ISO 10816-3
Industrial Machine Vibration Assessment (>15 kW)
ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.
What it measures
- Vibration velocity in mm/s (RMS) on bearing pedestals
- Measurement at specified speed ranges and operating conditions
- Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
- Vertical and horizontal vibration components
- Trend analysis and transient response
🇩🇪
DIN EN ISO 10816-1
🇬🇧
BS EN ISO 10816-1
🇫🇷
NF EN ISO 10816-1
🇮🇹
UNI EN ISO 10816-1
🇪🇸
UNE EN ISO 10816-1
🇳🇱
NEN EN ISO 10816-1
🇩🇪
DIN EN ISO 20816-3
🇬🇧
BS EN ISO 20816-3
🇫🇷
NF EN ISO 20816-3
🇮🇹
UNI EN ISO 20816-3
🇪🇸
UNE EN ISO 20816-3
🇳🇱
NEN EN ISO 20816-3
1,817
Accredited labs
19
Countries
Showing 1,476–1,500 of 1,817 labs
Taupunkttemperatur
Railway braking — urban guided transport
Widerstandssensor
–40 °C bis
> 5 °C bis
+ 3 more
Gleichspannung 0 mV
Messgeräte 10 mV
Wechselspannung 0,22 mV
> 220 mV
> 2,2 V
+ 3 more
Teslab Srl
Active
DIN EN 55014-1: 2018
DIN EN 50155
IEC 61000-4-16: 2015
DIN EN 61326-2-6
IEC 61326-1: 2012
+ 3 more
Test-Fuchs, Fritz Fuchs Gesellschaft mit beschränkter Haftung Kalibrierlaboratorium Deutschland
Active
Positiver Überdruck p e
> 70 bar
Überdruck p
(ein- oder mehrgängige
Testo Industrial Services
Active
- Gleichspannung
/ Messgeräte
Quellen
Hochspannung
- Gleichstromstärke
+ 3 more
Testo Industrial Services
Active
RELATIVE HUMIDITY
HUMIDITY continued
loggers
Gas Pressure Gauge
Saturated salt capsules
+ 2 more
Testzentrum Baden
Active
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-52
DIN EN IEC 60068-2
IEC 60512-11-6
DIN EN 50090-2-2: 2007
+ 3 more
Tetra Tech Consulting
Active
(HSG 248) – 2021
RPSCA1 based on HSG 248
(PCM) based on HSG 248
RPSCA2 based on HSG 248
BS 7592:2008, BS 8554:2015
+ 2 more
TetraTec Instruments
Active
Railway brakes — disc brake pads (UIC 54
Volumendurchfluss bzw.
0,01 m
Railway pantographs — requirements for m
39 mL/h
+ 3 more
The Auditing Company
Active
#EN ISO 5164:14
# EN 116-97
# ISO 13736
NEN 4400-1
#ISO 6618
DC CURRENT
DC Resistance
Measurement
DC VOLTAGE
CAPACITANCE
+ 3 more
(HSG 248) – 2021
03 based on HSG 248)
QOP01 based on HSG 248
(PCM) based on HSG 248
The Original Gauge Company
Active
LENGTH
Screw ring gauges (parallel)
LENGTH cont.
As for Involute Spline Gauges
See Note 2
+ 3 more
The Testing Lab
Active
DIN EN 933-11
BS EN ISO 17892-1:2014+A1:2022
BS EN ISO 17892-10:2018
BS EN ISO 17892-11:2019
BS EN ISO 17892-2:2014
+ 3 more
Thermo Electron LED
Active
- Gleichspannung
Messgeräte 0,001 V bis
0,33 V bis
3,3 V bis
330 V bis
+ 3 more
ISO 834-9:2003Cor1 :2009
ASTM E648 -23
BS 476-20
BS 476-21
IS/ISO 834-9
+ 3 more
Thomas Dudley
Active
BS 1212-2:1990 Clause 4
BS 1212-3:1990 Clause 4
DIN EN 997
Laktoseintoleranz (LCT -14055
BS 1212-4:1991 Clause 4, 13, 14
No matching labs found.