IEC 62846
Railway Pantograph Interaction with Overhead Contact Line
This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.
What it measures
- Contact force between pantograph head and overhead line
- Arcing and electrical discontinuities during contact
- Pantograph head wear rate and material loss
- Dynamic lift and pressure stability at various speeds
- Compatibility with different catenary wire geometries
🇩🇪
DIN EN 50206
🇬🇧
BS EN 50206
🇫🇷
NF EN 50206
🇮🇹
UNI EN 50206
🇪🇸
UNE EN 50206
🇳🇱
NEN EN 50206
🇩🇪
DIN EN 50367
🇬🇧
BS EN 50367
🇫🇷
NF EN 50367
🇮🇹
UNI EN 50367
🇪🇸
UNE EN 50367
🇳🇱
NEN EN 50367
1,632
Accredited labs
19
Countries
Showing 851–875 of 875 labs
eurofins Umwelt West
Active
DIN 19698-1
DIN 19698-2
DIN ISO 11464
DIN EN ISO 54321
DIN EN 12457-4
+ 3 more
halstrup-walcher
Active
Positiver und negativer
Positiver Überdruck p e
1) In den CMC sind die erweiterten Messu
iLF Magdeburg
Active
DIN EN ISO 9117-3
DIN EN ISO 9117-5
DIN EN ISO 1463
DIN EN ISO 2808
DIN EN ISO 2178
+ 3 more
Taupunkttemperatur
–0,91 bar bis
Positiver und negativer
Überdruck p *)
(ein- oder mehrgängige
+ 3 more
ift Rosenheim
Active
ASTM E 330/E 330M
ASTM E 283/E283M
DIN 4103-1
DIN 68706-1
UNE-EN 12211
+ 3 more
DIN EN ISO 5667-1 (A 4)
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-3 (A 21)
DIN EN ISO 19458 (K 19)
DIN 19643-1
+ 3 more
Taupunkttemperatur
fixpunktzellen
Railway braking — urban guided transport
Railway vehicle body structural requirem
SPRT-Sensor
+ 3 more
Absolutdruck p
abs
> 0,8 bar
> 1,2 bar
> 20 bar
+ 3 more
iocto
Active
Taupunkttemperatur
direktanzeigende −45 °C
Railway vehicle body structural requirem
Widerstandssensor
direktanzeigende > 200 °C
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten
+ 3 more
Großes Blutbild
TSH
Immunglobulin E
25-OH-Vitamin D
Vitamin B12
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten (Zellzahl)
+ 3 more
qbig
Active
Durchflussmess- 13 m³/h
- Hochspannungsmessgrößen
> 25 m³/h
Volumendurchfluss
> 40 m³/h
+ 3 more
Absolutdruck
10 hPa
Relativdruck
−1 000 hPa
Durchfluss von Gasen
+ 3 more
steep GmbH EMV-Zentrum
Active
DIN EN 55016-1-4
VDE 0877-16-1-4
DIN EN 55016-2-1
VDE 0877-16-2-1
DIN EN 55016-2-2
+ 3 more
Blutungszeit
5-Hydroxyindolessigsäure
Aminosäuren
Carbohydrate-Deficient-Transferrin
Everolimus
+ 3 more
tech-team Kalibrierlabor
Active
Gleichspannung 0,01 V
Messgeräte 0,33 V
3,3 V
330 V
Gleichstromstärke 30 µA
+ 3 more
velotech.de
Active
DIN EN ISO 4210-1
DIN EN 15194: 2018
DIN 33946
DIN EN 15918
DIN EN ISO 11243
+ 3 more
ISO 534
ISO 536
rs11887534
HABP2-Gen (c.1601G>A) rs7080536
ISO 1974
+ 3 more
Labor Wisplinghoff
Active
Liste aller Untersuchungsverfahren
Webpräsenz des Medizinischen Laboratoriu
Cannabinoide (Cannabinol, Cannabidiol)
Cannabinoide (THC)
Cannabinoide (THC-COOH)
+ 3 more
Überörtliche Berufsausübungsgemeinschaft Fachärzte für Laboratoriumsmedizin und Mikrobiologie
Active
Adrenalin
Amiodaron, Desmethylamiodaron
CDT
Amiodaron, Desethylamiodaron
Dopamin
+ 3 more
11-Desoxycortisol
Acylcarnitine
Agomelatin
Albendazolsulfoxid
a-Hydroxy-Alprazolam
+ 3 more
No matching labs found.