VDA Band 19.1
Technical cleanliness and particle contamination analysis
VDA Band 19.1 is a German automotive industry standard that defines cleanliness requirements and testing procedures for functionally relevant components in fluid circuits. It specifies sampling methods, particle extraction techniques, and contamination classification compatible with ISO 4406 codes. This standard is widely used by Tier 1 suppliers and OEMs in Germany and central Europe to verify component integrity before assembly. Accreditation to this standard demonstrates laboratory competence in precise particle quantification and adherence to stringent German automotive quality expectations.
What it measures
- Particle count and size classification (ISO 4406 compatible)
- Cleanliness class of functional components
- Surface contamination of injectors, valves, and pumps
- Acceptable contamination thresholds per application
- Particle morphology and composition
🇩🇪
DIN EN ISO 16232
🇬🇧
BS EN ISO 16232
🇫🇷
NF EN ISO 16232
🇮🇹
UNI EN ISO 16232
🇪🇸
UNE EN ISO 16232
🇳🇱
NEN EN ISO 16232
🇩🇪
DIN EN ISO 4406
🇬🇧
BS EN ISO 4406
🇫🇷
NF EN ISO 4406
🇮🇹
UNI EN ISO 4406
🇪🇸
UNE EN ISO 4406
🇳🇱
NEN EN ISO 4406
1,865
Accredited labs
17
Countries
Showing 1,026–1,050 of 1,865 labs
Laboratorio Bucciarelli
Active
UNI 10591
ISO 17604
AOAC 2012.01 2016
UNI 10590
ISO 14698-1
+ 3 more
Laboratorio Catara
Active
EPA 6020
DIN EN 12457-2
BS EN 15662
DIN EN ISO 6888-1
EPA 3015
+ 3 more
BS EN 15662
DIN EN ISO 6888-1
AOAC 2012.01 2016
DIN EN ISO 15213-2
ISO 4832
+ 3 more
ISO 6888-1
ISO 6888-2
DIN EN ISO 10304-1
BS EN 12697-13:2017
ISO 14189
+ 3 more
ISO 17604
ISO 18787
BS EN 15662
AOAC 2012.01 2016
BS 7889:1997 (withdrawn)
+ 3 more
Basophile Granulozyten
Eosinophile Granulozyten
Erythrozyten
Hämatokrit
Leukozyten
+ 3 more
Laborgemeinschaft Köln
Active
Liste aller Untersuchungsverfahren im fl
Webpräsenz des Medizinischen Laboratoriu
HbA1c
Basophile
Basophile absolut
+ 3 more
Laborgemeinschaft Odenwald
Active
HbA1c
Großes Blutbild
Kleines Blutbild
Retikulocyten
Natriumchlorid
+ 3 more
DIN EN ISO 7027-1 (C 21)
DIN EN 27888 (C 8)
DIN EN ISO 9308-1 (K 12)
DIN EN ISO 7393-2 (G 4-2)
DIN EN ISO 16266 (K 11)
+ 3 more
Laborärzte Sindelfingen
Active
Ristocetin Kofactor Aktivität
Willibrand Faktors
a-Hydroxy-Alprazolam
Amilsulprid
7-amino-Flunitrazepam
+ 3 more
Ladisa
Active
ISO 6888-1
ISO 18787
BS EN 15662
AOAC 2012.01 2016
DIN EN ISO 10304-1
+ 3 more
Lambda Calibration
Active
PRESSURE (cont’d)
Distortion Factor
Spot frequency
Phase angle
(Herpes simplex virus type
+ 3 more
Lambeth Scientific Services
Active
(HSG 248) – 2021
(PCM) based on HSG 248
P-12 based on HSG 248
(HSG 248) – 2021
(PCM) based on HSG 248
ISO 12966-2
F06 6 & F06 5 based on BS EN
F05 4 based on BS 770:Part
+ 3 more
DIN EN 16174
DIN CEN ISO/TS 16179
DIN EN 15933
DIN ISO 15178
DIN EN 15936
+ 3 more
GPT
GOT
GGT
Salmonellen
Shigellen
+ 3 more
DIN EN 1622 (B 3)
DIN EN ISO 7887 (C 1)
DIN EN ISO 7027-1 (C 21)
DIN EN 27888 (C 8)
DIN EN ISO 9308-1 (K 12)
+ 3 more
Laore Sardegna
Active
ISO 4833-1
ISO 16649-2
ISO 6888-2
DIN EN ISO 11290-1
ISO 6579-1
+ 3 more
Leadec BV &
Active
Gleichspannung 33 mV
Messgeräte 0,33 V
330 V
Gleichstromstärke 33 µA
Messgeräte 0,33 mA
+ 3 more
Leftfield Environmental
Active
(HSG 248) – 2021
LSOP6 based on HSG 248
(PCM) based on HSG 248
(ein- und mehrgängige
zylindrische Außen- und
symmetrischem und
unsymmetrischem Profil)
Außengewinde
+ 3 more
DIN EN 60601-2-4
IEC 60512-4-1
DIN EN 124-2
IEC 60512-4-3
DIN EN 60601-2-44
+ 3 more
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-3 (A 21)
DIN EN ISO 19458 (K 19)
DIN EN 1622 (B 3)
+ 3 more
Les Préleveurs Indépendants
Active
DIN ISO 17289
ISO 5667-9 (hors échant.
DIN EN ISO 7027-2
NF X 31-615 (Uniquement
DIN EN ISO 10523
+ 3 more
No matching labs found.