ISO 2631-1 applied to rail vehicles

Whole-Body Vibration Evaluation for Railway Passenger Comfort

This test applies ISO 2631-1 whole-body vibration assessment methodology specifically to railway passenger comfort evaluation, measuring and analysing human exposure to vibration during train operation. The method uses frequency-weighted acceleration measurements and comfort indices to objectively quantify the vibrational environment experienced by passengers in railway vehicles. It is commonly used alongside EN 12299 to provide complementary assessment of ride quality, supporting vehicle design validation and operational certification. Accreditation ensures correct application of international human factors standards to railway operations and reliable passenger comfort assessment.

What it measures

  • Frequency-weighted acceleration in vertical direction
  • Frequency-weighted acceleration in horizontal directions
  • Vibration dose value (VDV)
  • Exposure time and cumulative vibration effects
  • Passenger comfort perception indices
🇩🇪 DIN EN ISO 2631-1 🇬🇧 BS EN ISO 2631-1 🇫🇷 NF EN ISO 2631-1 🇮🇹 UNI EN ISO 2631-1 🇪🇸 UNE EN ISO 2631-1 🇳🇱 NEN EN ISO 2631-1 🇩🇪 DIN EN 12299 🇬🇧 BS EN 12299 🇫🇷 NF EN 12299 🇮🇹 UNI EN 12299 🇪🇸 UNE EN 12299 🇳🇱 NEN EN 12299
1,632 Accredited labs
19 Countries

Showing 76–100 of 875 labs

DAkkS D-K-19708-01-00 Paderborn, DE
- Gleichspannung Quellen > 0,10 V > 1 V > 10 V - Gleichstromstärke + 3 more
View Profile
DAkkS D-PL-12030-01-02 Plattling, DE
DIN EN 55016-2 VDE 0877-16-2-1 VDE 0877-16-2-2 VDE 0877-16-2-3 EN IEC 61000-4 + 3 more
View Profile
DAkkS D-ML-13325-01-00 Cottbus, DE
Oligosaccharide Chromatographie (Gaschromatograpie Cannabinoide (THC-COOH) Amphetamine Opiate + 3 more
View Profile
DAkkS D-PL-11062-01-02 Bielefeld, DE
DIN EN ISO 13934-1 DIN EN ISO 13935-2 DIN EN ISO 13937-2 DIN EN ISO 13937-3 DIN EN 14682 + 3 more
View Profile
DAkkS D-K-18066-01-00 Hechingen, DE
Vickers hardness test (ISO 6507) Temperaturmessgrößen –70 °C Railway braking — urban guided transport Thermometer mit > –40 °C Widerstandssensor * + 3 more
View Profile

Carl Zeiss

Active
DAkkS D-PL-12125-01-01 Oberkochen, DE
DIN EN 60601-1 IEC 60601-1 DIN EN 60601-1-1 IEC 60601-1-1 IEC 80601-2-77 + 3 more
View Profile
DAkkS D-K-21703-01-00 Oberkochen, DE
Carl Zeiss Industrielle ≤ 3818 mm Oberkochen, D 1) In den CMC sind die erweiterten Messu Carl Zeiss Industrielle ≤ 20 m Auswertesoftware Messvolumen mit + 3 more
View Profile
DAkkS D-K-15007-01-01 Oberkochen, DE
Parallelendmaße 50 mm DIN EN ISO 3650:1999 Thermischer Ausdeh- Maximale Dimension Bandbreite Höhe: 80 mm + 3 more
View Profile
DAkkS D-PL-12037-01-02 Jena, DE
DIN EN 61010-1 VDE 0411-1 IEC 61010-1 : 2010 DIN EN 60825-1 VDE 0837 + 3 more
View Profile
DAkkS D-K-12037-01-01 Jena, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 40 mm Parallelendmaße * ≥ 100 mm Strichmaßstäbe 0 mm + 3 more
View Profile

CeGaT

Active
DAkkS D-ML-13206-01-01 Tübingen, DE
angeborener Chromosomensatz (Imbalancen im Genom, (Duplikationen/Del SNRPN-Region 15q11-13 UPD15 (UBE3A) SMN1; Spinale Muskelatrophie + 3 more
View Profile

Cenata

Active
DAkkS D-ML-21205-01-01 Tübingen, DE
Pränatales Screening auf Chromosomenstörungen (Trisomie 21, Trisomie 18, Trisomie 13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
View Profile
DAkkS D-ML-13008-09-01 Berlin, DE
Whole genome sequencing (WGS: SNV, CNV/SV)
View Profile
DAkkS D-ML-13008-01-00 Berlin, DE
Thyreoidea stimulierendes (TSH) 17-α-OH-Progesteron (17-OH-P) Immunreaktives Trypsin + 3 more
View Profile

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile
DAkkS D-PL-14010-01-04 Bensheim, DE
DIN 38402-A 13 DIN ISO 5667-5 (A 14) DIN 38402-A 30 DIN 19643-1 ISO 5667-11 + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-K-11081-02-01 Chemnitz, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 auch Vor-Ort Kalibrierung bahntypischer –0,26 mm + 3 more
View Profile
DAkkS D-PL-11072-01-01 Freiberg, DE
DIN EN ISO 9012 ISO 22967 ISO 22968 (SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 + 3 more
View Profile
DAkkS D-K-17567-01-01 Lauf a. d. Pegnitz, DE
(ein- und mehrgängige zylindrische Außen- und metrischem Profil) Außengewinde Nenndurchmesser Flankendurchmesser 1 mm + 3 more
View Profile
DAkkS D-PL-11060-03-05 Stuttgart, DE
DIN EN ISO 5667-3 DIN EN ISO 15587-2 DIN EN 12457-4 DIN EN 13346 DIN EN 13657 + 3 more
View Profile
DAkkS D-PL-17438-01-04 Stuttgart, DE
IEC 60335-1: 2010 IEC 60335-2-2 IEC 60335-2-3 DIN EN 60335-2-3: 2002 IEC 60335-2-4 + 3 more
View Profile
DAkkS D-K-18255-01-00 Amberg, DE
Drehmoment 0,01 N·m Railway — traction effort and braking fo 0,1 N·m
View Profile
DAkkS D-K-21738-01-01 Köln, DE
- Gleichspannung Messgeräte > 330 mV > 3,3 V > 33 V > 330 V + 3 more
View Profile

No matching labs found.

Industries

Railway vehicle manufacturing Passenger train operators High-speed rail services Urban transit and metro systems Vehicle ergonomics and comfort design

Related Standards

  • ISO 2631-1 Mechanical vibration and shock — evaluation of human exposure to whole-body vibration — Part 1: general requirements
  • EN 12299 Railway applications — ride comfort for passengers — measurement and evaluation
  • ISO 2631-4 Mechanical vibration and shock — evaluation of human exposure to whole-body vibration — Part 4: guidelines for the evaluation of the effects of vibration and rotational motion on passenger comfort

Other Test Methods

0 labs selected
Compare