ISO 7626-2

Experimental Modal Analysis – Single-Point Excitation

ISO 7626-2 describes procedures for experimental modal analysis using single-point, single-axis excitation to characterise the dynamic properties and natural frequencies of structures and machines. This test method captures frequency response functions and mode shapes essential for structural design validation, vibration control, and fault diagnosis. Aerospace, automotive, civil engineering, and machinery manufacturers use modal analysis to refine designs and understand dynamic behaviour under operational loads. Accreditation ensures rigorous application of measurement protocols and data quality standards supporting engineering confidence in structural performance predictions.

What it measures

  • Frequency response functions (FRF) over specified frequency range
  • Natural frequencies (resonances) and modal damping ratios
  • Mode shapes and structural deflection patterns
  • Coherence and measurement quality indicators
  • Dynamic stiffness and impedance characteristics
🇩🇪 DIN EN ISO 7626-1 🇬🇧 BS EN ISO 7626-1 🇫🇷 NF EN ISO 7626-1 🇮🇹 UNI EN ISO 7626-1 🇪🇸 UNE EN ISO 7626-1 🇳🇱 NEN EN ISO 7626-1 🇩🇪 DIN EN ISO 7626-5 🇬🇧 BS EN ISO 7626-5 🇫🇷 NF EN ISO 7626-5 🇮🇹 UNI EN ISO 7626-5 🇪🇸 UNE EN ISO 7626-5 🇳🇱 NEN EN ISO 7626-5
1,591 Accredited labs
17 Countries

Showing 701–725 of 1,591 labs

DAkkS D-ML-13450-02-01 Würzburg, DE
Fazio-skapulo-humerale DSC2, DSG2, DSP, JUP, PKP2, TMEM43 ); SN Myopathie-Panel; SNV Myotone Dystrophie Typ 1 / M. Curschmann-Steinert (DMPK) + 3 more
View Profile
DAkkS D-ML-13355-03-00 Stuttgart, DE
Thrombozytenfunktion Antiepileptika: Benzodiazepine, Fentanyl Ethylglucuronid, Ethylsulfat Ciclosporin, Tacrolimus, Everolimus + 3 more
View Profile
DAkkS D-ML-13355-04-00 Stuttgart, DE
Zelldifferenzierung HLA Klasse I Antikörper Crossmatch (serologische Verträglichkeitsprobe im HLA-System) Serologische HLA-Klasse-I-Typisierung + 3 more
View Profile
DAkkS D-ML-13295-05-00 München, DE
HLA-Antikörpertestung (Detektion) HLA-Klasse I und II HLA-Antikörper (Spezifizierung) HLA-Antikörper Screening HLA-Antikörperdifferenzierung + 3 more
View Profile
DAkkS D-ML-13295-04-00 München, DE
Thromboplastinzeit) Thrombozytenfunktion 10-OH-Carbazepin 5-Hydroxyindolessigsäure (5-HIES) + 3 more
View Profile
DAkkS D-ML-13295-04-01 München, DE
Lamotrigin AFP HbA1c CA 125 AMH + 3 more
View Profile
DAkkS D-ML-13295-01-01 München, DE
Kleines Blutbild Differentialblutbild maschinell C-reaktives Protein (CRP) Differentialblutbild manuell Urinstatus + 3 more
View Profile
DAkkS D-ML-13295-03-00 München, DE
17-OH-Progesteron ACTH Androstendion Aldosteron Anti-TG Antikörper + 3 more
View Profile
DAkkS D-ML-13421-01-00 Ludwigshafen, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu CDT Ampicilin Cefepim + 3 more
View Profile
DAkkS D-ML-13136-01-01 Augsburg, DE
Rhythmusstörungen (ABCC9, AKAP9, ANK2,TT MSH2, MSH6, MUTYH, PMS2, PTEN, RAD51C, R Familiärer Brust- und Eierstockkrebs MSH2, MSH6, EPCAM ); SNV, CNV Birt-Hogg-Dubé-Syndrom (FLCN + 3 more
View Profile
DAkkS D-ML-13400-01-00 Groß Grönau, DE
AMA M2-3E IgG Anti-CCP (Cyclische Citrullin Antikörper) IgG Anti-dsDNS-NCX IgG Anti- Transglutaminase + 3 more
View Profile
DAkkS D-K-17518-01-01 Remscheid, DE
abweichungen Metrosoft CM und Messvolumen Metrosoft QUARTIS, mit einer Software der Fa. WENZEL Raumdiagonale Metromec Chur, CH von ≤ 4666 mm
View Profile
DAkkS D-K-15098-01-01 Leonberg, DE
Software von WENZEL einer Raumdiagonalen Messprojektoren einer Raumdiagonalen Koordinatenmessgeräte geräte mit einem Messmikroskope ≤ 600 mm Auswertesoftware Messvolumen mit + 2 more
View Profile
DAkkS D-PL-17382-02-00 München, DE
UIC-Mb 541-03 UIC-541-08 UIC-541-6 DIN 27205-9 DIN EN 15355 + 3 more
View Profile
DAkkS D-K-15077-01-00 Aschaffenburg, DE
Parallelendmaße 0,5 mm bis DIN EN ISO 3650:1999 Parallelendmaße aus 0,5 mm bis Keramik oder Wolframkarbid nach + 3 more
View Profile
DAkkS D-K-22877-01-01 Eschweiler, DE
(ein- und mehrgängige zylindrische Außen- und geradlinigen Flanken und symmetrischem Profil sowie positiven Flankenwinkeln) + 3 more
View Profile
UKAS 23015 Mansfield, GB
and Appendix 3 of HSG 227 (2004)) Appendix 5 of HSG 227 (2004))
View Profile
DAkkS D-PL-22819-01-00 Lüdenscheid, DE
DIN 40050-9 IEC 60068-2-2 IEC 60068-2-6 DIN EN IEC 60068-2-13 DIN EN 60068-2-14 + 3 more
View Profile
UKAS 7736 Chelmsford, GB
(HSG 248) – 2021 (PCM) based on HSG 248 SAS 02 based on HSG 248
View Profile

