ISO 10816-3
Industrial Machine Vibration Assessment (>15 kW)
ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.
What it measures
- Vibration velocity in mm/s (RMS) on bearing pedestals
- Measurement at specified speed ranges and operating conditions
- Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
- Vertical and horizontal vibration components
- Trend analysis and transient response
🇧🇪
NBN EN ISO 10816-1
🇩🇪
DIN EN ISO 10816-1
🇬🇧
BS EN ISO 10816-1
🇫🇷
NF EN ISO 10816-1
🇮🇹
UNI EN ISO 10816-1
🇪🇸
UNE EN ISO 10816-1
🇳🇱
NEN EN ISO 10816-1
🇧🇪
NBN EN ISO 20816-3
🇩🇪
DIN EN ISO 20816-3
🇬🇧
BS EN ISO 20816-3
🇫🇷
NF EN ISO 20816-3
🇮🇹
UNI EN ISO 20816-3
4,140
Accredited labs
21
Countries
Showing 2,576–2,600 of 4,140 labs
Streptokokken
Bakterien und Pilze
Dermatophyten
Mykobakterien
Enterobacteriaceae
+ 3 more
Ethanol
Creatinin
Digitoxin
HbA1c
Aldosteron
+ 3 more
Melutec Metrology
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Winkel
- Direktanzeigende Thermometer
+ 3 more
Digoxin
HbA1c
Glucose
AFP
CA 19-9
+ 3 more
Ethanol
Digoxin
Glucose
CEA
Gentamicin
+ 3 more
Wechselspannung 10 mV
zu 25 mV bis 1 V (Sekundär)
Beschleunigung
amplitude (Betrag)
− Beschleunigung
+ 3 more
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Flüssigkeitsvolumen
Kolbenbüretten 5 mL
Kolbenbüretten 10 mL
+ 2 more
CFH-Gen, Macula-Degeneration
PRESSURE
ELECTRICAL
DC VOLTAGE
AC CURRENT
+ 3 more
Metrolution
Active
Oberkochen, D
Metrosoft CM, Software einer Raumdiagona
AG, Chur, CH ≤ 3333 mm
GmbH, Wetzlar, D
AG, Chur, CH ≤ 7500 mm
+ 1 more
Mettler-Toledo
Active
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Absolutdruck p *
verwendete Abkürzungen:
+ 3 more
MeßTechnikNord
Active
Salt spray / neutral salt fog test (ISO
Railway braking — urban guided transport
Railway vehicle body structural requirem
- Gleichspannung
- Wechselspannung
+ 3 more
DIN EN 10228-2
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
+ 3 more
DIN ISO 16649-2
DIN EN ISO 4833-1
ISO 11731
DIN EN ISO 6888-1
ISO 16649-2
+ 3 more
Microlab Consulting Srl
Active
DIN EN ISO 11885
DIN EN ISO 15587-2
DIN EN 13657
DIN EN ISO 17294-2
DIN EN 15934
+ 3 more
Micropathology
Active
Pseudomonas aeruginosa
Hepatitis-B-surface-Antigen
Hepatitis B-e-Antigen
Neisseria gonorrhoeae DNA
Rhinovirus RNA
+ 3 more
Microtech Gefell
Active
10 Hz
Akustische Messgrößen
Empfangsübertragungsmaß
> 100 Hz
> 10 kHz
+ 3 more
Microtech Services (Wessex)
Active
# = 100 A
ISO 7251
ISO 6888-3
Total Aerobic Colony Count at 22C and 37
2) A:6c based on ISO 21528-1:2017 by mos
+ 1 more
Microvida
Active
Massaspectrometrie
Pre-analyse
Moleculaire diagnostiek d.m.v. PCR
Fenotypische karakterisatie
Antilichaambepaling d.m.v. immuno- assay
+ 3 more
Microvida
Active
Massaspectrometrie
Pre-analyse
Moleculaire diagnostiek d.m.v. PCR
Fenotypische karakterisatie
Antilichaambepaling d.m.v. immuno- assay
+ 3 more
BS RHAEM LP 5 using Sysmex
BS RHAEM LP 4 & BS RHAEM LP 10
BS RHAEM LP6 / LP 9 using Glass
BS RHAEM LP 1 using thick film
BS RHAEM LP 6 & BS RHAEM LP 8
+ 3 more
Serum Detection of: | ** Documented in h
Urine Detection and quantification of re
Urine Detection and quantification of re
Urine Isolation and characterisation of
Urine Detection of | SOP MICRO-VIR-LP-6
+ 3 more
Paediatric Audiology | Ling 6
Pure Tone Audiometry
Tympanometry
Impression Taking
Hearing Aid Fitting
+ 3 more
No matching labs found.