EN 15610

Rail and Wheel Surface Roughness Measurement

This test measures micro and macro-scale surface roughness on railway wheels and rails to assess their contribution to rolling noise generation. Surface irregularities on the wheel-rail interface are primary sources of railway noise, making this measurement essential for noise control and environmental compliance. The test uses standardized contact filtering and measurement zones to quantify roughness parameters that correlate with noise emissions. Railway infrastructure managers, wheel manufacturers, and rolling stock operators use this test to monitor equipment maintenance and optimize noise reduction strategies. Accredited testing provides validated data for environmental impact assessments and compliance with EU noise directives.

What it measures

  • Macroscopic roughness (wavelength 3–300 mm)
  • Microscopic roughness (wavelength 0.1–3 mm)
  • Peak-to-valley surface irregularities
  • Root mean square roughness values (Ra, Rz, Rq)
  • Wavelength-specific roughness spectra
🇩🇪 DIN EN ISO 3274 🇬🇧 BS EN ISO 3274 🇫🇷 NF EN ISO 3274 🇮🇹 UNI EN ISO 3274 🇪🇸 UNE EN ISO 3274 🇳🇱 NEN EN ISO 3274 🇩🇪 DIN EN 13674-1 🇬🇧 BS EN 13674-1 🇫🇷 NF EN 13674-1 🇮🇹 UNI EN 13674-1 🇪🇸 UNE EN 13674-1 🇳🇱 NEN EN 13674-1
1,273 Accredited labs
15 Countries

Showing 651–675 of 1,273 labs

UKAS 29622 Chelmsford, GB
(HSG 264, 2012)
View Profile
UKAS 1119 Enfield, GB
staining based on HSG 248 (HSG 248) – 2021 (PCM) based on HSG 248
View Profile
UKAS 9681 Hextable, GB
(HSG 248) – 2021 ASB04 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 2569 Gateshead, GB
staining based on HSG 248 (HSG 248) – 2021 (PCM) based on HSG 248 3492, ISO14966 and HSG 248 DIN EN 14629 + 3 more
View Profile
DAkkS D-K-15223-01-00 Wertheim, DE
Taupunkttemperatur Fixpunktzellen *) thermometer (SPRT) *) meter, direkt anzeigende thermometer und + 3 more
View Profile
DAkkS D-ML-14413-03-01 München, DE
Cryptococcus neoformans Cardiolipin AK Escherichia coli K1-AG Haemophilus influenzae Metromec Software AG + 3 more
View Profile
UKAS 0227 Poole, GB
Plain ring gauges (taper) Plain gap gauges (parallel) Plain plug gauges (taper) LENGTH ANGLE + 3 more
View Profile

MBS

Active
DAkkS D-PL-12159-01-00 Krefeld, DE
DIN EN ISO 16484-5 DIN EN ISO 16484-6 IEC 62386-101 IEC 62386-102 IEC 62386-103 + 3 more
View Profile

MCV

Active
ENAC LC10.124 Collbató, ES
0,005 l/min ≤ Q ≤ 50 l/min 0,5 m3/h≤ Q ≤ 2,8 m3/h 0,6 m3/h  Q  2,8 m3/h 20 m3/h  Q  30 m3/h 30 m3/h < Q  70 m3/h + 3 more
View Profile
DAkkS D-PL-19548-01-03 Waldkraiburg, DE
DIN EN 13018 DIN EN 50289-1-2 DIN EN 50289-1-3 DIN EN 50289-1-4 DIN EN 50289-1-5 + 3 more
View Profile
DAkkS D-ML-13341-01-01 Berlin, DE
17-OH-Carbazepin Amiodaron, Desmethylamiodaron Amitriptylin Clobazam Clomipramin + 3 more
View Profile
DAkkS D-K-20515-01-00 Filderstadt, DE
Temperaturmessgrößen auch direktanzeigend 35 °C direktanzeigende > 200 °C auch direktanzeigend Temperaturmessgrößen −35 °C + 3 more
View Profile
ENAC LC10.163 Badalona, ES
Rangos de caudal (m3/h): 1 m3/h ≤ Q < 25
View Profile
ENAC LC10.236 San Ginés, ES
1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 5 5 kg 10 kg 20 kg 100 kg 200 kg 500 kg 1000 kg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 5 + 2 more
View Profile

METROPACK

Active
COFRAC 1-6986 Reims, FR
ISO 11607-1 ASTM F1886 BS EN ISO 11607-1:2020+A11 NF EN 868-5 annexe D ASTM F88 DIN EN 12758 + 3 more
View Profile
ACCREDIA 00540 Napoli, IT
DIN EN ISO 12945-2 DIN EN ISO 5403-1 DIN EN ISO 2060 DIN EN ISO 13937-1 DIN EN ISO 11642 + 3 more
View Profile
COFRAC 1-7500 Nanterre, FR
DIN EN 14511-2 DIN EN 14511-3 DIN EN 14511-4 DIN EN 14825 NF EN 16147
View Profile
DAkkS D-K-18366-01-01 Schweinfurt, DE
1350 mm Innen- und Tiefenmaße * > 300 mm Tiefenmessschieber * 0 mm Höhenmessschieber * 0 mm + 3 more
View Profile

MLL MVZ

Active
DAkkS D-ML-13228-01-00 München, DE
Berliner-Blau-Reaktion Naphthylacetat-Esterase Pappenheim-Färbung Peroxidase-Reaktion Schnellfärbung (Diff-Quick) + 3 more
View Profile
DAkkS D-ML-13178-01-01 Mönchengladbach, DE
CRP Cystatin C HbA1c Großes Blutbild Kleines Blutbild + 3 more
View Profile
UKAS 0228 Wimborne, GB
Plain plug gauges (parallel) length bars) LENGTH (continued) Micrometers (enzephalomyopathische Form + 3 more
View Profile
DAkkS D-PL-11241-01-01 Eberswalde, DE
DIN EN 50178: 1998 DIN EN ISO 2813 DIN EN ISO 4628-4 DIN EN ISO 10456 DIN EN ISO 12572 + 3 more
View Profile
DAkkS D-K-17552-01-01 Berlin, DE
Drehmoment * 0,2 N∙m > 10 N∙m bis Kalibriereinrichtungen > 100 N∙m Drehmomentschlüssel, 0,2 N∙m + 3 more
View Profile

MR COMP

Active
DAkkS D-PL-13383-01-00 Gelsenkirchen, DE
IEC 62570 DIN 13273-7
View Profile
UKAS 1625 Wellingborough, GB
on BS 4401:Part 3:1970(1986) ISO 936:1998 BS ISO 21528-2:2017 BS ISO 16649-2:2001 ISO 6888-1 + 3 more
View Profile

No matching labs found.

Industries

Railway infrastructure and track operators Wheel and axle manufacturing Rolling stock manufacturers Rail grinding and maintenance contractors Environmental and noise control consultants

Related Standards

  • ISO 3274 Geometrical product specifications (GPS) — Surface texture: Profile method — Nominal characteristics of contact (stylus) instruments
  • EN 13674-1 Railway applications — Track — Rail — Part 1: Vignole railway rails 46 kg/m and 54 kg/m
  • EN 15313 Railway applications — Wheels and wheelsets — Acceptance criteria for wheels — Safety and quality requirements

Other Test Methods

0 labs selected
Compare