ISO 2631-1
Whole-Body Vibration Exposure Assessment
ISO 2631-1 establishes methods for measuring and evaluating human exposure to whole-body vibration in vehicles, buildings, and occupational environments. This test quantifies vibration acceleration over frequency ranges relevant to human physiology, assessing potential health effects and comfort levels. Industries including transportation, construction, and industrial manufacturing rely on this assessment to ensure worker safety and product quality. Accreditation ensures reliable measurement data for compliance with occupational health directives and product design standards across Europe.
What it measures
- Vibration acceleration in three orthogonal axes (X, Y, Z)
- Frequency-weighted vibration magnitude (1–80 Hz)
- Daily vibration exposure index (A(8))
- Peak acceleration and crest factor
- Comfort and health effect zones
🇩🇪
DIN EN ISO 2631-2
🇬🇧
BS EN ISO 2631-2
🇫🇷
NF EN ISO 2631-2
🇮🇹
UNI EN ISO 2631-2
🇪🇸
UNE EN ISO 2631-2
🇳🇱
NEN EN ISO 2631-2
🇩🇪
DIN EN ISO 5349-1
🇬🇧
BS EN ISO 5349-1
🇫🇷
NF EN ISO 5349-1
🇮🇹
UNI EN ISO 5349-1
🇪🇸
UNE EN ISO 5349-1
🇳🇱
NEN EN ISO 5349-1
1,591
Accredited labs
17
Countries
Showing 76–100 of 1,591 labs
ITC
Active
UNE-EN ISO 10545-2
UNE-EN ISO 10545-3
ASTM C373
UNE-EN ISO 10545-4
UNE-EN ISO 10545-5
+ 3 more
AIMEN
Active
UNE-EN ISO 3452-1
UNE-EN ISO 5817
UNE-EN ISO 23277
UNE-EN ISO 10042
UNE-EN ISO 13919-1
+ 3 more
0 mV ≤ U < 200 mV 0,2 V ≤ U < 2 V 2 V ≤
1 mV ≤ U < 220 mV 0,22 V ≤ U < 2,2 V 2,2
0 mV ≤ U ≤ 100 mV 0,1 V < U ≤ 1 V 1 V <
0 μA ≤ I < 200 μA 0,2 mA ≤ I < 2 mA 2 mA
0 μA ≤ I < 220 μA 0,22 mA ≤ I < 2,2 mA 2
+ 3 more
UNE-EN 772-11
UNE 136029
DIN 4772:1979
DIN EN 16510-2-4
DIN EN 17539
+ 3 more
IEC 15408-1
IEC 18045
IEC 18367
IEC 20543
IEC 20004
EPA 26
UNE-EN 15259
UNE-EN 14791
UNE-EN 13284-1
UNE EN 1911
+ 3 more
AUMOVIO Germany
Active
ISO 11451-1
ISO 11451-2: 2015
ISO 11451-4: 2013
ISO 11452-1
ISO 11452-2: 2019
+ 3 more
AUMOVIO Germany
Active
ISO 11452-2: 2019
ISO 11452-4: 2020
ISO 11452-5: 2002
ISO 11452-8: 2015
ISO 10605
+ 3 more
AWE
Active
(HSG 248) – 2021
LQP007 based on HSG 248
LQP003 based on HSG 248
(PCM) based on HSG 248
the guidance of GPG 14
PERSONAL DOSE EQUIVALENT:
RESPONSE:
Absolute Calibration
Active
DC Resistance
CFH-Gen, Macula-Degeneration
DC RESISTANCE (continued)
DC VOLTAGE
DC VOLTAGE (continued)
+ 3 more
Acorn Analytical Services
Active
(HSG 248) – 2021
(PCM) based on HSG 248
staining based on HSG 248
(HSG 264, 2012)
Appendix 5 of HSG 227
ISO 11654
BS EN ISO 10140-2:2021
ISO 7171
ISO 354
BS EN ISO 10140-3:2021
+ 3 more
Sound Calibrators
Pistonphones
based:
level
Microphones
+ 2 more
DIN EN ISO 11127-6
DIN EN 13727
1) BS EN ISO 11930:2019+
2) QMIC WI 22, based on BS EN
Taupunkttemperatur
Railway braking — urban guided transport
Temperaturtransmitter
Widerstandssensor *)
–30 °C
+ 3 more
Air Surveys
Active
(HSG 248) – 2021
APP 7 based on HSG 248
(PCM) based on HSG 248
(PCM) based on HSG 248)
APP 15 based on HSG 248
+ 2 more
BS EN ISO 16283-1:2014+A1:2017BS EN ISO
BS EN ISO 140-4:1998
ISO 1407
ISO 7171
BS EN ISO 9972:2015
+ 1 more
(HSG 248) – 2021
AEC 1 based on HSG 248
(PCM) based on HSG 248
AEC 6 based on HSG 248
Airbus Defence and Space
Active
- Gleichspannung
/ Messgeräte
1 µV
Quellen
> 1 V
+ 3 more
Airtech Analysis
Active
(HSG 248) – 2021
(PCM) based on HSG 248
staining based on HSG 248
(HSG 264, 2012)
Appendix 5 of HSG 227 (2004))
No matching labs found.