ISO 10816-1
Machine Vibration Evaluation on Non-Rotating Parts
ISO 10816-1 provides general principles and procedures for measuring vibration on non-rotating parts of machines to assess mechanical condition and reliability. This foundational standard establishes measurement methodology, instrumentation requirements, and evaluation zones applicable across diverse machine types. Manufacturers, service providers, and plant operators use this test to monitor equipment health and prevent unexpected failures. Accreditation ensures consistent, comparable vibration measurements that support predictive maintenance strategies and machine acceptance criteria.
What it measures
- Vibration velocity in mm/s (RMS and peak)
- Frequency range (typically 10–1000 Hz)
- Vibration magnitude in vertical, horizontal directions
- Machine operating condition classification
- Alarm and alert threshold zones
🇩🇪
DIN EN ISO 10816-3
🇬🇧
BS EN ISO 10816-3
🇫🇷
NF EN ISO 10816-3
🇮🇹
UNI EN ISO 10816-3
🇪🇸
UNE EN ISO 10816-3
🇳🇱
NEN EN ISO 10816-3
🇩🇪
DIN EN ISO 13373-1
🇬🇧
BS EN ISO 13373-1
🇫🇷
NF EN ISO 13373-1
🇮🇹
UNI EN ISO 13373-1
🇪🇸
UNE EN ISO 13373-1
🇳🇱
NEN EN ISO 13373-1
1,817
Accredited labs
19
Countries
Showing 326–350 of 1,817 labs
BS ISO 488:2008, 2446:2008 and
on BS 4401:Part 3:1970(1986)
BS 696-2:1989 (superseded and
BS ISO 6731:2010
ISO BS EN 3727-1:2002
+ 3 more
Electrolytes in blood serum:
Enzymes in blood serum:
(Chlamydia pneumoniae, Mycoplasma
urine:
Hormones in blood serum:
+ 1 more
Carl Zeiss
Active
DIN EN 60601-1
IEC 60601-1
DIN EN 60601-1-1
IEC 60601-1-1
IEC 80601-2-77
+ 3 more
Carl Zeiss IQS Deutschland
Active
Carl Zeiss Industrielle ≤ 3818 mm
Oberkochen, D
1) In den CMC sind die erweiterten Messu
Carl Zeiss Industrielle ≤ 20 m
Auswertesoftware Messvolumen mit
+ 3 more
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
Cavendish Laboratories
Active
(cdt), Deletion an Pos 117
(HSG 248) – 2021
(PCM) based on HSG 248
BS 6068-4.12:1998 (withdrawn)
CeGaT
Active
angeborener Chromosomensatz
(Imbalancen im Genom, (Duplikationen/Del
SNRPN-Region 15q11-13 UPD15
(UBE3A)
SMN1; Spinale Muskelatrophie
+ 3 more
Cenata
Active
Pränatales Screening auf
Chromosomenstörungen
(Trisomie 21, Trisomie 18, Trisomie
13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
DIN EN 12207
DIN EN 12208
DIN EN 1026
DIN EN 12210
BS EN 14351-1:2006+A2:2016
+ 3 more
Chamois Metrology
Active
Calibration of pressure
Gas pressure (gauge)
Gas Pressure (Differential)
common mode pressure of 3.5
Hydraulic pressure (gauge)
+ 3 more
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
IEC 60068-2-30
DIN EN 60068-2-30
+ 3 more
Whole genome sequencing (WGS:
SNV, CNV/SV)
Thyreoidea stimulierendes
(TSH)
17-α-OH-Progesteron
(17-OH-P)
Immunreaktives Trypsin
+ 3 more
Liquid-in-glass thermometers
ASTM D4052 (Digital density
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN 38402-A 30
DIN 19643-1
ISO 5667-11
+ 3 more
Chemring Countermeasures
Active
IEC 60068-2-2
BS 2011:2.1 Ca:1977
IEC 60068-2-30
MIL-STD 331B: 1994:
DIN EN 60068-2-78
+ 3 more
Cirrus Research
Active
Sound Calibrators
Sound Level Meters
One-third octave band filters
(HSG 248) – 2021
SRV-002 based on HSG 248
(PCM) based on HSG 248
No matching labs found.