ISO 5348

Accelerometer Mechanical Mounting Methods

ISO 5348 specifies the mechanical mounting requirements and installation methods for accelerometers used in vibration measurement and monitoring applications. Proper mounting is critical because accelerometer resonance and damping characteristics are strongly influenced by how the device is attached to the test structure. Industries including aerospace, automotive, mechanical engineering, and maintenance rely on this standard to ensure measurement accuracy and repeatability in vibration diagnostics. Accreditation to this standard demonstrates that a laboratory understands the physical factors affecting transducer performance and can provide traceable, reliable vibration data. Correct mounting practices are fundamental to valid vibration measurement across all frequency ranges.

What it measures

  • Transverse sensitivity effects of mounting
  • Frequency response accuracy with different mounting methods
  • Resonance frequency stability
  • Mechanical coupling effects
  • Temperature compensation for mounted accelerometers
🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954 🇪🇸 UNE EN ISO 6954 🇳🇱 NEN EN ISO 6954
1,591 Accredited labs
17 Countries

Showing 201–225 of 1,591 labs

Brehmer

Active
DAkkS D-PL-20176-01-00 Nümbrecht, DE
DIN EN 60068-2-14 DIN EN 60068-2-30 DIN EN IEC 60068-2-38 DIN EN 60068-2-64 DIN EN 60068-2-78 + 3 more
View Profile
UKAS 7864 Bridgend, GB
(HSG 248) – 2021 P10.2 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 0357 Watford, GB
DIN EN 12664 DIN EN 12939 DIN EN 12667 ISO 8301 BS 2782:Part 6:Method 632A:1993 + 3 more
View Profile
UKAS 0295 Norwich, GB
(HSG 264, 2012)
View Profile
UKAS 10636 Earby, GB
ISO 20768:2018)
View Profile
UKAS 2245 Uxbridge, GB
Based on ISO 10312:2019 and ISO SOP 16 by XRD (ISO BS EN
View Profile
DAkkS D-PL-12084-01-00 Hamburg, DE
IEC 60945 IEC 61162-1 IEC 61162-2 IEC 61162-450 IEC 61162-460 + 3 more
View Profile
DAkkS D-K-15063-01-00 Berlin, DE
Radioaktivität 50 Bq/m³ Radon-222- 100 Bq/m³ tration in Luft 200 Bq/m³ + 3 more
View Profile
DAkkS D-PL-11075-01-01 Berlin, DE
DIN EN ISO 2808 DIN EN ISO 3219-2 DIN EN ISO 3838 DIN EN 933-1 DIN EN 933-4 + 3 more
View Profile
DAkkS D-K-11075-08-00 Berlin, DE
Conformity assessment — requirements for Railway composite brake blocks — require 0,2 kN 0,4 kN 100 kN + 3 more
View Profile
DAkkS D-K-15013-01-00 Bergisch Gladbach, DE
Beschleunigung stoßförmig (sin 2 Impuls) > 1500 m/s Schwingungsaufnehmer
View Profile
DAkkS D-ML-13381-01-01 Berlin, DE
NRBC-Normoblasten Anteil unreifer Retikulozyten Erythrozyten DELTA-He Leukozyten + 3 more
View Profile
DAkkS D-ML-13381-01-00 Berlin, DE
Blutungszeit PFA ADP Blutungszeit PFA EPI PFA-P2Y Erythrozyten Hämatokrit + 3 more
View Profile

Bureau Cicero

Active
RvA I225 Houten, NL
# EN 116-97 NEN 4400-2 # ISO 13736 NEN 4400-1 #ISO 6618 + 1 more
View Profile
DAkkS D-PL-12024-03-02 Türkheim, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-3: 2006 VDE 0847-4-3 IEC 61000-4-4: 2012 + 3 more
View Profile
DAkkS D-PL-12024-06-02 Nürnberg, DE
EN IEC 61000-4 DIN EN IEC 61000 VDE 0847-4 DIN EN 55016-2 DIN EN IEC 61000-6 + 3 more
View Profile
RvA L663 Eindhoven, NL
IEC 18045 IEC 15408-1
View Profile
DAkkS D-PL-18304-01-00 Bielefeld, DE
DIN EN ISO 898-1 DIN EN ISO 898-2 ISO 898-1 ISO 898-2 DIN EN ISO 6892-2 + 3 more
View Profile
UKAS 2361 Newtownabbey, GB
(HSG 248) – 2021 (PCM) based on HSG 248 SOP 5, based on HSG 248 SOP 4, based on HSG 248
View Profile
DAkkS D-K-20476-01-01 Dortmund, DE
/ Messgeräte Radiometrie 100 µW/cm² stärkemessgeräte UV-A 365nm Linearität der + 3 more
View Profile
DAkkS D-K-20113-01-00 Wuppertal, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) verwendete Abkürzungen:
View Profile
ACCREDIA 01402 Civitella in Valdichiana, IT
ETSI EN 301 489-1: V2.2.3 EN 61000-3-2 and EN 61000-3-3 IEC 61000-6-1 IEC 61000-4-4: 2012 1.4 Electrostatic Discharge EN 61000-4 + 3 more
View Profile
UKAS 0156 Congresbury, GB
(HSG 264, 2012) HSG 227 (2004)) Safety Executive guides HSG 264 (2012) and App 3 of HSG 227 (HSG 248) – 2021 + 3 more
View Profile
ENAC LC10.071 Boadilla del Monte, ES
(3 ± 0,5)  10-2 mol/mol (5 ± 0,5)  10- (5 ± 0,5)  10-2 mol/mol - 80 ˚C a 200 ˚C - 20 ˚C a < 23 ˚C 23 ˚C a 40 ˚C > 40 ˚C - 20 ˚C a 60 ˚C + 2 more
View Profile

No matching labs found.

Industries

Aerospace and aircraft maintenance Automotive and engine testing Machinery condition monitoring Mechanical engineering and R&D Vibration diagnostics and predictive maintenance

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers – Calibration of accelerometers
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW and nominal speeds between 120 and 15000 r/min
  • ISO 10816-1 Mechanical vibration – Evaluation of machine vibration by measurements on non-rotating parts

Other Test Methods

0 labs selected
Compare