ISO 7626-2

Experimental Modal Analysis – Single-Point Excitation

ISO 7626-2 describes procedures for experimental modal analysis using single-point, single-axis excitation to characterise the dynamic properties and natural frequencies of structures and machines. This test method captures frequency response functions and mode shapes essential for structural design validation, vibration control, and fault diagnosis. Aerospace, automotive, civil engineering, and machinery manufacturers use modal analysis to refine designs and understand dynamic behaviour under operational loads. Accreditation ensures rigorous application of measurement protocols and data quality standards supporting engineering confidence in structural performance predictions.

What it measures

  • Frequency response functions (FRF) over specified frequency range
  • Natural frequencies (resonances) and modal damping ratios
  • Mode shapes and structural deflection patterns
  • Coherence and measurement quality indicators
  • Dynamic stiffness and impedance characteristics
🇩🇪 DIN EN ISO 7626-1 🇬🇧 BS EN ISO 7626-1 🇫🇷 NF EN ISO 7626-1 🇮🇹 UNI EN ISO 7626-1 🇪🇸 UNE EN ISO 7626-1 🇳🇱 NEN EN ISO 7626-1 🇩🇪 DIN EN ISO 7626-5 🇬🇧 BS EN ISO 7626-5 🇫🇷 NF EN ISO 7626-5 🇮🇹 UNI EN ISO 7626-5 🇪🇸 UNE EN ISO 7626-5 🇳🇱 NEN EN ISO 7626-5
1,817 Accredited labs
19 Countries

Showing 376–400 of 1,817 labs

DAkkS D-PL-17438-01-04 Stuttgart, DE
IEC 60335-1: 2010 IEC 60335-2-2 IEC 60335-2-3 DIN EN 60335-2-3: 2002 IEC 60335-2-4 + 3 more
View Profile
ENAC LE147 Campanillas, ES
IEC 61730-2 IEC 61215-1-2 IEC 61215-2 IEC 61215-1-3 IEC 61215-1-4 + 3 more
View Profile
ACCREDIA 00726 Zumpano - Frazione Zona industriale, IT
DIN EN 12457-2 AOAC 997.02 2000 DIN EN ISO 6888-2 DIN EN ISO 15587-1 ISO 4832 + 3 more
View Profile

DEUTA-WERKE

Active
DAkkS D-PL-12087-01-00 Bergisch Gladbach, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-21738-01-01 Köln, DE
- Gleichspannung Messgeräte > 330 mV > 3,3 V > 33 V > 330 V + 3 more
View Profile
UKAS 0138 Irlam, GB
Gas pressure (absolute) Gas pressure (gauge) Hydraulic pressure (gauge) Hydraulic Pressure (absolute) PRESSURE (cont’d) + 1 more
View Profile

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
COFRAC 1-6191 Grande Synthe, FR
NF EN ISO 6892-1 (méthode DIN EN 10164 ASTM E 8 ASTM A 370 DIN EN ISO 6508-1 + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile
COFRAC 1-7430 Marchaux-Chaudefontaine, FR
DIN EN 60068-2-64 DIN EN-60068-2-1 DIN EN 60068-2-78 DIN EN-60068-2-2 DIN EN 60068-2-14 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
UKAS 0143 Letchworth Garden City, GB
LENGTH Blade type Straight edges Surface plates External micrometer + 3 more
View Profile
DAkkS D-PL-11035-01-02 Essen, DE
ID136 > 140 DIN EN 143 DIN EN ISO 21149 DIN EN 13274-1 + 3 more
View Profile
DAkkS D-PL-11035-06-00 Essen, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
COFRAC 1-10039 Marseille, FR
NF X 43-050 NF X43-050 (parties ISO 22262-2 NF ISO 22262-1 et/ou ISO 22262-1
View Profile
COFRAC 1-10029 Colomiers, FR
NF X 43-050 NF X43-050 (parties
View Profile
COFRAC 1-10041 Villebon-Sur-Yvette, FR
NF X 46-032 NF X 43-050 NF X43-050 (parties
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile

No matching labs found.

Industries

Aerospace and defence engineering Automotive design and validation Civil engineering and bridge design Heavy machinery and equipment development Vibration and noise control consulting

Related Standards

  • ISO 7626-1 Vibration and shock—Experimental determination of mechanical mobility—Part 1: Basic definitions and transducers
  • ISO 7626-5 Vibration and shock—Experimental determination of mechanical mobility—Part 5: Coupling of mechanical mobility measurement instrumentation
  • ISO 6954 Mechanical vibration and shock—Acceleration transducers—Specifications for laboratory standard instruments

Other Test Methods

0 labs selected
Compare