ISO 10816-1
Machine Vibration Evaluation on Non-Rotating Parts
ISO 10816-1 provides general principles and procedures for measuring vibration on non-rotating parts of machines to assess mechanical condition and reliability. This foundational standard establishes measurement methodology, instrumentation requirements, and evaluation zones applicable across diverse machine types. Manufacturers, service providers, and plant operators use this test to monitor equipment health and prevent unexpected failures. Accreditation ensures consistent, comparable vibration measurements that support predictive maintenance strategies and machine acceptance criteria.
What it measures
- Vibration velocity in mm/s (RMS and peak)
- Frequency range (typically 10–1000 Hz)
- Vibration magnitude in vertical, horizontal directions
- Machine operating condition classification
- Alarm and alert threshold zones
🇩🇪
DIN EN ISO 10816-3
🇬🇧
BS EN ISO 10816-3
🇫🇷
NF EN ISO 10816-3
🇮🇹
UNI EN ISO 10816-3
🇪🇸
UNE EN ISO 10816-3
🇳🇱
NEN EN ISO 10816-3
🇩🇪
DIN EN ISO 13373-1
🇬🇧
BS EN ISO 13373-1
🇫🇷
NF EN ISO 13373-1
🇮🇹
UNI EN ISO 13373-1
🇪🇸
UNE EN ISO 13373-1
🇳🇱
NEN EN ISO 13373-1
1,591
Accredited labs
17
Countries
Showing 276–300 of 1,591 labs
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
Cavendish Laboratories
Active
(cdt), Deletion an Pos 117
(HSG 248) – 2021
(PCM) based on HSG 248
BS 6068-4.12:1998 (withdrawn)
CeGaT
Active
angeborener Chromosomensatz
(Imbalancen im Genom, (Duplikationen/Del
SNRPN-Region 15q11-13 UPD15
(UBE3A)
SMN1; Spinale Muskelatrophie
+ 3 more
Cenata
Active
Pränatales Screening auf
Chromosomenstörungen
(Trisomie 21, Trisomie 18, Trisomie
13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
DIN EN 12207
DIN EN 12208
DIN EN 1026
DIN EN 12210
BS EN 14351-1:2006+A2:2016
+ 3 more
Chamois Metrology
Active
Calibration of pressure
Gas pressure (gauge)
Gas Pressure (Differential)
common mode pressure of 3.5
Hydraulic pressure (gauge)
+ 3 more
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
IEC 60068-2-30
DIN EN 60068-2-30
+ 3 more
Whole genome sequencing (WGS:
SNV, CNV/SV)
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
Chemring Countermeasures
Active
IEC 60068-2-2
BS 2011:2.1 Ca:1977
IEC 60068-2-30
MIL-STD 331B: 1994:
DIN EN 60068-2-78
+ 3 more
(HSG 248) – 2021
SRV-002 based on HSG 248
(PCM) based on HSG 248
CoMech Metrology
Active
Chronic progressive external
Depth
Internal
Dial gauges and dial test
Caliper
+ 3 more
Coesfeld
Active
Kraft (WPM)
Belastungseinrichtungen von
Werkstoffprüfmaschinen
Länge (WPM) 0,5 mm
messeinrichtungen von
+ 3 more
simulation.
parameters and ranges)
digital and analogue
Compli Group
Active
DC CURRENT
DC Resistance
Oscilloscope Calibration
DC VOLTAGE
CAPACITANCE
+ 3 more
Messgeräte 0,001 V
> 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
BS EN ISO 16283-1:2014+A1:2017BS EN ISO
BS EN ISO 16283-2:2020
HTM 08-01 - 2013
BS EN ISO 140-4:1998
BS EN ISO 717-2:2020
+ 3 more
DIN EN 933-11
DIN EN 12390-3
DIN EN 933-3
DIN EN 12390-7
DIN EN 12697-5
+ 3 more
DC CURRENT
LENGTH
DC Resistance
DC VOLTAGE
Cold junction compensation
+ 3 more
No matching labs found.