EN 15610

Rail and Wheel Surface Roughness Measurement

This test measures micro and macro-scale surface roughness on railway wheels and rails to assess their contribution to rolling noise generation. Surface irregularities on the wheel-rail interface are primary sources of railway noise, making this measurement essential for noise control and environmental compliance. The test uses standardized contact filtering and measurement zones to quantify roughness parameters that correlate with noise emissions. Railway infrastructure managers, wheel manufacturers, and rolling stock operators use this test to monitor equipment maintenance and optimize noise reduction strategies. Accredited testing provides validated data for environmental impact assessments and compliance with EU noise directives.

What it measures

  • Macroscopic roughness (wavelength 3–300 mm)
  • Microscopic roughness (wavelength 0.1–3 mm)
  • Peak-to-valley surface irregularities
  • Root mean square roughness values (Ra, Rz, Rq)
  • Wavelength-specific roughness spectra
🇩🇪 DIN EN ISO 3274 🇬🇧 BS EN ISO 3274 🇫🇷 NF EN ISO 3274 🇮🇹 UNI EN ISO 3274 🇪🇸 UNE EN ISO 3274 🇳🇱 NEN EN ISO 3274 🇩🇪 DIN EN 13674-1 🇬🇧 BS EN 13674-1 🇫🇷 NF EN 13674-1 🇮🇹 UNI EN 13674-1 🇪🇸 UNE EN 13674-1 🇳🇱 NEN EN 13674-1
1,516 Accredited labs
17 Countries

Showing 726–750 of 799 labs

DAkkS D-ML-13258-03-00 Mainz, DE
5-Hydroxyindolessigsäure Amitriptylin/Nortriptylin Cyclosporin A Gesamt-Itraconazol Metanephrine, Normetanephrine + 3 more
View Profile
DAkkS D-PL-12061-01-01 Offenbach am Main, DE
IEC 60061-1 IEC 60061-2 IEC 60238 IEC 61184 IEC 60400 + 3 more
View Profile
DAkkS D-PL-19465-01-00 Darmstadt, DE
Myopathie, Nemaline (TyP1, 3-10: ASTM E 23-18 ASTM D 1322 Toxizität UGT1A1-Gen rs3064744, rs414832 DIN EN 1789 + 3 more
View Profile
DAkkS D-PL-21133-01-00 Versmold, DE
DIN SPEC 91323 DIN EN 1815 DIN 8959 DIN 8959 Ber. 1
View Profile

Vectoflow

Active
DAkkS D-K-21643-02-00 Gilching, DE
am Standort Vectoflow Windtunnel A, Frie Strömungsgeschwindigkeit von Gasen 15 m/s bis > 38 m/s
View Profile
DAkkS D-PL-14368-01-01 Schwäbisch Gmünd, DE
DIN EN ISO 1463 DIN EN ISO 3497 DIN EN 14518 DIN EN ISO 18452 IEC 62642-3 + 3 more
View Profile
DAkkS D-ML-13393-01-00 Karlsruhe, DE
Blutbild, kleines (Erythrozyten, Leukozy Erythrozyten Leukozyten Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-K-18737-01-01 Jena, DE
− Permanentes Laboratorium Positionen und Abstände gleichgerichteter Kanten positionen von Strukturen (Hartschichtmasken) + 3 more
View Profile
DAkkS D-K-17723-01-00 Wiesthal, DE
Koordinatenmessgeräte von <7000 mm under-Edge, UK INCA3D, Software von Inspect 3D, Cholet, F + 3 more
View Profile
DAkkS D-K-15105-01-00 Klingenberg, DE
Positiver und −1 bar bis −0,03 bar Positiver und negativer (ein- oder mehrgängige > −0,03 bar bis > 0,15 bar bis + 3 more
View Profile
DAkkS D-K-17410-01-01 Korbußen, DE
− Parallelendmaße − Längenmessmittel − Durchmesser − Formabweichung − Gewinde + 3 more
View Profile
DAkkS D-K-20130-01-00 Meissen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen verwendete Abkürzungen: 1) In den CMC sind die erweiterten Messu + 2 more
View Profile

Waagen-Jöhnk

Active
DAkkS D-K-19520-01-00 Dätgen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) verwendete Abkürzungen:
View Profile
DAkkS D-K-19038-01-00 Rimbach, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) verwendete Abkürzungen:
View Profile
DAkkS D-K-17685-01-00 Hardegsen, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen verwendete Abkürzungen:
View Profile
DAkkS D-PL-21231-01-00 Marienheide, DE
DIN EN ISO 5667-1 (A 4) * DIN 38402-A 12 * DIN 38402-A 13 * DIN EN ISO 5667-3 (A 21) * DIN 38402-A 30 * + 3 more
View Profile
DAkkS D-PL-14015-01-02 Erding, DE
DIN EN 2561 DIN EN ISO 14126 DIN EN ISO 14125 DIN EN 2563 DIN 53504 + 3 more
View Profile
DAkkS D-K-15006-01-00 Gießen, DE
Steuerungssoftware Messvolumen mit einer Werth Messtechnik ≤ 2330 mm GmbH, Gießen, D Werth Messtechnik ≤ 600 mm Werth Messtechnik ≤ 150 mm
View Profile
DAkkS D-PL-21876-01-01 Dortmund, DE
DIN IEC 60060-1 VDE 0432- 1 IEC 60270 VDE 0434 DIN EN 61243-1 + 3 more
View Profile
DAkkS D-K-14054-01-00 Hörstel, DE
Kohlenstoffmonoxid *) Kohlenstoffdioxid Propan *) Stickstoffmonoxid Distickstoffmonoxid + 3 more
View Profile
DAkkS D-K-20386-01-00 Meppen, DE
Parallelendmaße aus 0,5 mm DIN EN ISO 3650:1999 Einstelldorne Durchmesser 3 mm Durchmesser 5 mm + 3 more
View Profile
DAkkS D-K-15040-01-00 Wuppertal, DE
Charpy impact test (ISO 148-1) nichtselbsttätigen elektronischen Ersatzlastverfahren (Staffelverfahren) + 1 more
View Profile
DAkkS D-K-21902-01-00 Wilsdruff ST Kesselsdorf, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-ML-18420-01-00 Lübeck, DE
HbA1c Basophile Eosinophile Thrombozyten Lymphozyten + 3 more
View Profile
DAkkS D-K-15103-01-01 Königswinter, DE
0,05 V - Gleichstromstärke dreiphasig 60 V; 120 V; 240 V > 240 V einphasig 0,002 V + 3 more
View Profile

No matching labs found.

Industries

Railway infrastructure and track operators Wheel and axle manufacturing Rolling stock manufacturers Rail grinding and maintenance contractors Environmental and noise control consultants

Related Standards

  • ISO 3274 Geometrical product specifications (GPS) — Surface texture: Profile method — Nominal characteristics of contact (stylus) instruments
  • EN 13674-1 Railway applications — Track — Rail — Part 1: Vignole railway rails 46 kg/m and 54 kg/m
  • EN 15313 Railway applications — Wheels and wheelsets — Acceptance criteria for wheels — Safety and quality requirements

Other Test Methods

0 labs selected
Compare