IEC 62846

Railway Pantograph Interaction with Overhead Contact Line

This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.

What it measures

  • Contact force between pantograph head and overhead line
  • Arcing and electrical discontinuities during contact
  • Pantograph head wear rate and material loss
  • Dynamic lift and pressure stability at various speeds
  • Compatibility with different catenary wire geometries
🇩🇪 DIN EN 50206 🇬🇧 BS EN 50206 🇫🇷 NF EN 50206 🇮🇹 UNI EN 50206 🇪🇸 UNE EN 50206 🇳🇱 NEN EN 50206 🇩🇪 DIN EN 50367 🇬🇧 BS EN 50367 🇫🇷 NF EN 50367 🇮🇹 UNI EN 50367 🇪🇸 UNE EN 50367 🇳🇱 NEN EN 50367
1,399 Accredited labs
17 Countries

Showing 1–25 of 800 labs

Techmetrics

Active
DAkkS Professional D-K-22606-01-01 Winnenden, DE
absolute Feuchte Taupunkttemperatur Taupunktspiegel Taupunkttransmitter Railway bogies — wheelsets and bogies st + 3 more
View Profile Verified

1A CAL

Active
DAkkS D-K-15115-01-00 Kassel, DE
- Gleichspannung Josephson-Josephson Multimeter Quellen > 0,2 V Spannungsnormale + 3 more
View Profile
DAkkS D-K-15158-01-00 Haiger, DE
Sound intensity — scanning method (ISO 9 Härteprüfmaschinen Knoop- und 70 HR15N 42 HR30N + 3 more
View Profile

3D Service

Active
DAkkS D-K-18164-01-01 Partenstein, DE
Münchingen, D CAM 2, Software von Holos, Software von Carl Metrologic, Software von Metrologic Group ≤ 9090 mm + 3 more
View Profile
DAkkS D-K-21981-01-00 Konstanz, DE
8tree Scanner / 0 mm bis 100 mm Laterale Größe von Tiefenmaß/ -unterstand (Härteskalen HV0,01
View Profile
DAkkS D-K-12115-01-00 Minden, DE
Absolutdruck p abs positiver Überdruck Positiver Überdruck p e Überdruck p + 3 more
View Profile
DAkkS D-PL-20374-01-00 Mühlhausen, DE
DIN EN 13018 DIN EN IEC 60068-2-11 DIN EN 60068-2-14 IEC 60068-2-29 DIN EN 60068-2-30 + 3 more
View Profile

AIP

Active
DAkkS D-K-21076-01-01 Haldenwang, DE
Railway brake — anti-slide device (UIC 5 Railway brake — magnetic track brakes (U Railway brakes — conditions for homologa Messgeräte im Kraftfahrwesen − Abgasmessgeräte für Fremdzündungsmotor + 3 more
View Profile
DAkkS D-K-18095-01-00 Karlsfeld, DE
/ Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V + 3 more
View Profile

AL-PRO

Active
DAkkS D-PL-11316-01-00 Großheide, DE
IEC 61400-12-1 * IEC 61400-12-5 * IEC 61400-50 * IEC 61400-50-1 * IEC 61400-50-2 * + 1 more
View Profile
DAkkS D-PL-11003-07-00 Görlitz, DE
DIN 27201-5 DIN 25043-1 DIN 25043-2 DIN EN 13272 DIN EN 13272-1 + 3 more
View Profile
DAkkS D-K-15032-02-00 Weiterstadt, DE
Railway brake — magnetic track brakes (U auch als Vor-Ort-Kalibrierung Rillentiefe Pt auf 0,2 µm Tiefeneinstellnormalen Rauheit auf Raunormalen + 3 more
View Profile

AQRAT

Active
DAkkS D-K-15060-01-00 Dettingen unter Teck, DE
Messschieber für 0 mm Außen-, Innen- und > 500 mm > 1000 mm Tiefenmessschieber * 0 mm Sondermessschieber 0 mm + 3 more
View Profile
DAkkS D-K-19792-01-01 Alsdorf, DE
Gleichstromleistung / Messgeräte Wirkleistung Leistungsfaktor - Gleichspannung + 3 more
View Profile
DAkkS D-K-19342-01-02 Holzkirchen, DE
Taupunkttemperatur Railway braking — urban guided transport Temperaturtransmitter Widerstandssensor *) –30 °C + 3 more
View Profile
DAkkS D-K-18731-01-01 Manching, DE
- Gleichspannung / Messgeräte 1 µV Quellen > 1 V + 3 more
View Profile
DAkkS D-PL-11244-01-01 Berlin, DE
EN 14033-3 ISO 9611 ISO 11201
View Profile
DAkkS D-K-19562-01-01 Kaufbeuren, DE
Durchmesser 1 mm 510 mm Rundheitsabweichung 1 mm Parallelitätsabweichung Rundheitsabweichung + 3 more
View Profile
DAkkS D-ML-19804-01-00 Hamburg, DE
Cyclosporin A Everolimus FK 506 (Tacrolimus) Sirolimus 6-Methylmercaptopurin + 3 more
View Profile
DAkkS D-ML-13314-03-00 Lübeck, DE
Fra(X)-Syndrom, FXTAS (FMR1) Friedreich Ataxie (FXN) DRPLA (ATN1) Huntington Krankheit (HTT) Huntington-like (TBP, JPH3) + 3 more
View Profile
DAkkS D-ML-13314-04-00 Kiel, DE
Aldosteron 11-Desoxycorticosteron 11-Desoxycortisol 17-Hydroxypregnenolon 17-Hydroxyprogesteron + 3 more
View Profile
DAkkS D-K-19592-01-00 Pforzheim, DE
Tensile testing of metallic materials (I Feuchtemessgrößen 15 % *) > 30 % Railway bogies — wheelsets and bogies st Temperaturmessgrößen + 3 more
View Profile
DAkkS D-K-17702-01-00 Garching, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu nichtselbsttätige + 2 more
View Profile
DAkkS D-K-15079-01-00 Alsdorf, DE
Absolutdruck p abs 0,015 bar > 2 bar > 42 bar Absolutdruck Pabs 1 bar; 2 bar + 3 more
View Profile
DAkkS D-PL-22860-01-01 Reutlingen, DE
DIN 55635 VDE 0468-2-14 VDE 0468-2-1 VDE 0468-2-5 DIN EN 60068-2-30 + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway infrastructure operators Public transport authorities Catenary system suppliers Rail maintenance and depot operators

Related Standards

  • EN 50206 Railway applications - Pantographs - Rules for testing and validation
  • EN 50367 Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead line
  • IEC 61853 Railway applications - Testing and measurement of pantograph and overhead line interaction

Other Test Methods

0 labs selected