Kovia

Active
UKAS 9942 Royal William Yard, GB
Appendix 5 of HSG 227 (2004)) HSG 227 (2004) HSG 264 (2012) and Appendix 3 of
View Profile
DAkkS D-ML-13173-01-00 Bad Oeynhausen, DE
Thrombozytenfunktion Amiodaron/Desethylamiodaron Cotinin Cyclosporin A Everolimus + 3 more
View Profile
DAkkS D-ML-21357-01-00 Heppenheim, DE
Albumin Alkohol ALP Anti-Faktor Xa (Fragmin) AT3 + 3 more
View Profile
DAkkS D-PL-21175-01-01 Hasbergen, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-PL-19181-01-00 Winnenden, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN EN 13487 DIN 45635-46 + 2 more
View Profile
DAkkS D-K-15009-01-01 Leipzig, DE
Eindringkörper für 75° Sound system equipment — speech transmis Länge der Schnittlinien * Vergrößerungsnormale Abflachung bis 300 + 3 more
View Profile

No matching labs found.

Industries

Aerospace and defence engineering Automotive design and validation Civil engineering and bridge design Heavy machinery and equipment development Vibration and noise control consulting

Related Standards

  • ISO 7626-1 Vibration and shock—Experimental determination of mechanical mobility—Part 1: Basic definitions and transducers
  • ISO 7626-5 Vibration and shock—Experimental determination of mechanical mobility—Part 5: Coupling of mechanical mobility measurement instrumentation
  • ISO 6954 Mechanical vibration and shock—Acceleration transducers—Specifications for laboratory standard instruments

Other Test Methods

0 labs selected
Compare