ISO 10816-3
Industrial Machine Vibration Assessment (>15 kW)
ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.
What it measures
- Vibration velocity in mm/s (RMS) on bearing pedestals
- Measurement at specified speed ranges and operating conditions
- Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
- Vertical and horizontal vibration components
- Trend analysis and transient response
🇧🇪
NBN EN ISO 10816-1
🇩🇪
DIN EN ISO 10816-1
🇬🇧
BS EN ISO 10816-1
🇫🇷
NF EN ISO 10816-1
🇮🇹
UNI EN ISO 10816-1
🇪🇸
UNE EN ISO 10816-1
🇳🇱
NEN EN ISO 10816-1
🇧🇪
NBN EN ISO 20816-3
🇩🇪
DIN EN ISO 20816-3
🇬🇧
BS EN ISO 20816-3
🇫🇷
NF EN ISO 20816-3
🇮🇹
UNI EN ISO 20816-3
4,140
Accredited labs
21
Countries
Showing 1,501–1,525 of 4,140 labs
Geolab
Active
DIN EN ISO 15587-2
DIN EN ISO 10523
ISO 10523
NF EN ISO-15587-2
NF EN ISO 15587-2 et NF EN ISO 11885
+ 3 more
ISO
ISO 21527-1
DIN EN ISO 1133-1
DIN EN ISO 1183-1
DIN EN ISO 527-3
+ 3 more
ISO 21527-1
ISO 21527-2
DIN EN 932-1
DIN EN 932-2
DIN EN 933-1
+ 3 more
Geproter Soc. Coop.
Active
DIN EN 12880
DIN EN ISO 11885
DIN EN ISO 10304-1
DIN EN 1484
DIN EN 14039
+ 3 more
Gerico Lab Srl
Active
ETSI EN 319 401
ETSI EN 319 411-1
ETSI EN 319 411-2
ETSI EN 319 412
Gerinnungszentrum Rhein-Ruhr
Active
HbA1c
Retikulozyten
Thrombozyten
Thrombinzeit
Folsäure
+ 3 more
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Active
Bauart wie GR 1482
und VDI/VDE 2604
- PiM rs6647, PiZ rs28929474, rs17580
CD23, CD25, CD33,CD34, CD38, CD59
P1433, P14-3-3
+ 3 more
Gestione Acqua SpA
Active
DIN EN ISO 10523
DIN EN ISO 10304-1
DIN EN ISO 17294-2
ISO 11731
DIN EN ISO 10304-4
+ 3 more
Ethanol
Digitoxin
HbA1c
Cortisol
Glucose
+ 3 more
abs
> 1001 bar
> 1000 bar
PRESSURE
DC Resistance
+ 3 more
Gigahertz Optik
Active
- Gleichstromstärke
/ Messgeräte
Niederfrequenz
spektrale
Bestrahlungsstärke
+ 3 more
EPPO PM 7/79 rev 2 2016/Cor 2017
EPPO PM 7/24 rev 5 2023 Appendix 5
EPPO PM 7/17 rev 3 2020 Appendix 4
EPPO PM 7/149 rev 1 2021/Cor 2023
IPPC FAO - ISPM 27 Annex 29 DP 29 2019
+ 2 more
Glasgow City Council
Active
ISO 11290-1
ISO 11290-2
ISO 21528-2
ISO 6579-1
ISO 4833-2
+ 3 more
Glenair UK
Active
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-13
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-6
+ 3 more
View Profile
Verified
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
Ethanol
Digoxin
Cortisol
Glucose
CEA
+ 3 more
MRSA
Hepatitis-B-surface-Antigen
Hepatitis B-e-Antigen
Mumps IgG
Hepatitis-A IgG
+ 3 more
Helicobacter pylori
Measurement
Collagen
Nuclear protein in lung and thyroid | Th
Detection of the following: | Special St
+ 3 more
Ethanol
Digoxin
Cortisol
Glucose
CEA
+ 3 more
Gontermann-Peipers
Active
DIN EN ISO 16810
DIN EN 13018
DIN EN ISO 945-1
DIN EN 1371-1
DIN EN 12680-3
+ 3 more
Gossen Metrawatt
Active
Railway brake handbooks (UIC 547)
- Gleichspannung
- Gleichstromstärke
- Gleichstromwiderstand
- Wechselspannung
+ 3 more
Gracci Laboratori
Active
DIN EN 13657
DIN EN 14346
DIN EN 14039
DIN EN 15934
DIN ISO 22036
+ 3 more
Granite Products (CI)
Active
TEMPERATURE
ROTATIONAL SPEED
ovens and similar apparatus
temperature sensor(s)
BS EN 12390-1:2021
+ 2 more
No matching labs found.