ISO 2631-1 applied to rail vehicles

Whole-Body Vibration Evaluation for Railway Passenger Comfort

This test applies ISO 2631-1 whole-body vibration assessment methodology specifically to railway passenger comfort evaluation, measuring and analysing human exposure to vibration during train operation. The method uses frequency-weighted acceleration measurements and comfort indices to objectively quantify the vibrational environment experienced by passengers in railway vehicles. It is commonly used alongside EN 12299 to provide complementary assessment of ride quality, supporting vehicle design validation and operational certification. Accreditation ensures correct application of international human factors standards to railway operations and reliable passenger comfort assessment.

What it measures

  • Frequency-weighted acceleration in vertical direction
  • Frequency-weighted acceleration in horizontal directions
  • Vibration dose value (VDV)
  • Exposure time and cumulative vibration effects
  • Passenger comfort perception indices
🇩🇪 DIN EN ISO 2631-1 🇬🇧 BS EN ISO 2631-1 🇫🇷 NF EN ISO 2631-1 🇮🇹 UNI EN ISO 2631-1 🇪🇸 UNE EN ISO 2631-1 🇳🇱 NEN EN ISO 2631-1 🇩🇪 DIN EN 12299 🇬🇧 BS EN 12299 🇫🇷 NF EN 12299 🇮🇹 UNI EN 12299 🇪🇸 UNE EN 12299 🇳🇱 NEN EN 12299
1,632 Accredited labs
19 Countries

Showing 1,601–1,625 of 1,632 labs

DAkkS D-ML-13188-01-01 Limburg a. d. Lahn- Eschhofen, DE
Lysozym = Sexualhormon bindendes Prolaktin Freies Thyroxin 4 (FT4) Beta-Defensin 2 + 3 more
View Profile
DAkkS D-PL-20957-01-00 Nürnberg, DE
IEC 61000-6-1 IEC 61000-6-2: 2005 DIN EN 50155 VDE 0115-200 DIN EN 50121-3-2 + 3 more
View Profile

enveon

Active
DAkkS D-PL-21616-01-01 München, DE
VDE 0468-2-1 IEC 60068-2-1 VDE 0468-2-2 IEC 60068-2-2 DIN EN 60068-2-14 + 3 more
View Profile
DAkkS D-K-15019-01-01 Landkreis Fürstenfeldbruck, DE
Hochspannung - Wechselspannung Bereiche Rechteckspannung Amplitudenparameter + 3 more
View Profile

eumetron

Active
DAkkS D-K-15151-01-01 Aalen, DE
− Durchmesser − Parallelendmaße − Formabweichung − Strichmaße, Abstände − Virtuelle Koordinatenmessgeräte + 3 more
View Profile
DAkkS D-PL-14078-01-03 Wesseling, DE
DIN 19698-1 DIN 19698-2 DIN ISO 11464 DIN EN ISO 54321 DIN EN 12457-4 + 3 more
View Profile

europascal

Active
DAkkS D-K-15055-01-01 Hanau, DE
- Gleichspannung / Messgeräte > 0 V > 0,22 V > 2,2 V + 3 more
View Profile
DAkkS D-K-21048-01-00 Kirchzarten, DE
Positiver und negativer Positiver Überdruck p e 1) In den CMC sind die erweiterten Messu
View Profile

i2 FAST

Active
UKAS 10852 Hemel Hempstead, GB
BS 4401-1:1998 Using N008-1 based on BS EN ISO 12966-4 2015 N008-2 based on BS EN N011 based on BS 4401-9:1975 and BS 770- + 3 more
View Profile

iKM Service

Active
DAkkS D-K-21115-01-00 Zwickau, DE
Industrielle Messtechnik ≤ 860 mm GmbH, Oberkochen, D
View Profile

iLF Magdeburg

Active
DAkkS D-PL-18869-01-01 Magdeburg, DE
DIN EN ISO 9117-3 DIN EN ISO 9117-5 DIN EN ISO 1463 DIN EN ISO 2808 DIN EN ISO 2178 + 3 more
View Profile
DAkkS D-K-17060-01-00 Tettnang, DE
Taupunkttemperatur –0,91 bar bis Positiver und negativer Überdruck p *) (ein- oder mehrgängige + 3 more
View Profile
UKAS 1916 Hebden Bridge, GB
on BS 4401:Part 3:1970(1986) ISO 12966-1:2014 and ISO 12966-4 CH 4026 based on BS 5766:Part CH 4001 based on BS EN 12014- + 3 more
View Profile

ift Rosenheim

Active
DAkkS D-PL-11349-01-01 Rosenheim, DE
ASTM E 330/E 330M ASTM E 283/E283M DIN 4103-1 DIN 68706-1 UNE-EN 12211 + 3 more
View Profile
DAkkS D-PL-21129-01-03 Gießen, DE
DIN EN ISO 5667-1 (A 4) DIN ISO 5667-5 (A 14) DIN EN ISO 5667-3 (A 21) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile
DAkkS D-K-15219-01-02 Helmstadt, DE
Taupunkttemperatur fixpunktzellen Railway braking — urban guided transport Railway vehicle body structural requirem SPRT-Sensor + 3 more
View Profile
DAkkS D-K-19194-01-00 Idstein, DE
Absolutdruck p abs > 0,8 bar > 1,2 bar > 20 bar + 3 more
View Profile

iocto

Active
DAkkS D-K-21204-01-00 Hofheim am Taunus, DE
Taupunkttemperatur direktanzeigende −45 °C Railway vehicle body structural requirem Widerstandssensor direktanzeigende > 200 °C + 3 more
View Profile
DAkkS D-ML-13309-01-00 Dresden, DE
Basophile Eosinophile Erythrozyten Hämatokrit Leukozyten + 3 more
View Profile
DAkkS D-ML-19652-01-00 Frankfurt, DE
Großes Blutbild TSH Immunglobulin E 25-OH-Vitamin D Vitamin B12 + 3 more
View Profile
DAkkS D-ML-13067-01-00 Berlin, DE
Basophile Eosinophile Erythrozyten Hämatokrit Leukozyten (Zellzahl) + 3 more
View Profile

qbig

Active
DAkkS D-K-21619-01-00 Leer, DE
Durchflussmess- 13 m³/h - Hochspannungsmessgrößen > 25 m³/h Volumendurchfluss > 40 m³/h + 3 more
View Profile

seca

Active
DAkkS D-K-22590-02-01 Hamburg, DE
nichtselbsttätige elektronische Waagen − Waagen
View Profile
DAkkS D-K-21353-01-01 Manching-Oberstimm, DE
Absolutdruck 10 hPa Relativdruck −1 000 hPa Durchfluss von Gasen + 3 more
View Profile
DAkkS D-PL-12064-01-01 Bonn, DE
DIN EN 55016-1-4 VDE 0877-16-1-4 DIN EN 55016-2-1 VDE 0877-16-2-1 DIN EN 55016-2-2 + 3 more
View Profile

No matching labs found.

Industries

Railway vehicle manufacturing Passenger train operators High-speed rail services Urban transit and metro systems Vehicle ergonomics and comfort design

Related Standards

  • ISO 2631-1 Mechanical vibration and shock — evaluation of human exposure to whole-body vibration — Part 1: general requirements
  • EN 12299 Railway applications — ride comfort for passengers — measurement and evaluation
  • ISO 2631-4 Mechanical vibration and shock — evaluation of human exposure to whole-body vibration — Part 4: guidelines for the evaluation of the effects of vibration and rotational motion on passenger comfort

Other Test Methods

0 labs selected
Compare