and material properties. Standardized dimensions maintained through accredited testing enable reliable current collection and reduce wear inconsistencies across European railways.

What it measures

  • Pantograph head contact surface width and profile
  • Carbon or composite strip material thickness
  • Contact geometry and edge radii
  • Material hardness and electrical conductivity
  • Surface finish and contact pressure distribution
🇩🇪 DIN EN IEC 60494-2 🇬🇧 BS EN IEC 60494-2 🇫🇷 NF EN IEC 60494-2 🇮🇹 UNI EN IEC 60494-2 🇪🇸 UNE EN IEC 60494-2 🇳🇱 NEN EN IEC 60494-2 🇩🇪 DIN EN 50206-1 🇬🇧 BS EN 50206-1 🇫🇷 NF EN 50206-1 🇮🇹 UNI EN 50206-1 🇪🇸 UNE EN 50206-1 🇳🇱 NEN EN 50206-1
1,399 Accredited labs
17 Countries

Showing 226–250 of 800 labs

IGOS

Active
DAkkS D-PL-11282-01-00 Solingen, DE
ASTM B 117 ASTM B 368 ASTM G 85 DIN 8237 DIN 50014 + 3 more
View Profile
DAkkS D-PL-14095-03-02 Hamburg, DE
DIN 38402-A 12 DIN ISO 5667-5 (A 14) DIN EN ISO 5667-6 (A 15) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile
DAkkS D-ML-17347-01-00 Ulm, DE
Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Lymphozyten Leukozyten + 3 more
View Profile
DAkkS D-PL-19060-01-01 Wettenberg, DE
ISO 2178 ISO 4892-2: 2013-03 UNE-EN ISO 11998 BS EN ISO 16474-3:2021 ISO 6270-1 + 3 more
View Profile
DAkkS D-ML-18337-01-00 München, DE
Bacillus anthracis Antikörper Direkter Coombstest polyvalent Brucella spp. IgG, IgM Antikörper Francisella tularensis-Antikörper polyvalent, IgG, IgM + 3 more
View Profile

CalTeC

Active
DAkkS D-K-18657-01-01 Emmerthal, DE
Kurzschlussstrom 0,5 mA 0,1 V Füllfaktor Solarzellen* 25 % 0,01 mW THD U 0,1 % + 3 more
View Profile
DAkkS D-PL-19125-01-00 Bonn, DE
DIN EN IEC 60255-1 VDE 0435-300 DIN EN 60255-151 VDE 0435-3151 IEC 60255-151 + 3 more
View Profile
DAkkS D-PL-11307-01-00 Hamburg, DE
DIN EN ISO 12185 ASTM D 4052 DIN EN ISO 3405 ASTM D 86 DIN EN 13016-1 + 3 more
View Profile
DAkkS D-PL-14184-01-02 Fürth, DE
IEC 62321-2 DIN EN 61340-4-4 DIN EN 12472 DIN EN 16711-1 DIN EN 1264-5 + 3 more
View Profile
DAkkS D-PL-12085-01-01 Kaufbeuren, DE
IEC 61000-3-2: 2014 IEC 61000-3-3 IEC 61000-3-11: 2017 IEC 61000-3-12: 2011 IEC 61000-4-2: 2008 + 3 more
View Profile
DAkkS D-K-15061-01-00 Nettetal, DE
Härte* 20 HRA Härtevergleichsplatten 20 HRB 20 HRC 40 HRD + 3 more
View Profile
DAkkS D-K-15030-01-00 Villingen-Schwenningen, DE
Rillentiefe Pt und d 0,15 µm Tiefeneinstellnormalen > 12 µm Rauheit auf Geometrienormalen + 3 more
View Profile

Jakob Mooser

Active
DAkkS D-PL-12168-01-01 Egling / Thanning, DE
IEC 61000-6-1 VDE 0839-6-1 IEC 61000-6-2: 2005 VDE 0839-6-2 IEC 61000-6-3: 2006 + 3 more
View Profile
DAkkS D-K-21494-01-00 Weiden i. d. OPf., DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen Innen- und Tiefenmaße Konventioneller + 2 more
View Profile
DAkkS D-K-18423-01-00 Aschaffenburg, DE
Ebenheitsabweichung verkörperungen z.B. platten nach DIN 876:1984 Geradheitsabweichung ebener Flächen, z.B. + 3 more
View Profile

Johs. Boss

Active
DAkkS D-K-21417-01-01 Albstadt, DE
Außengewinde Flankendurchmesser 3 mm bis 100 mm 0,5 mm bis 6 mm) unsymmetrischem Profil schiedlichen Ausgabeständen gestattet. + 3 more
View Profile
DAkkS D-K-22268-01-01 Aschaffenburg, DE
− Längenmessmittel − Längenmessgeräte − Drehwinkel Vickers hardness test (ISO 6507) Länge + 3 more
View Profile
DAkkS D-ML-13135-03-01 Würzburg, DE
CD45 Percp+CD16+56+CD3 CD4 CD45 Percp+CD4+CD8 Adalimumab Anti-Adalimumab Antikörper + 3 more
View Profile

Jurjanz

Active
DAkkS D-K-15085-01-01 Schkeuditz, DE
Parallelendmaße aus 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße aus > 100 mm Messschieber für 1350 mm + 3 more
View Profile
DAkkS D-K-19781-01-02 Hagen, DE
Temperaturmessgrößen Widerstandsthermometer* Railway braking — urban guided transport Railway vehicle body structural requirem Widerstandssensor * + 3 more
View Profile
DAkkS D-K-17233-01-00 Hochdorf-Assenheim, DE
Härteprüfmaschinen nach 100 HBW Brinell- und 226 HBW messeinrichtungen von Härteprüfmaschinen + 3 more
View Profile
DAkkS D-K-18972-01-01 Hemmingen, DE
eingängige zylindrische Einstellnormale Lehrdorne Durchmesser 1 mm Prüfstifte + 3 more
View Profile
DAkkS D-ML-13391-01-00 Frankfurt am Main, DE
basophile, eosinophile, Granulozyten Differenzialblutbild Erythrozyten Erythrozytenverteilungsbreite (RDW) + 3 more
View Profile
DAkkS D-PL-12091-01-01 Forchtenberg, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-15052-01-01 Pfaffenhofen, DE
Gleichspannung 0 mV Messgeräte > 200 mV > 2 V bis 20 V > 20 V bis 200 V > 200 V bis 1000 V + 3 more
View Profile

No matching labs found.

Industries

Pantograph head manufacturers Carbon strip and contact material suppliers Railway rolling stock manufacturers Component type approval bodies

Related Standards

  • IEC 60494-2 Railway overhead lines — pantograph heads type 2
  • EN 50206-1 Railway pantographs — requirements for main line pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods

0 labs selected
Compare