ISO 7626-5
Experimental Modal Analysis Using Impact Excitation
This test method characterises the dynamic properties of structures through experimental modal analysis using impact hammer excitation. The method measures natural frequencies, damping ratios, and mode shapes by striking the structure and recording the resulting vibration response. It is widely used in aerospace, automotive, civil engineering, and mechanical equipment development to validate structural designs and identify potential vibration issues. Accreditation ensures proper instrumentation calibration, correct measurement methodology, and reliable data interpretation for safety-critical applications.
What it measures
- Natural frequencies (modal frequencies)
- Damping ratios (modal damping)
- Mode shapes (displacement patterns)
- Frequency response functions (FRF)
- Coherence and data quality metrics
🇩🇪
DIN EN ISO 7626-1
🇬🇧
BS EN ISO 7626-1
🇫🇷
NF EN ISO 7626-1
🇮🇹
UNI EN ISO 7626-1
🇪🇸
UNE EN ISO 7626-1
🇳🇱
NEN EN ISO 7626-1
🇩🇪
DIN EN ISO 7626-2
🇬🇧
BS EN ISO 7626-2
🇫🇷
NF EN ISO 7626-2
🇮🇹
UNI EN ISO 7626-2
🇪🇸
UNE EN ISO 7626-2
🇳🇱
NEN EN ISO 7626-2
1,591
Accredited labs
17
Countries
Showing 651–675 of 1,591 labs
Intona
Active
and Appx. 3 of HSG 227 (2004))
Executive guides HSG 264 (2012)
(HSG 264, 2012)
Inventronics
Active
IEC 60068-2-78
ISO 20653
IEC 61000-4-4: 2012
DIN EN 60598-1
IEC 60068-2-14
+ 3 more
Irccos Srl
Active
IEC 60512-15-5
DIN EN 13116
DIN EN 13049
DIN EN 14019
DIN EN 1026
+ 3 more
Isserstedt Prüfmaschinen
Active
Härte* 20 HRA
Härtevergleichsplatten
20 HRB
20 HRC
40 HRD
+ 3 more
J B-Monitor
Active
(HSG 248) – 2021
No 1 based on HSG 248 – 2021
(PCM) based on HSG 248 – 2021
No 3 based on HSG 248 – 2021
(PCM) based on HSG 248
+ 1 more
JCS Technology
Active
ISO 178
BS 5350:Part C13
BS 2782 Part 10 Method 1005
BS EN ISO 14125
MIL-STD 810G:2008 Method 501.5
+ 3 more
Rillentiefe Pt und d 0,15 µm
Tiefeneinstellnormalen
> 12 µm
Rauheit auf
Geometrienormalen
+ 3 more
UNE 320001
ISO/IEC 18045
ISO/IEC 15408
CEM ISO
ISO/IEC 24759
+ 2 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-4: 2012
VDE 0847-4-4
IEC 61000-4-5: 2005
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
Innen- und Tiefenmaße
Konventioneller
+ 2 more
Javer Labs
Active
MIL-STD-810G, Method 508:7
BS 2011:2.1 Ca:1977
(IEC 60068-2-10:2005+A1:2018,
MIL-STD-810H, Method 508:8
Ebenheitsabweichung
verkörperungen z.B.
platten nach DIN 876:1984
Geradheitsabweichung
ebener Flächen, z.B.
+ 3 more
Johnson and Allen
Active
DC CURRENT
INSPECTION EQUIPMENT
AC CURRENT 50 Hz RMS
uncertainties may be increased.
Johs. Boss
Active
Außengewinde
Flankendurchmesser 3 mm bis 100 mm
0,5 mm bis 6 mm)
unsymmetrischem Profil
schiedlichen Ausgabeständen gestattet.
+ 3 more
MIL-PRF-46103E
DIN EN ISO 15106-3
DIN EN ISO 1522
DIN EN ISO 1523
ISO 16935:2007
+ 3 more
CD45 Percp+CD16+56+CD3
CD4
CD45 Percp+CD4+CD8
Adalimumab
Anti-Adalimumab Antikörper
+ 3 more
DIN EN 13346
DIN EN 27888
DIN 38404
DIN EN 26777
DIN 38405-24
+ 3 more
K. A. Schmersal
Active
DIN EN IEC 60947-5
IEC 60947-5-1
IEC 60947-5-2
DIN EN 60947-5
IEC 60947-5-3
+ 3 more
KB Prüftechnik
Active
Härteprüfmaschinen nach 100 HBW
Brinell- und
226 HBW
messeinrichtungen von
Härteprüfmaschinen
+ 3 more
KEMA
Active
IEC 60034
IEC 60034-2-1
IEC 60034-18-1
IEC 60034-4-1
IEC 60034-27-1
+ 3 more
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
EN IEC 62311
DIN EN IEC 60068-2-11
+ 3 more
basophile, eosinophile, Granulozyten
Differenzialblutbild
Erythrozyten
Erythrozytenverteilungsbreite
(RDW)
+ 3 more
KP Acoustics Research Labs
Active
BS EN ISO 10140-2:2021
ISO 3745
ISO 7171
IEC 60601-1
accordance with BS EN ISO 5349-1
DIN 4150-1
DIN 4150-2
DIN 4150-3
No matching labs found.