IEC 62846

Railway Pantograph Interaction with Overhead Contact Line

This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.

What it measures

  • Contact force between pantograph head and overhead line
  • Arcing and electrical discontinuities during contact
  • Pantograph head wear rate and material loss
  • Dynamic lift and pressure stability at various speeds
  • Compatibility with different catenary wire geometries
🇩🇪 DIN EN 50206 🇬🇧 BS EN 50206 🇫🇷 NF EN 50206 🇮🇹 UNI EN 50206 🇪🇸 UNE EN 50206 🇳🇱 NEN EN 50206 🇩🇪 DIN EN 50367 🇬🇧 BS EN 50367 🇫🇷 NF EN 50367 🇮🇹 UNI EN 50367 🇪🇸 UNE EN 50367 🇳🇱 NEN EN 50367
1,632 Accredited labs
19 Countries

Showing 601–625 of 875 labs

DAkkS D-K-11200-01-00 Gosheim, DE
Lehrdorne Durchmesser 1 mm Lehrringe Prüfstifte Messschieber für 0 mm + 3 more
View Profile
DAkkS D-K-15212-01-01 Leubingen, DE
Parallelendmaße aus 0,5 mm Parallelendmaße aus Keramik nach 0,5 mm Wolframkarbid nach 0,5 mm DIN EN ISO 3650:1999 + 3 more
View Profile
DAkkS D-K-15146-01-01 Schöneck-Kilianstädten, DE
− Parallelendmaße − Durchmesser − Längenmessmittel Railway brake — magnetic track brakes (U − Längenmessgeräte + 3 more
View Profile
DAkkS D-ML-17443-01-00 Dessau-Roßlau, DE
WBC (Leukozyten) RBC (Erythrocyten) HGB (Hb) HCT (Hk) PLT (Thrombozyten) + 3 more
View Profile
DAkkS D-K-23061-01-01 Lichtenau, DE
Druck 50 mbar Absolutdruck Pabs > 1,3 bar > 2,5 bar > 0,6 bar + 3 more
View Profile

SysKal

Active
DAkkS D-K-21604-01-00 Steinheim an der Murr, DE
Hexagon Metrology Raumdiagonale von GmbH, Wetzlar, D ≤ 1500 mm Polyworks, Software von InnovMetric, Lindau, D PowerINSPECT, Software + 3 more
View Profile
DAkkS D-K-19425-01-01 Stolberg, DE
- Gleichspannung > 0,1 V > 10 V > 100 V - Gleichstromstärke + 3 more
View Profile
DAkkS D-PL-11119-01-00 Leipzig, DE
ISO 5-3 ISO 12647-1 ISO 13655
View Profile
DAkkS D-PL-11239-01-05 Chemnitz, DE
ISO 3074 DIN EN ISO 1833-4 DIN EN ISO 1833-5 DIN EN ISO 1833-6 DIN EN ISO 1833-7 + 3 more
View Profile
DAkkS D-PL-17142-01-01 Stahnsdorf, DE
DIN ISO 11466 UNE-EN 12880 ÖNORM EN 12457-4 ISO 10523 DIN EN 27888 + 3 more
View Profile

TAK CERT

Active
DAkkS D-K-20800-01-01 Bonn, DE
− Scheinwerfer-Einstell-Prüfsystem − Abgasmessgeräte für Fremdzündungsmotor − Abgasmessgeräte für Kompressionszündun Railway brake — magnetic track brakes (U nur Vor-Ort-Kalibrierungen + 3 more
View Profile

TC Laser

Active
DAkkS D-PL-22493-01-00 Eppertshausen, DE
DIN EN 50689 VDE 0837-689 DIN 56912 DIN EN 60825-1 VDE 0837-1 + 3 more
View Profile
DAkkS D-K-15024-01-01 Heusweiler, DE
- Gleichspannung / Messgeräte 0,1 mV > 220 mV > 2,2 V + 3 more
View Profile
DAkkS D-K-15097-01-01 Pinneberg, DE
Elektrische Messgrößen Gleichstrom- und Niederfrequenzmessgröße Railway brake — magnetic track brakes (U − Gleichspannung − Gleichstromstärke + 3 more
View Profile

TIRA

Active
DAkkS D-K-17684-01-00 Schalkau, DE
Kraft (WPM) Kraftmesseinrichtungen von Werkstoffprüfmaschinen Acoustics — tonality assessment (DIN 456 Länge (WPM) + 3 more
View Profile
DAkkS D-K-11048-01-02 Darmstadt, DE
Railway braking — thermal analysis (EN 1 Railway — traction effort and braking fo Railway vehicle dynamics — on-track test Railway brake disc acoustic emissions (E Railway wheel squeal and curve noise (EN + 3 more
View Profile
DAkkS D-ML-14063-01-00 München, DE
Staphylokokken Treponema pallidum (Cardiolipin Antikörper) Legionella spp. Salmonellen, Shigellen, Yersinia + 3 more
View Profile
DAkkS D-PL-14063-03-00 München, DE
ISO 15835-2 DIN EN ISO 6506-1 DIN EN ISO 15630-1 DIN EN ISO 15630-3 IEC 62301 + 3 more
View Profile
DAkkS D-K-22502-01-01 Ilmenau, DE
& 2: 2008 Leuchtdichte L / vom Typ L3 Standard Normfarbwertanteile x , y / LED-basierte Farb- und + 3 more
View Profile

Tektronix

Active
DAkkS D-K-17602-01-01 Köln, DE
- Gleichspannung Quellen - Gleichstromstärke Stromzangen - Gleichstromwiderstand + 3 more
View Profile
DAkkS D-K-18197-01-00 Martinroda, DE
Taupunkttemperatur Railway braking — urban guided transport Widerstandssensor –40 °C bis > 5 °C bis + 3 more
View Profile

Teramess

Active
DAkkS D-K-18666-01-02 Germering, DE
Absolutdruck p 0,015 bar abs > 1,7 bar > 70 bar > 100 bar + 3 more
View Profile
DAkkS D-K-18316-01-00 Backnang, DE
Gleichspannung 0 mV Messgeräte 10 mV Wechselspannung 0,22 mV > 220 mV > 2,2 V + 3 more
View Profile
DAkkS D-K-22318-01-00 Neu Wulmstorf, DE
Positiver Überdruck p e > 70 bar Überdruck p (ein- oder mehrgängige
View Profile
DAkkS D-K-15070-01-01 Kirchzarten, DE
- Gleichspannung / Messgeräte Quellen Hochspannung - Gleichstromstärke + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway infrastructure operators Public transport authorities Catenary system suppliers Rail maintenance and depot operators

Related Standards

  • EN 50206 Railway applications - Pantographs - Rules for testing and validation
  • EN 50367 Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead line
  • IEC 61853 Railway applications - Testing and measurement of pantograph and overhead line interaction

Other Test Methods

0 labs selected
Compare