ISO 13373-1

Machinery Vibration Condition Monitoring

ISO 13373-1 establishes general procedures for vibration-based condition monitoring and diagnostics of machines to detect developing faults and assess operational health. This standard defines measurement strategies, signal processing methods, and diagnostic logic applicable to diverse machine populations in industrial and operational environments. Maintenance departments, predictive maintenance service providers, and asset management teams use this methodology to optimise equipment uptime and plan cost-effective interventions. Accreditation ensures technically sound and reproducible monitoring data that supports evidence-based maintenance decisions and equipment reliability improvement.

What it measures

  • Vibration amplitude and frequency content across machine operating range
  • Broadband and narrowband vibration signatures
  • Trend progression and rate of change
  • Fault-specific frequencies and harmonics
  • Machine health status classification
🇩🇪 DIN EN ISO 13373-2 🇬🇧 BS EN ISO 13373-2 🇫🇷 NF EN ISO 13373-2 🇮🇹 UNI EN ISO 13373-2 🇪🇸 UNE EN ISO 13373-2 🇳🇱 NEN EN ISO 13373-2 🇩🇪 DIN EN ISO 10816-1 🇬🇧 BS EN ISO 10816-1 🇫🇷 NF EN ISO 10816-1 🇮🇹 UNI EN ISO 10816-1 🇪🇸 UNE EN ISO 10816-1 🇳🇱 NEN EN ISO 10816-1
1,591 Accredited labs
17 Countries

Showing 76–100 of 1,591 labs

ITC

Active
ENAC LE004 Castellón de la Plana, ES
UNE-EN ISO 10545-2 UNE-EN ISO 10545-3 ASTM C373 UNE-EN ISO 10545-4 UNE-EN ISO 10545-5 + 3 more
View Profile

AIMEN

Active
ENAC LE158 Porriño, ES
UNE-EN ISO 3452-1 UNE-EN ISO 5817 UNE-EN ISO 23277 UNE-EN ISO 10042 UNE-EN ISO 13919-1 + 3 more
View Profile
ENAC LC10.028 Valladolid, ES
0 mV ≤ U < 200 mV 0,2 V ≤ U < 2 V 2 V ≤ 1 mV ≤ U < 220 mV 0,22 V ≤ U < 2,2 V 2,2 0 mV ≤ U ≤ 100 mV 0,1 V < U ≤ 1 V 1 V < 0 μA ≤ I < 200 μA 0,2 mA ≤ I < 2 mA 2 mA 0 μA ≤ I < 220 μA 0,22 mA ≤ I < 2,2 mA 2 + 3 more
View Profile
ENAC LE2422 Toledo, ES
UNE-EN 772-11 UNE 136029 DIN 4772:1979 DIN EN 16510-2-4 DIN EN 17539 + 3 more
View Profile
ACCREDIA 02321 Roma, IT
IEC 15408-1 IEC 18045 IEC 18367 IEC 20543 IEC 20004
View Profile
ENAC LE723 Castellón de la Plana, ES
EPA 26 UNE-EN 15259 UNE-EN 14791 UNE-EN 13284-1 UNE EN 1911 + 3 more
View Profile
DAkkS D-PL-22228-01-01 Regensburg, DE
ISO 11451-1 ISO 11451-2: 2015 ISO 11451-4: 2013 ISO 11452-1 ISO 11452-2: 2019 + 3 more
View Profile
DAkkS D-PL-22228-06-01 Villingen-Schwenningen, DE
ISO 11452-2: 2019 ISO 11452-4: 2020 ISO 11452-5: 2002 ISO 11452-8: 2015 ISO 10605 + 3 more
View Profile

AWE

Active
UKAS 1854 Reading, GB
(HSG 248) – 2021 LQP007 based on HSG 248 LQP003 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 0477 Gosport, GB
the guidance of GPG 14 PERSONAL DOSE EQUIVALENT: RESPONSE:
View Profile
UKAS 0078 Portchester, GB
DC Resistance CFH-Gen, Macula-Degeneration DC RESISTANCE (continued) DC VOLTAGE DC VOLTAGE (continued) + 3 more
View Profile

Accon

Active
DAkkS D-PL-19965-01-00 Greifenberg, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
UKAS 2418 Cleckheaton, GB
(HSG 248) – 2021 (PCM) based on HSG 248 staining based on HSG 248 (HSG 264, 2012) Appendix 5 of HSG 227
View Profile
UKAS 0483 Hemel Hempstead, GB
ISO 11654 BS EN ISO 10140-2:2021 ISO 7171 ISO 354 BS EN ISO 10140-3:2021 + 3 more
View Profile
UKAS 0653 Milton Keynes, GB
Sound Calibrators Pistonphones based: level Microphones + 2 more
View Profile
UKAS 8504 Glasgow, GB
(HSG 264:2012) HSG 227 Appendix 5: By HSG 227 Appendix 3: By
View Profile
UKAS 9064 Paignton, GB
DIN EN ISO 11127-6 DIN EN 13727 1) BS EN ISO 11930:2019+ 2) QMIC WI 22, based on BS EN
View Profile
DAkkS D-K-19342-01-02 Holzkirchen, DE
Taupunkttemperatur Railway braking — urban guided transport Temperaturtransmitter Widerstandssensor *) –30 °C + 3 more
View Profile

Air Surveys

Active
UKAS 0553 Wandsworth, GB
(HSG 248) – 2021 APP 7 based on HSG 248 (PCM) based on HSG 248 (PCM) based on HSG 248) APP 15 based on HSG 248 + 2 more
View Profile
UKAS 7486 Irvinestown, GB
BS EN ISO 16283-1:2014+A1:2017BS EN ISO BS EN ISO 140-4:1998 ISO 1407 ISO 7171 BS EN ISO 9972:2015 + 1 more
View Profile
UKAS 0232 Manchester, GB
(HSG 264, 2012)
View Profile
UKAS 2054 Manchester, GB
(HSG 248) – 2021 AEC 1 based on HSG 248 (PCM) based on HSG 248 AEC 6 based on HSG 248
View Profile
DAkkS D-K-18731-01-01 Manching, DE
- Gleichspannung / Messgeräte 1 µV Quellen > 1 V + 3 more
View Profile
UKAS 4376 Alton, GB
(HSG 248) – 2021 (PCM) based on HSG 248
View Profile
UKAS 0681 Writtle, GB
(HSG 248) – 2021 (PCM) based on HSG 248 staining based on HSG 248 (HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile

No matching labs found.

Industries

Predictive maintenance services Manufacturing and process control Rotating machinery operations Thermal and hydro power plants Asset management and facility operations

Related Standards

  • ISO 13373-2 Condition monitoring and diagnostics of machines—Vibration condition monitoring—Part 2: Guidance on the interpretation of vibration diagnostics
  • ISO 10816-1 Mechanical vibration—Evaluation of machine vibration by measurements on non-rotating parts—Part 1: General guidelines
  • ISO 20816-1 Mechanical vibration—Measurement and evaluation of vibration of rotating machinery—Part 1: General guidelines

Other Test Methods

0 labs selected
Compare