IEC 60494-2

Railway Pantograph Head Type 2 Dimensions

This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.

What it measures

  • Type 2 pantograph head contact width and profile geometry
  • Carbon or composite strip material composition and thickness
  • Contact surface hardness and wear resistance
  • Electrical conductivity and contact resistance
  • Mechanical deflection under typical operating forces
🇩🇪 DIN EN IEC 60494-1 🇬🇧 BS EN IEC 60494-1 🇫🇷 NF EN IEC 60494-1 🇮🇹 UNI EN IEC 60494-1 🇪🇸 UNE EN IEC 60494-1 🇳🇱 NEN EN IEC 60494-1 🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2
1,632 Accredited labs
19 Countries

Showing 1,601–1,625 of 1,632 labs

DAkkS D-ML-13188-01-01 Limburg a. d. Lahn- Eschhofen, DE
Lysozym = Sexualhormon bindendes Prolaktin Freies Thyroxin 4 (FT4) Beta-Defensin 2 + 3 more
View Profile
DAkkS D-PL-20957-01-00 Nürnberg, DE
IEC 61000-6-1 IEC 61000-6-2: 2005 DIN EN 50155 VDE 0115-200 DIN EN 50121-3-2 + 3 more
View Profile

enveon

Active
DAkkS D-PL-21616-01-01 München, DE
VDE 0468-2-1 IEC 60068-2-1 VDE 0468-2-2 IEC 60068-2-2 DIN EN 60068-2-14 + 3 more
View Profile
DAkkS D-K-15019-01-01 Landkreis Fürstenfeldbruck, DE
Hochspannung - Wechselspannung Bereiche Rechteckspannung Amplitudenparameter + 3 more
View Profile

eumetron

Active
DAkkS D-K-15151-01-01 Aalen, DE
− Durchmesser − Parallelendmaße − Formabweichung − Strichmaße, Abstände − Virtuelle Koordinatenmessgeräte + 3 more
View Profile
DAkkS D-PL-14078-01-03 Wesseling, DE
DIN 19698-1 DIN 19698-2 DIN ISO 11464 DIN EN ISO 54321 DIN EN 12457-4 + 3 more
View Profile

europascal

Active
DAkkS D-K-15055-01-01 Hanau, DE
- Gleichspannung / Messgeräte > 0 V > 0,22 V > 2,2 V + 3 more
View Profile
DAkkS D-K-21048-01-00 Kirchzarten, DE
Positiver und negativer Positiver Überdruck p e 1) In den CMC sind die erweiterten Messu
View Profile

i2 FAST

Active
UKAS 10852 Hemel Hempstead, GB
BS 4401-1:1998 Using N008-1 based on BS EN ISO 12966-4 2015 N008-2 based on BS EN N011 based on BS 4401-9:1975 and BS 770- + 3 more
View Profile

iKM Service

Active
DAkkS D-K-21115-01-00 Zwickau, DE
Industrielle Messtechnik ≤ 860 mm GmbH, Oberkochen, D
View Profile

iLF Magdeburg

Active
DAkkS D-PL-18869-01-01 Magdeburg, DE
DIN EN ISO 9117-3 DIN EN ISO 9117-5 DIN EN ISO 1463 DIN EN ISO 2808 DIN EN ISO 2178 + 3 more
View Profile
DAkkS D-K-17060-01-00 Tettnang, DE
Taupunkttemperatur –0,91 bar bis Positiver und negativer Überdruck p *) (ein- oder mehrgängige + 3 more
View Profile
UKAS 1916 Hebden Bridge, GB
on BS 4401:Part 3:1970(1986) ISO 12966-1:2014 and ISO 12966-4 CH 4026 based on BS 5766:Part CH 4001 based on BS EN 12014- + 3 more
View Profile

ift Rosenheim

Active
DAkkS D-PL-11349-01-01 Rosenheim, DE
ASTM E 330/E 330M ASTM E 283/E283M DIN 4103-1 DIN 68706-1 UNE-EN 12211 + 3 more
View Profile
DAkkS D-PL-21129-01-03 Gießen, DE
DIN EN ISO 5667-1 (A 4) DIN ISO 5667-5 (A 14) DIN EN ISO 5667-3 (A 21) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile
DAkkS D-K-15219-01-02 Helmstadt, DE
Taupunkttemperatur fixpunktzellen Railway braking — urban guided transport Railway vehicle body structural requirem SPRT-Sensor + 3 more
View Profile
DAkkS D-K-19194-01-00 Idstein, DE
Absolutdruck p abs > 0,8 bar > 1,2 bar > 20 bar + 3 more
View Profile

iocto

Active
DAkkS D-K-21204-01-00 Hofheim am Taunus, DE
Taupunkttemperatur direktanzeigende −45 °C Railway vehicle body structural requirem Widerstandssensor direktanzeigende > 200 °C + 3 more
View Profile
DAkkS D-ML-13309-01-00 Dresden, DE
Basophile Eosinophile Erythrozyten Hämatokrit Leukozyten + 3 more
View Profile
DAkkS D-ML-19652-01-00 Frankfurt, DE
Großes Blutbild TSH Immunglobulin E 25-OH-Vitamin D Vitamin B12 + 3 more
View Profile
DAkkS D-ML-13067-01-00 Berlin, DE
Basophile Eosinophile Erythrozyten Hämatokrit Leukozyten (Zellzahl) + 3 more
View Profile

qbig

Active
DAkkS D-K-21619-01-00 Leer, DE
Durchflussmess- 13 m³/h - Hochspannungsmessgrößen > 25 m³/h Volumendurchfluss > 40 m³/h + 3 more
View Profile

seca

Active
DAkkS D-K-22590-02-01 Hamburg, DE
nichtselbsttätige elektronische Waagen − Waagen
View Profile
DAkkS D-K-21353-01-01 Manching-Oberstimm, DE
Absolutdruck 10 hPa Relativdruck −1 000 hPa Durchfluss von Gasen + 3 more
View Profile
DAkkS D-PL-12064-01-01 Bonn, DE
DIN EN 55016-1-4 VDE 0877-16-1-4 DIN EN 55016-2-1 VDE 0877-16-2-1 DIN EN 55016-2-2 + 3 more
View Profile

No matching labs found.

Industries

Metro and tram pantograph head manufacturers Urban transit rolling stock manufacturers Contact material and strip suppliers Metro system operators and maintainers

Related Standards

  • IEC 60494-1 Railway overhead lines — pantograph heads
  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods

0 labs selected
Compare